67 resultados para Method of Failure Mode and Effect and Criticality Analysis

em Reposit


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to analyze the effects of exercise mode on the validity of onset of blood lactate accumulation (OBLA-3.5-mM fixed blood lactate concentration) to predict the work-rate at maximal lactate steady state (MLSSwork-rate). Eleven recreationally active mates (21.3 +/- 2.9 years, 72.8 +/- 6.7 kg, 1.78 +/- 0.1 m) performed randomly incremental tests to determine OBLA (stage duration of 3 min), and 2 to 4 constants work-rate exercise tests to directly determine maximal lactate steady state parameters on a cycle-ergometer and treadmill. For both exercise modes, the OBLA was significantly correlated to MLSSwork-rate, (cycling: r = 0.81 p = 0.002; running: r = 0.94, p < 0.001). OBLA (156.2 +/- 41.3 W) was lower than MLSSwork-rate (179.6 +/- 26.4 W) during cycling exercise (p = 0.007). However, for running exercise, there was no difference between OBLA (3.2 +/- 0.6 m s(-1)) and MLSSwork-rate (3.1 +/- 0.4 m s(-1)). The difference between OBLA and MLSSworkrate on the cycle-ergometer (r = 0.86; p < 0.001) and treadmill (r = 0.64; p = 0.048) was significantly related to the specific MLSS. We can conclude that the validity of OBLA on predicting MLSSwork-rate is dependent on exercise mode and that its disagreement is related to individual variations in MLSS. (C) 2007 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The purpose of this study was to evaluate the surfaces of commercially pure titanium (cp Ti) implants modified by laser beam (LS), without and with hydroxyapatite deposition by the biomimetic method (HAB), without (HAB) and with thermal treatment (HABT), and compare them with implants with surfaces modified by acid treatment (AS) and with machined surfaces (MS), employing topographical and biomechanics analysis. Methods: Forty-five rabbits received 75 implants. After 30, 60, and 90 days, the implants were removed by reverse torque and the surfaces were topographically analyzed. Results: At 30 days, statistically significant difference (P < 0.05) was observed among all the surfaces and the MS, between HAB/HABT and AS and between HAB and LS. At 60 days, the reverse torque of LS, HAB, HABT, and AS differed significantly from MS. At 90 days, difference was observed between HAB and MS. The microtopographic analysis revealed statistical difference between the roughness of LS, HAB, and HABT when compared with AS and MS. Conclusions: It was concluded that the implants LS, HAB, and HABT presented physicochemical and topographical properties superior to those of AS and MS and favored the osseointegration process in the shorter periods. In addition, HAB showed the best results when compared with other surfaces. © 2012 John Wiley & Sons A/S.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trata-se de estudo qualitativo, utilizando-se como referencial metodológico a Grounded Theory e como referencial teórico o Processo de Trabalho em Enfermagem, para compreender o papel assumido pelo enfermeiro perante as normas e rotinas hospitalares, relativas aos familiares visitantes e acompanhantes de adultos e idosos internados em um Hospital Universitário. A análise dos dados permitiu a identificação do tema: definindo-se a modalidade de apoio familiar durante a hospitalização, que reúne duas categorias principais: tornando-se familiar visitante e tornando-se familiar acompanhante. Por meio da análise, pôde-se aprofundar a compreensão do quanto as regras estabelecidas, com o objetivo de disciplinar e tornar eficiente o trabalho desenvolvido no hospital, podem explicitar o desprovimento de autonomia no processo de trabalho, para modificar as relações nesse contexto e o quanto a apropriação do familiar como parte da equipe de saúde, está distante de ser pensada no concreto das instituições.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Enfermagem (mestrado profissional) - FMB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contents This study aimed to evaluate the sonographic characteristics of the udder and teats and to determine the Doppler indexes of mammary artery in healthy and undergoing subclinical and clinical mastitis goats. Thirty animals among Saanen and Alpine Brown goats were arranged in three groups, healthy goats (HG), goats with subclinical mastitis (SMG) and goats with clinical mastitis (CMG). Using the B-mode, the sonographic characteristics (echotexture and echogenicity) and biometry (diameter and area of the udder cistern, diameter and area of the teat cistern and thickness of the teat wall) were evaluated. Using Doppler ultrasonography, the vascular indexes of the mammary artery were obtained. It was observed hyperechogenicity with solid component in the gland cistern when comparing animals with clinical mastitis and healthy