46 resultados para Mini-scale method
em Reposit
Resumo:
A small-scale method was developed for the simultaneous determination of γ-HCH, heptachlor, aldrin, dicofol, mirex, endosulfan I, endosulfan II and endosulfan sulphate in soil. The extraction and clean-up steps were combined into one step by transferring soil samples to chromatographic columns prepacked with neutral alumina. The pesticides elution was processed with n-hexane : dichloromethane (7:3) and the concentrated eluate was analysed using gas-liquid chromatography with electron capture detection. Analyses of the in vitro fortified samples with the selected pesticides were performed at three different levels. Mean recoveries for aldrin, γ-HCH and heptachlor, at levels of 2, 10 and 20 ng/g, ranged from 71 to 87%; for dicofol, at levels of 8, 40 and 80 ng/g, ranged from 97 to 103%; for endosulfan I and II, at levels of 5, 25 and 50 ng/g, ranged from 88 to 96%; for mirex, at levels of 6, 30 and 60 ng/g, ranged from 86 to 110%; and for endosulfan sulphate, at levels of 15, 75 and 150 ng/g, ranged from 93 to 104%. The method can be used for rapid determination of these pesticides in soil. © Springer-Verlag 1996.
Resumo:
Herbicidas tais como trifluralina, simazina, atrazina, metribuzina e metolaclor são usados na agricultura brasileira. A eficiência de um método em pequena escala para a determinação destes herbicidas e dois produtos de degradação em amostras de solo foi avaliada. Os compostos foram extraídos das amostras de solo (5 g) com 20 ml de acetato de etila em agitador mecânico por 50 min. Após a extração, o sobrenadante foi filtrado em sulfato de sódio anidro, concentrado e analisado por cromatografia a gás de alta resolução com detector termiônico específico. Valores médios de recuperação obtidos de amostras de solo fortificadas em três níveis diferentes variaram de 81 a 115 % com valores de desvio padrão relativo entre 1,2 e 12,7 %. Os limites de detecção do método variaram de 0,01 a 0,06 mg kg-1. A metodologia foi aplicada a amostras de solo de fazendas localizadas próximas à cidade de Araraquara, estado de São Paulo, Brasil.
Resumo:
OBJETIVO: Analisar, comparativamente, a obtenção minimamente invasiva com o uso do MINI-HARVEST® e com instrumental tradicional adaptado. MÉTODO: de junho de 1996 a janeiro de 1999, 63 pacientes submetidos à cirurgia de revascularização do miocárdio tiveram suas veias safenas retiradas segundo técnica minimamente invasiva. Nos 30 primeiros pacientes da série utilizou-se método de visão direta com auxílio de dois afastadores de Langenbeck, e nos 33 restantes utilizou-se o MINI-HARVEST®. RESULTADOS: A idade média dos pacientes era de 61 ± 8,75 anos, sendo 52 homens e 11 mulheres. Quarenta e cinco pacientes eram diabéticos, 45 apresentavam sobrepeso/obesidade, 25 eram tabagistas ativos, 32 apresentavam história pregressa de infarto do miocárdio. O tempo médio de retirada da veia safena com afastadores Langenbeck foi de 34,2 ± 8,14 minutos e com o MINI-HARVEST® de 39,20 ± 9,12 minutos. A extensão de veia retirada foi similar nos dois grupos, variando de 10 a 30 cm. Houve uma deiscência superficial no grupo com afastadores de Langenbeck. Houve necessidade de reversão para método tradicional de retirada em dois casos do grupo MINI-HARVEST® e um do grupo Langenbeck. A incidência de infarto transoperatório foi 4,5% (três) no grupo Langenbeck e 3,1%(dois) no grupo MINI-HARVEST®. CONCLUSÕES: Podemos concluir que o método de obtenção de veia safena minimamente invasivo sob visão direta é efetivo e seguro, tanto com o uso de instrumentos tradicionais adaptados para este fim, como com afastadores especialmente constituídos, ressaltando-se que o MINI-HARVEST® dispensa a presença de um auxiliar.
Resumo:
In the present study an evaluation was made of a method for the determination of organochlorine pesticide residues in ethoxylated lanolin. Samples were homogenized with Celite, transferred to chromatographic columns, prepacked with silica gel deactivated to 10%. The pesticide elution was processed with n-hexane-dichloromethane and the concentrated eluate was analyzed using gas-liquid chromatography (GC) with electron capture detection (ECD). The composition of the elution solvent was a significant factor for the recovery of the pesticides. Mean recoveries obtained for fortified samples ranged from 87 to 94% for p,p'-DDE, dieldrin, endrin, p,p'-DDD and p,p'-DDT. Optimization of the experimental conditions resulted in a small-scale method that combines extraction and cleanup in a single step. (C) 2000 Elsevier B.V. S.A. All rights reserved.
