81 resultados para the honors college

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

90.00% 90.00%

Publicador:

Resumo:

There is an increasing need for more accurate prognostic and predictive markers in veterinary oncology because of an increasing number of treatment options, the increased financial costs associated with treatment, and the emotional stress experienced by owners in association with the disease and its treatment. Numerous studies have evaluated potential prognostic and predictive markers for veterinary neoplastic diseases, but there are no established guidelines or standards for the conduct and reporting of prognostic studies in veterinary medicine. This lack of standardization has made the evaluation and comparison of studies difficult. Most important, translating these results to clinical applications is problematic. To address this issue, the American College of Veterinary Pathologists' Oncology Committee organized an initiative to establish guidelines for the conduct and reporting of prognostic studies in veterinary oncology. The goal of this initiative is to increase the quality and standardization of veterinary prognostic studies to facilitate independent evaluation, validation, comparison, and implementation of study results. This article represents a consensus statement on the conduct and reporting of prognostic studies in veterinary oncology from veterinary pathologists and oncologists from around the world. These guidelines should be considered a recommendation based on the current state of knowledge in the field, and they will need to be continually reevaluated and revised as the field of veterinary oncology continues to progress. As mentioned, these guidelines were developed through an initiative of the American College of Veterinary Pathologists' Oncology Committee, and they have been reviewed and endorsed by the World Small Animal Veterinary Association.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective - To investigate the use of the laryngeal mask airway (LMA) in dogs. Study Design - Prospective experimental study. Animals - Eight healthy adult mixed breed dogs weighing from 15 to 20 kg. Methods - The dogs were anesthetized with intravenous pentobarbital. An LMA was introduced after the induction of anesthesia and 1 L/min O2 plus 1 L/min air was delivered using a circle anesthetic system. Respiratory rate, tidal volume, arterial O2 saturation (pulse oximetry), end tidal CO2, inspired fraction of O2, pulse rate, and mean arterial blood pressure were measured after the insertion of the LMA and 30, 60, 90, and 120 minutes afterwards. Results - There were no changes in respiratory rate, tidal volume, arterial O2 saturation, and pulse rate during anesthesia. End tidal CO2 decreased significantly by the end of anesthesia and ventilation appeared satisfactory. Conclusions - An LMA appeared to be an alternative option to maintain the patency of the airway in dogs. Clinical Relevance - This device may allow safe maintenance of an airway in dogs when intubation is difficult or when it interferes with the procedure (eg, cervical myelography). ©Copyright 1999 by The American College of Veterinary Surgeons.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective - To evaluate the effect of changing the mode of ventilation from spontaneous to controlled on the arterial-to-end-tidal CO2 difference [P(a-ET)CO2] and physiological dead space (VD(phys)/VT) in laterally and dorsally recumbent halothane-anesthetized horses. Study Design - Prospective, experimental, nonrandomized trial. Animals - Seven mixed breed adult horses (1 male and 6 female) weighing 320 ± 11 kg. Methods - Horses were anesthetized in 2 positions - right lateral and dorsal recumbency - with a minimum interval of 1 month. Anesthesia was maintained with halothane in oxygen for 180 minutes. Spontaneous ventilation (SV) was used for 90 minutes followed by 90 minutes of controlled ventilation (CV). The same ventilator settings were used for both laterally and dorsally recumbent horses. Arterial blood gas analysis was performed every 30 minutes during anesthesia. End-tidal CO2 (PETCO2) was measured continuously. P(a-ET)CO2 and VD(phys)/VT were calculated. Statistical analysis included analysis of variance for repeated measures over time, followed by Student-Newman-Keuls test. Comparison between groups was performed using a paired t test; P < .05 was considered significant. Results - P(a-ET)CO2 and VD(phys)/VT increased during SV, whereas CV reduced these variables. The variables did not change significantly throughout mechanical ventilation in either group. Dorsally recumbent horses showed greater P(a-ET)CO2 and VD(phys)/VT values throughout. PaCO2 was greater during CV in dorsally positioned horses. Conclusions and Clinical Relevance - Changing the mode of ventilation from spontaneous to controlled was effective in reducing P(a-ET)CO2 and physiological dead space in both laterally and dorsally recumbent halothane-anesthetized horses. Dorsal recumbency resulted in greater impairment of effective ventilation. Capnometry has a limited value for accurate estimation of PaCO, in anesthetized horses, although it may be used to evaluate pulmonary function when paired with arterial blood gas analysis. © Copyright 2000 by The American College of Veterinary Surgeons.