169 resultados para Guicciardini, Francesco.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The research of new catalysts for the hydrogen production described in this thesis was inserted within a collaboration of Department of Industrial Chemistry and Materials of University of Bologna and Air Liquide (Centre de Recherche Claude-Delorme, Paris). The aim of the work was focused on the study of new materials, active and stable in the hydrogen production from methane, using either a new process, the catalytic partial oxidation (CPO), or a enhanced well-established process, the steam methane reforming (SMR). Two types of catalytic materials were examined: 1) Bulk catalysts, i.e. non-supported materials, in which the active metals (Ni and/or Rh) are stabilized inside oxidic matrix, obtained from perovskite type compounds (PVK) and from hydrotalcite type precursors (HT); 2) Structured catalysts, i.e. catalysts supported on materials having high thermal conductivity (SiC and metallic foams). As regards the catalytic partial oxidation, the effect of the metal (Ni and/or Rh), the role of the metal/matrix ratio and the matrix formulation of innovative catalysts obtained from hydrotalcite type precursors and from perovskites were examined. In addition, about steam reforming process, the study was carried out first on commercial type catalysts, examining the deactivation in industrial conditions, the role of the operating conditions and the activity of different type of catalysts. Then, innovative materials bulk (PVK and HT) and structured catalysts (SiC and metallic foam) were studied and a new preparation method was developed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study of electrochemiluminescence (ECL) involves photophysical and electrochemical aspects. Excited states are populated by an electrical stimulus. The most important applications are in the diagnostic field where a number of different biologically-relevant molecules (e.g. proteins and nucleic acids) can be recognized and quantified with a sensitivity and specificity previously not reachable. As a matter of fact the electrochemistry, differently to the classic techniques as fluorescence and chemiluminescence, allows to control the excited state generation spatially and temporally. The two research visits into A. J. Bard electrochemistry laboratories were priceless. Dr. Bard has been one of ECL pioneers, the first to introduce the technique and the one who discovered in 1972 the surprising emission of Ru(bpy)3 2+. I consider necessary to thank by now my supervisors Massimo and Francesco for their help and for giving me the great opportunity to know this unique science man that made me feel enthusiastic. I will never be grateful enough… Considering that the experimental techniques of ECL did not changed significantly in these last years the most convenient research direction has been the developing of materials with new or improved properties. In Chapter I the basics concepts and mechanisms of ECL are introduced so that the successive experiments can be easily understood. In the final paragraph the scopes of the thesis are briefly described. In Chapter II by starting from ECL experimental apparatus of Dr. Bard’s laboratories the design, assembly and preliminary tests of the new Bologna instrument are carefully described. The instrument assembly required to work hard but resulted in the introduction of the new technique in our labs by allowing the continuation of the ECL studies began in Texas. In Chapter III are described the results of electrochemical and ECL studies performed on new synthesized Ru(II) complexes containing tetrazolate based ligands. ECL emission has been investigated in solution and in solid thin films. The effect of the chemical protonation of the tetrazolate ring on ECL emission has been also investigated evidencing the possibility of a catalytic effect (generation of molecular hydrogen) of one of the complexes in organic media. Finally, after a series of preliminary studies on ECL emission in acqueous buffers, the direct interaction with calf thymus DNA of some complexes has been tested by ECL and photoluminescence (PL) titration. In Chapter IV different Ir(III) complexes have been characterized electrochemically and photophysically (ECL and PL). Some complexes were already well-known in literature for their high quantum efficiency whereas the remaining were new synthesized compounds containing tetrazolate based ligands analogous to those investigated in Chapt. III. During the tests on a halogenated complex was unexpectedly evidenced the possibility to follow the kinetics of an electro-induced chemical reaction by using ECL signal. In the last chapter (V) the possibility to use mono-use silicon chips electrodes as ECL analitycal devices is under investigation. The chapter begins by describing the chip structure and materials then a signal reproducibility study and geometry optimization is carried on by using two different complexes. In the following paragraphs is reported in detail the synthesis of an ECL label based on Ru(bpy)3 2+ and the chip functionalization by using a lipoic acid SAM and the same label. After some preliminary characterizations (mass spectroscopy TOF) has been demonstrated that by mean of a simple and fast ECL measurement it’s possible to confirm the presence of the coupling product SAM-label into the chip with a very high sensitivity. No signal was detected from the same system by using photoluminescence.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PREMESSA: La progressione della recidiva d’epatite C è accelerata nei pazienti sottoposti a trapianto di fegato e ciò ha portato alla necessità di sviluppare nuove e validate metodiche non invasive per la quantificazione e la misura della fibrosi epatica. SCOPI: Stabilire l’efficacia dell’elastometria epatica (Fibroscan®) e dei parametri sierici di fibrosi, attualmente disponibili nella pratica clinica, per predire il grado di fibrosi nei pazienti sottoposti a trapianto epatico. METODI: La correlazione fra fibrosi epatica, determinata mediante biopsia epatica ed esame istologico, e Fibroscan® o indici clinico-sierologici di fibrosi (Benlloch, Apri, Forns, Fibrotest and Doppler resistance index), è stata studiata in pazienti che avevano ricevuto un trapianto ortotopico di fegato con evidenza di recidiva d’epatite da HCV. Un totale di 36 pazienti, con la seguente classificazione istologica: fibrosi secondom METAVIR F1=24, F2=8, F3=3, F4=1, sono stati arruolati nella popolazione oggetto di studio. Un totale di 29 individui volontari sani sono serviti come controllo. Le differenze fra gli stadi di fibrosi sono state calcolate mediante analisi statistica non parametrica. Il miglior cut-off per la differenziazione di fibrosi significativa (F2-F4) è stato identificato mediante l’analisi delle curve ROC. RISULTATI: La rigidità epatica ha presentato valori di 4.4 KPa (2.7-6.9) nei controlli (mediane e ranges), con valori in tutti i soggeti <7.0 KPa; 7.75 KPa (4.2-28.0) negli F1; 16.95 KPa (10.2-31.6) negli F2; 21.10 KPa nell’unico paziente F4 cirrotico. Le differenze sono state statisticamente significative per i soggetti controllo versus F1 e F2 (p<0.0001) e per F1 versus F2 (p<0.0001). Un cut-off elastografico di 11.2 KPagarantisce 88% di Sensibilità, 90% di Specificità, 79% di PPV e 95% di NPV nel differenziare i soggetti F1 dagli F2-F4. Le AUROC, relativamente alla capacità di discriminare fra i differenti gradi di fibrosi, evidenziavano un netto vantaggio per il Fibroscan® rispetto ad ognuno degli indici non invasivi di fibrosi. CONCLUSIONI: L’elastometria epatica presenta una buona accuratezza diagnostica nell’identificare pazienti con fibrosi epatica di grado significativo, superiore a quella di tutti gli altri test non invasivi al momento disponibili nella clinica, nei pazienti portatori di trapianto epatico ortotopico da cadavere con recidiva di HCV.