Resumo:
By using the multiple scale method with the simultaneous introduction of multiple times, we study the propagation of long surface-waves in a shallow inviscid fluid. As a consequence of the requirements of scale invariance and absence of secular terms in each order of the perturbative expansion, we show that the Korteweg-de Vries hierarchy equations do play a role in the description of such waves. Finally, we show that this procedure of eliminating secularities is closely related to the renormalization technique introduced by Kodama and Taniuti. © 1995 American Institute of Physics.
Resumo:
By considering the long-wavelength limit of the regularized long wave (RLW) equation, we study its multiple-time higher-order evolution equations. As a first result, the equations of the Korteweg-de Vries hierarchy are shown to play a crucial role in providing a secularity-free perturbation theory in the specific case of a solitary-wave solution. Then, as a consequence, we show that the related perturbative series can be summed and gives exactly the solitary-wave solution of the RLW equation. Finally, some comments and considerations are made on the N-soliton solution, as well as on the limitations of applicability of the multiple-scale method in obtaining uniform perturbative series.
Resumo:
After the prohibition of organochlorine-pesticide use in Brazil for controlling insect vector diseases, Mato Grosso State gathered the exceeding DDT and stored it irregularly in an open air area that belongs to the National Health Foundation, causing soil contamination. This study aimed to evaluate the contamination level and dissipation of p,p′-DDT and p,p′-DDE in this area. For that, surface soil samples were collected on 19 September 2000, 15 December 2000, 4 April 2001 and soil samples 30-40 cm; 60-70 cm and 90-100 cm deep were taken from five points in the studied area on 17 July 2001. The contaminants were determined by a small scale method which consists on extraction and clean-up steps combined into one step by transferring soil samples mixed with neutral alumina to a chromatographic column prepacked with neutral alumina and elution with hexane:dichloromethane (7:3 v:v). The eluate was concentrated and the analytes were quantified by gas chromatography with an electron-capture detector. p,p′-DDT at surface soil ranged from 3800 to 7300 mg kg -1. 30-40 cm deep soil sample concentrations varied from 0.036 to 440 mg kg -1 while 90-100 cm deep samples varied from 0.069 to 180 mg kg -1. Volatilization is probably the main dissipation process. The p,p′-DDT is moving slowly downward in the soil profile, however, the levels of this contaminant are high enough to present risk to underground waters. © 2005 Elsevier Ltd. All rights reserved.
Resumo:
In this work we analyze the convergence of solutions of the Poisson equation with Neumann boundary conditions in a two-dimensional thin domain with highly oscillatory behavior. We consider the case where the height of the domain, amplitude and period of the oscillations are all of the same order, and given by a small parameter e > 0. Using an appropriate corrector approach, we show strong convergence and give error estimates when we replace the original solutions by the first-order expansion through the Multiple-Scale Method.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
This paper presents an interior point method for the long-term generation scheduling of large-scale hydrothermal systems. The problem is formulated as a nonlinear programming one due to the nonlinear representation of hydropower production and thermal fuel cost functions. Sparsity exploitation techniques and an heuristic procedure for computing the interior point method search directions have been developed. Numerical tests in case studies with systems of different dimensions and inflow scenarios have been carried out in order to evaluate the proposed method. Three systems were tested, with the largest being the Brazilian hydropower system with 74 hydro plants distributed in several cascades. Results show that the proposed method is an efficient and robust tool for solving the long-term generation scheduling problem.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The ionospheric effect is one of the major errors in GPS data processing over long baselines. As a dispersive medium, it is possible to compute its influence on the GPS signal with the ionosphere-free linear combination of L1 and L2 observables, requiring dual-frequency receivers. In the case of single-frequency receivers, ionospheric effects are either neglected or reduced by using a model. In this paper, an alternative for single-frequency users is proposed. It involves multiresolution analysis (MRA) using a wavelet analysis of the double-difference observations to remove the short- and medium-scale ionosphere variations and disturbances, as well as some minor tropospheric effects. Experiments were carried out over three baseline lengths from 50 to 450 km, and the results provided by the proposed method were better than those from dual-frequency receivers. The horizontal root mean square was of about 0.28 m (1 sigma).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)