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: Potential effects on hardness and roughness of a necessary and effective disinfecting regimen (1% sodium hypocholorite and 4% chlorhexidine) were investigated for two hard chairside reline resins versus a heat-polymerizing denture base acrylic resin. Materials and Methods: Two standard hard chairside reliners (Kooliner and Duraliner II), one heat-treated chairside reliner (Duraliner II +10 minutes in water at 55°C), and one standard denture base material (Lucitone 550) were exposed to two disinfecting solutions (1% sodium hypochlorite; 4% chlorhexidine gluconate), and tested for two surface properties [Vickers hardness number (VHN, kg/mm2); Roughness (Ra, μm)] for different times and conditions (1 hour after production, after 48 hours at 37 ± 2°C in water, after two disinfection cycles, after 7 days in disinfection solutions, after 7 days in water only). For each experimental condition, eight specimens were made from each material. Data were analyzed by analysis of variance followed by Tukey's test, and Student's t-test (p= 0.05). Results: For Kooliner (from 6.2 ± 0.3 to 6.5 ± 0.5 VHN) and Lucitone 550 (from 16.5 ± 0.4 to 18.4 ± 1.7 VHN), no significant changes in hardness were observed either after the disinfection or after 7 days of immersion, regardless of the disinfectant solution used. For Duraliner II (from 4.0 ± 0.1 to 4.2 ± 0.1 VHN), with and without heat treatment, a small but significant increase in hardness was observed for the specimens immersed in the disinfectant solutions for 7 days (from 4.3 ± 0.2 to 4.8 ± 0.5 VHN). All materials showed no significant change in roughness (Kooliner: from 0.13 ± 0.05 to 0.48 ± 0.24 μm; Duraliner II, with and without heat treatment: from 0.15 ± 0.04 to 0.29 ± 0.07 μm; Lucitone 550: from 0.44 ± 0.19 to 0.49 ± 0.15 μm) after disinfection and after storage in water for 7 days. Conclusions: The disinfectant solutions, 1% sodium hypochlorite and 4% chlorhexidine gluconate, caused no apparent damage on hardness and roughness of the materials evaluated. Copyright © 2006 by The American College of Prosthodontists.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: This study evaluated the ultimate tensile strength of a tissue conditioner without nystatin incorporation (GI - control group) and the same tissue conditioner modified by the addition of nystatin in two concentrations: GII - 500,000 International Units (U) and GIII - 1,000,000 U, in which each milligram of the medicament corresponded to 6079 U. Materials and Methods: Dumbbell-shaped specimens (N = 7) with a central cross-sectional area of 33 × 6 × 3 mm were produced for the three experimental groups. After polymerization following manufacturer's instructions, specimens were immersed in distilled water at 37°C for either 24 hours or 7 days and then tested in tension in the MTS 810 at 40 mm/minute. Data were analyzed by two-way ANOVA followed by Tukey's test, at 95% level of confidence. Results: The means (force-grams (gf) ± standard deviation) of the ultimate tensile strength were: GI - 634.29 ± 122.80; GII - 561.92 ± 133.56; and GIII - 547.30 ± 73.47 for 24-hour storage, and GI - 536.68 ± 54.71; GII - 467.50 ± 143.51; and GIII - 500.62 ± 159.76 for 7-day storage. There were no statistically significant differences among the three experimental groups (p > 0.05). The ultimate tensile strength means of all experimental groups after 7 days were significantly lower than those observed after 24 hours (p = 0.04). Conclusions: The results of this study suggest that the addition of nystatin into the tissue conditioner investigated in concentrations below 1,000,000 U did not affect its ultimate tensile strength. Copyright © 2006 by The American College of Prosthodontists.