144 resultados para Intensity-Modulated

em Reposit


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Low-density polyethylene (LDPE) was characterised for its dielectric and electrical properties before and after chemical treatment. A reduction in the permittivity and dielectric loss was observed in the polymer after treatment with hexane. The intensity in the Raman Spectrum in the disordered longitudinal acoustic mode region (DLAM) also was reduced due to a hexane treatment. Using thermally stimulated discharge current (TSDC) and laser-intensity-modulated method (LIMM) techniques it was observed that charge injection can be enhanced in the polymer matrix in the empty sites, created by the removal of the low molecular weight impurities with chemical treatment. (C) 2002 Kluwer Academic Publishers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A performance comparison between a recently proposed novel technique known as fast orthogonal frequency-division multiplexing (FOFDM) and conventional orthogonal frequency-division multiplexing (OFDM) is undertaken over unamplified, intensity-modulated, and direct-detected directly modulated laser-based optical signals. Key transceiver parameters, such as the maximum achievable transmission capacity and the digital-to-analog/analog-to-digital converter (DAC/ADC) effects are explored thoroughly. It is shown that, similarly to conventional OFDM, the least complex and bandwidth efficient FOFDM can support up to similar to 20 Gb/s over 500 m worst-case multimode fiber (MMF) links having 3 dB effective bandwidths of similar to 200 MHz X km. For compensation of the DAC/ADC roll-off, a power-loading (PL) algorithm is adopted, leading to an FOFDM system improvement of similar to 4 dB. FOFDM and conventional OFDM give similar optimum DAC/ADC parameters over 500 m worst-case MMF, while over 50 km single-mode fiber a maximum deviation of only similar to 1 dB in clipping ratio is observed due to the imperfect chromatic dispersion compensation caused by one-tap equalizers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Social conflict between mice produces analgesia in the attacked mouse. Both the magnitude and type (opioid or nonopioid) of this analgesia have been related to attack intensity and strain of mouse. In the present study low intensity social conflict (7 bites) did not produce analgesia, whereas high intensity - 30 and 60 bites interactions produced, respectively, short-lasting (5 min) and very short-lasting (1 min) analgesia in Swiss albino mice, when compared with nonaggressive interaction (0 bite). The 30 bites aggressive interaction induced analgesia (AIIA) was not affected by IP injection of either naloxone (5.0 and 7.5 mg/kg) or diazepam (0.5, 1.0, 2.0 and 4.0 mg/kg). However, this attack-induced analgesia was reduced after IP administration of the 5-HT1A agonists, gepirone (0.3 and 3.0 mg/kg) and BAY R 1531 (0.01 mg/kg). These results indicate that the analgesia induced by 30 bites social conflict in Swiss albino mice does not involve opioid and GABA-benzodiazepine (GABA-BZD) mechanisms. In addition, they suggest that high-intensity social conflict activates serotonergic pain modulatory systems that act through 5-HT1A receptors. Copyright (C) 1997 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Animals show behavioral and physiological changes that emerge in response to environmental perturbations (i.e., emergency life-history stages). In this study, we investigate the effects of light intensity on aggressive encounters and social stability in groups of adult male Nile tilapia, Oreochromis niloticus (Linnaeus, 1758). The study compared the behavior observed under low (280.75 ± 50.60 lx) and high (1394.14 ± 520.32 lx) light intensities, with 12 replicates for each treatment. Adult fish were isolated in 36-L aquaria for 96 hours, and three males were grouped for 11 days in 140-L aquaria. Agonistic behavior was video-recorded (10 min/day) on the 3rd, 5th, 7th, and 9th day to quantify aggressive interactions and social stability. There was an effect of light intensity and day of observation on the total number of agonistic behaviors performed by the fish group. Besides, increased frequency of aggressive interactions (the sum of the four sessions) by the alpha, beta and gamma fish occurred at the higher light intensity. The dominance ranks of the fish remained unchanged across the observation sessions under both the low and high light intensities. We concluded that enhanced light intensity has a cumulative effect that increases the aggressiveness of the Nile tilapia but that this effect is not sufficiently strong to destabilize the social hierarchy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente estudo teve como objetivo comparar os níveis plasmáticos de glicose e cortisol de um grupo de eqüinos atletas submetidos ao esforço de longa duração (enduro eqüestre) em distâncias de 30 e 60km, com velocidades médias de 10 e 15km h-1, respectivamente. Os animais foram aleatoriamente separados em dois grupos, sendo que a um deles foi administrada, por via oral, uma pasta eletrolítica hipertônica antes, durante e após as referidas provas. O outro grupo foi usado como controle. Os resultados das concentrações de cortisol revelaram um aumento significativo, no primeiro momento, em que a intensidade do esforço era maior (15km/h), ou com a continuação deste (30km de distância), no segundo momento, para todos os grupos. Os resultados referentes à concentração de glicose permaneceram constantes durante a prova de 30km; entretanto, nos primeiros 20km da prova de 60km, tais resultados revelaram um aumento significativo no grupo controle, retornando a valores basais no momento subseqüente. A reposição eletrolítica tem a sua importância na manutenção do equilíbrio hidroeletrolítico e ácido básico e, no presente estudo, pode ter contribuído para a manutenção da concentração média de glicose plasmática.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the potential relationship between excess post-exercise oxygen consumption (EPOC), heart rate recovery (HRR) and their respective time constants (tvo(2) and t(HR)) and body composition and aerobic fitness (VO(2)max) variables after an anaerobic effort. 14 professional cyclists (age = 28.4 +/- 4.8 years, height = 176.0 +/- 6.7 cm, body mass = 74.4 +/- 8.1 kg, VO(2)max = 66.8 +/- 7.6 mL. kg(-1) . min(-1)) were recruited. Each athlete made 3 visits to the laboratory with 24h between each visit. During the first visit, a total and segmental body composition assessment was carried out. During the second, the athletes undertook an incremental test to determine VO(2)max. In the final visit, EPOC (15-min) and HRR were measured after an all-out 30s Wingate test. The results showed that EPOC is positively associated with % body fat (r = 0.64), total body fat (r = 0.73), fat-free mass (r = 0.61) and lower limb fat-free mass (r = 0.55) and negatively associated with HRR (r = - 0.53, p < 0.05 for all). HRR had a significant negative correlation with total body fat and % body fat (r = - 0.62, r = - 0.56 respectively, p < 0.05 for all). These findings indicate that VO(2)max does not influence HRR or EPOC after high-intensity exercise. Even in short-term exercise, the major metabolic disturbance due to higher muscle mass and total muscle mass may increase EPOC. However, body fat impedes HRR and delays recovery of oxygen consumption after effort in highly trained athletes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detector system that can measure X-ray intensity in the mammographic range of 22 to 36 kVp (equivalent photon energies ofthe beam between 11 and 15 keV) is presented. It consists of a lithium mobate detector and a high-sensitivity current-to-voltage converter.