mammary tissue. Regarding the echotexture of the breast tissue, there was heterogeneity in the mammary parenchyma on the three groups, for the milk, it was observed homogeneity for animals on HG and SMG and heterogeneity for animals on CMG. Grey-scale quantitative assessment revealed increase in echogenicity (mean value) for all the structures when comparing the three groups. Biometry did not reveal statistical difference between groups, for none of the evaluated structures. Doppler examination of the mammary artery showed the decrease of end diastolic velocity and raise of pulsatility index between groups. The association of B-mode and Doppler ultrasonography is useful for the evaluation of the udder of dairy goats with mastitis. It is a sensitive and specific method for the study of this disease. Doppler mode was unable to establish reliable criteria for diagnosis of subclinical mastitis. Moreover, the quantification of echogenicity is a useful technique for the evaluation of the milk in animals with mastitis; therefore, it is suggested that it can be used as complementary technique for the diagnosis of mastitis in goats.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To describe the prevalence of hysteroscopic findings and histologic diagnoses inpatients with abnormal uterine bleeding (AUB).Design: Retrospective series of consecutive patients.Setting: Tertiary care University hospital and private office.Patient(s): Four thousand fifty-four hysteroscopies with biopsy in patients with AUB evaluated between June 1993 and December 2004.Intervention(S): Hysteroscopies were performed using 2.9-mm or 4-mm telescopes with CO2 or saline as the distension media. Biopsies were (lone with a 5-mm grasper or with a Novak's curette.Main Outcome Measure(s): Prevalence of hysteroscopic findings and histologic analysis of biopsies.Result(S): Endometrial polyp was the most frequent hysteroscopic finding, accounting for 1,374 (33.9%) cases. Normal uterine cavity and cervical canal were found in 814 (20.1%) patients. Submucous fibroids were diagnosed in 302 (7.5%) women. Normal endometrium was the most frequent histologic diagnosis, accounting for 1,888 (46.6%) cases. Endometrial polyp was found in 1, 115 (27.5%) patients. Endometrial hyperplasia was diagnosed in 613 (15.1%) and endometrial cancer in 105 (2.6%) women.Conclusion(s): Endometrial polyps are the most frequent hysteroscopic findings in patients with AUB, whereas normal endometrium is the most frequent histologic diagnosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This study evaluated the reliability and failure modes of implants with a microthreaded or smooth design at the crestal region, restored with screwed or cemented crowns. The postulated null hypothesis was that the presence of microthreads in the implant cervical region would not result in different reliability and strength to failure than smooth design, regardless of fixation method, when subjected to step-stress accelerated life-testing (SSALT) in water. Materials and methods: Eighty four dental implants (3.3 × 10 mm) were divided into four groups (n = 21) according to implant macrogeometric design at the crestal region and crown fixation method: Microthreads Screwed (MS); Smooth Screwed (SS); Microthreads Cemented (MC), and Smooth Cemented (SC). The abutments were torqued to the implants and standardized maxillary central incisor metallic crowns were cemented (MC, SC) or screwed (MS, SS) and subjected to SSALT in water. The probability of failure versus cycles (90% two-sided confidence intervals) was calculated and plotted using a power law relationship for damage accumulation. Reliability for a mission of 50,000 cycles at 150 N (90% 2-sided confidence intervals) was calculated. Differences between final failure loads during fatigue for each group were assessed by Kruskal-Wallis along with Benferroni's post hoc tests. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The Beta (β) value (confidence interval range) derived from use level probability Weibull calculation of 1.30 (0.76-2.22), 1.17 (0.70-1.96), 1.12 (0.71-1.76), and 0.52 (0.30-0.89) for groups MC, SC, MS, and SS respectively, indicated that fatigue was an accelerating factor for all groups, except for SS. The calculated reliability was higher for SC (99%) compared to MC (87%). No difference was observed between screwed restorations (MS - 29%, SS - 43%). Failure involved abutment screw fracture for all groups. The cemented groups (MC, SC) presented more abutment and implant fractures. Significantly higher load to fracture values were observed for SC and MC relative to MS and SS (P < 0.001). Conclusion: Since reliability and strength to failure was higher for SC than for MC, our postulated null hypothesis was rejected. © 2012 John Wiley & Sons A/S.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)