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: Selecting artificial teeth for edentulous patients is difficult when pre-extraction records are not available. Various guidelines have been suggested for determining the width of the maxillary anterior denture teeth. This study was undertaken to evaluate the use of the nasal width as a guide for the selection of proper width maxillary anterior denture teeth in four racial groups of the Brazilian population. Materials and Methods: One hundred and sixty subjects (40 Whites, 40 Mulattos, 40 Blacks, and 40 Asians) were selected. Using a sliding caliper, the nasal width and the intercanine distance were measured. The Pearson product-moment correlation coefficient was used to determine the relationship between the above measurements. A prediction was made of the percentage of subjects of the White, Mulatto, Black, and Asian populations in which the selection error due to the clinical application of the method of the nasal width would be within 0 to 2 mm, within 2 to 4 mm, and greater than 4 mm. Results: The four racial groups showed a weak correlation between the intercanine distance and the nasal width. In 39.7% of the White, 55.7% of the Mulatto, 81.9% of the Black, and 48.2% of the Asian populations, errors greater than 4 mm would be present with the use of the nasal width. Conclusions: The correlation found between the intercanine distance and the nasal width was not high enough to be used as a predictive factor. The relationship between natural tooth width and artificial tooth width as predicted by the nasal width showed that the nasal width method is not accurate for all the studied groups. Copyright © 2006 by The American College of Prosthodontists.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of disinfection treatments with chemical solutions (2% glutaraldehyde, 5% sodium hypochlorite, and 5% chlorhexidine) and microwave energy on the hardness of four long-term soft denture liners. Materials and Methods: Forty rectangular specimens of four soft lining materials (Molloplast-B, Ufi Gel P, Eversoft, and Mucopren soft) were made for each material. Ten samples of each material were immersed in different disinfectant solutions for 10 minutes or placed in a microwave oven for 3 minutes at 500 W. The hardness values were obtained with a Shore A durometer, before the first disinfection cycle (control), and also after two cycles of disinfection. Data were submitted to analysis of variance and Tukey's test (p < 0.01). Results: The highest value of hardness was obtained for Molloplast-B, independent of the disinfection technique. Mucopren soft demonstrated intermediate values and Ufi Gel P and Eversoft the lowest values of Shore A hardness. For Molloplast-B, the disinfection using glutaraldehyde demonstrated the highest value of hardness. The number of disinfections had no effect on the hardness values for all the materials studied and disinfection techniques. Conclusions: The application of two disinfection cycles did not change the Shore A hardness values for all the materials. The glutaraldehyde solution demonstrated the highest values of Shore A hardness for the Molloplast-B, Mucopren soft, and Ufi Gel P materials, while Eversoft did not present any differences in hardness when submitted to different disinfection treatments. Copyright © 2007 by The American College of Prosthodontists.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: The effect of water immersion on the shear bond strength (SBS) between 1 heat-polymerizing acrylic resin (Lucitone 550-L) and 4 autopolymerizing reline resins (Kooliner-K, New Truliner-N, Tokuso Rebase Fast-T, Ufi Gel Hard-U) was investigated. Specimens relined with resin L were also evaluated. Materials and Methods: One hundred sixty cylinders (20 × 20 mm) of L denture base resin were processed, and the reline resins were packed on the prepared bonding surfaces using a split-mold (3.5 × 5.0 mm). Shear tests (0.5 mm/min) were performed on the specimens (n = 8) after polymerization (control), and after immersion in water at 37°C for 7, 90, and 180 days. All fractured surfaces were examined by scanning electron microscopy (SEM) to calculate the percentage of cohesive fracture (PCF). Shear data were analyzed with 2-way ANOVA and Tukey's test; Kruskall-Wallis test was used to analyze PCF data (α = 0.05). Results: After 90 days water immersion, an increase in the mean SBS was observed for U (11.13 to 16.53 MPa; p < 0.001) and T (9.08 to 13.24 MPa, p = 0.035), whereas resin L showed a decrease (21.74 MPa to 14.96 MPa; p < 0.001). The SBS of resins K (8.44 MPa) and N (7.98 MPa) remained unaffected. The mean PCF was lower than 32.6% for K, N, and T, and higher than 65.6% for U and L. Conclusions: Long-term water immersion did not adversely affect the bond of materials K, N, T, and U and decreased the values of resin L. Materials L and U failed cohesively, and K, N, and T failed adhesively. © 2007 by The American College of Prosthodontists.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fracture of dentures is a common clinical finding in daily prosthodontic practice, resulting in great inconvenience to both patient and dentist. A satisfactory repair should be cost-effective, simple to perform, and quick; it should also match the original color and not cause distortion to the existing denture. Different repair materials, surface designs, and mechanical and chemical surface treatments have been recommended in order to obtain stronger repairs. This article reviews some of the available literature with regard to the most important factors that may influence the strength of denture repairs. © 2007 by The American College of Prosthodontists.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: This study evaluated the effectiveness of different exposure times of microwave irradiation on the disinfection of a hard chairside reline resin. Materials and Methods: Sterile specimens were individually inoculated with one of the tested microorganisms (Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans, and Bacillus subtilis) and incubated for 24 hours at 37°C. For each microorganism, 10 specimens were not microwaved (control), and 50 specimens were microwaved. Control specimens were individually immersed in sterile saline, and replicate aliquots of serial dilutions were plated on selective media appropriate for each organism. Irradiated specimens were immersed in water and microwaved at 650 W for 1, 2, 3, 4, or 5 minutes before serial dilutions and platings. After 48 hours of incubation, colonies on plates were counted. Irradiated specimens were also incubated for 7 days. Some specimens were prepared for scanning electron microscopic (SEM) analysis. Results: Specimens irradiated for 3, 4, and 5 minutes showed sterilization. After 2 minutes of irradiation, specimens inoculated with C. albicans were sterilized, whereas those inoculated with bacteria were disinfected. One minute of irradiation resulted in growth of all microorganisms. SEM examination indicated alteration in cell morphology of sterilized specimens. The effectiveness of microwave irradiation was improved as the exposure time increased. Conclusion: This study suggests that 3 minutes of microwave irradiation can be used for acrylic resin sterilization, thus preventing cross-contamination. © 2008 by The American College of Prosthodontists.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The dual path of insertion concept for removable partial denture (RPD) design may be used in esthetically demanding situations. When compared to conventional RPDs, the main advantage of this design is the minimal use of clasps. This clinical report describes the treatment of a patient with an anterior maxillary edentulous area using a dual path RPD. The diagnostic cast was surveyed to ensure the adequacy of the undercuts on the mesial surfaces of the anterior abutments, where rigid minor connectors were placed. Inverted V-shaped canine cingulum rest seats were prepared to provide resistance to tooth movement during function. The dual path RPD concept allows excellent esthetic results, minimizes tooth preparation, and reduces the tendency toward plaque accumulation in a Kennedy class IV partially edentulous arch. © 2008 by The American College of Prosthodontists.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effectiveness of disinfectant solutions (1% sodium hypochlorite, 2% chlorhexidine digluconate, 2% glutaraldehyde, 100% vinegar, tabs of sodium perborate-based denture cleanser, and 3.8% sodium perborate) in the disinfection of acrylic resin specimens (n = 10/group) contaminated in vitro by Candida albicans, Streptococcus mutans, S. aureus, Escherichia coli, or Bacillus subtilis as measured by residual colony-forming unit (CFU). In a separate experiment, acrylic resin was treated with disinfectants to monitor potential effects on surface roughness, Ra (μm), which might facilitate microbial adherence. Materials and Methods: Three hundred fifty acrylic resin specimens contaminated in vitro with 1×10 6 cells/ml suspensions of standard strains of the cited microorganisms were immersed in the disinfectants for 10 minutes; the control group was not submitted to any disinfection process. Final counts of microorganisms per ml were performed by plating method for the evaluation of microbial level reduction. Results were compared statistically by ANOVA and Tukey's test (p ≤ 0.05). In a parallel study aiming to evaluate the effect of the tested disinfectant on resin surface, 60 specimens were analyzed in a digital rugosimeter before and after ten cycles of 10-minute immersion in the disinfectants. Measurements of superficial roughness, Ra (μm), were compared statistically by paired t-test (p ≤ 0.05). Results: The results showed that 1% sodium hypochlorite, 2% glutaraldehyde, and 2% chlorhexidine digluconate were most effective against the analyzed microorganisms, followed by 100% vinegar, 3.8% sodium perborate, and tabs of sodium perborate-based denture cleanser. Superficial roughness of the specimens was higher after disinfection cycles with 3.8% sodium perborate (p = 0.03) and lower after the cycles with 2% chlorhexidine digluconate (p = 0.04). Conclusion: Within the limits of this experiment, it could be concluded that 1% sodium hypochlorite, 2% glutaraldehyde, 2% chlorexidine, 100% vinegar, and 3.8% sodium perborate are valid alternatives for the disinfection of acrylic resin. © 2008 by The American College of Prosthodontists.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a novel approach to the computed assessment of a mammographic phantom device. The approach shown here is fully automated and is based on the automatic selection of the region of interest, in the use of the discrete wavelet transform (DWT) and morphological operators to assess the quality of the American College of Radiology (ACR) mammographic phantom images. The algorithms developed here have succesfully scored 30 images obtained with different combinations of voltage applied to the tube and exposure and could notice the differences in the radiographs due to the different level of exposure to radiation. © 2013 Springer-Verlag.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: The objective of this study was to assess the use of analgesics, describe the attitudes of Brazilian veterinarians towards pain relief in horses and cattle and evaluate the differences due to gender, year of graduation and type of practice. Study design: Prospective survey. Methods: Questionnaires were sent to 1000 large animal veterinarians by mail, internet and delivered in person during national meetings. The survey investigated the attitudes of Brazilian veterinarians to the recognition and treatment of pain in large animals and consisted of sections asking about demographic data, use of analgesic drugs, attitudes to pain relief and to the assessment of pain. Descriptive statistics were used to analyze frequencies. Simple post hoc comparisons were performed using the chi-square test. Results: Eight hundred questionnaires were collected, but 87 were discarded because they were incomplete or blank. The opioid of choice for use in large animals was butorphanol (43.4%) followed by tramadol (39%). Flunixin (83.2%) and ketoprofen (67.6%) were the most frequently used NSAIDs by Brazilian veterinarians. Respondents indicated that horses received preoperative analgesics for laparotomy more frequently (72.9%) than cattle (58.5%). The most frequently administered preoperative drugs for laparotomy in horses were flunixin (38.4%) and xylazine (23.6%), whereas the preoperative drugs for the same surgical procedure in cattle were xylazine (31.8%) and the local administration of lidocaine (48%). Fracture repair was considered the most painful surgical procedure for both species. Most veterinarians (84.1%) believed that their knowledge in this area was not adequate. Conclusions and clinical relevance: Although these Brazilian veterinarians thought that their knowledge on recognition and treatment of pain was not adequate, the use of analgesic in large animals was similar in Brazil to that reported in other countries. © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective-To compare the pre-emptive analgesic effects of epidural ketamine or S(+)-ketamine on post-incisional hyperalgesia.Study Design-Prospective randomized study.Animals-Twenty-four mongrel dogs (1-5 years, weighing 11.9 +/- 1.8 kg).Methods-Dogs were anesthetized with propofol (5 mg/kg intravenously) and a lumbosacral epidural catheter was placed. Dogs were randomly allocated to 3 groups, each with 8 dogs. The control group (CG) was administered saline solution (0.3 mL/kg); the ketamine group (KG) ketamine (0.6 mg/kg); and the S(+)-ketamine group (SG) S(+)-ketamine (0.6 mg/kg). The final volume was adjusted to 0.3 mL/kg in all groups. Five minutes after the epidural injection a surgical incision was made in the common pad of the right hind limb and was immediately closed with simple interrupted nylon suture. Respiratory (RR) and heart (HR) rates, rectal temperature (7, sedation (S), lameness score, and mechanical nociceptive threshold by von Frey filaments were evaluated before the propofol anesthesia and at 15, 30, 45, 60, 75, and 90 minutes and then at 2, 4, 6, 8, 12, and 24 hours after epidural injection.Results-There were no differences in RR, HR, T, or S between groups. Motor blockade of the hind limbs was observed during 20 +/- 3.6 minutes in KG and during 30.6 +/- 7.5 minutes in SG (mean SD). Mechanical force applied to obtain an aversive response was higher from 45 minutes to 12 hours in KG and from 60 to 90 minutes in SG, when compared with CG.Conclusions-Pre-emptive epidural ketamine induced no alterations in RR and FIR, and reduced post-incisional hyperalgesia for a longer time than did S(+) ketamine.Clinical Relevance-Although anesthetic and analgesic potency of S(+) ketamine is twice that of ketamine, the racemic form is seemingly better for post-incisional hyperalgesia. (C) Copyright 2004 by the American College of Veterinary Surgeons.