14 resultados para television file

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

P>AimTo compare the efficacy of different digital radiographic imaging systems for determining the length of endodontic files.MethodologyK-type endodontic files were introduced into the canals of 40 extracted human permanent single-rooted teeth and fixed in place at random lengths. The teeth were radiographed using Digora Optime (R), CygnusRay MPS (R) and CDR Wireless (R) digital imaging systems. Six observers measured every file length in all the images and repeated this procedure in 50% of the image samples, and assigned a score to the level of difficulty found. Analysis of variance for differences between digital systems and Tukey's test were performed. The level of intraobserver agreement was measured by intraclass correlation. The assigned scores were evaluated by Kruskal-Wallis and Dunn's tests.ResultsThe CDR Wireless values did not differ significantly from the actual lengths and the CygnusRay MPS values. The Digora Optime system was significantly different from the others and overestimated the values (P < 0.05). The Digora Optime was significantly easier to use for taking measurements and the CygnusRay MPS the most difficult (P < 0.05). All digital radiographic imaging systems showed excellent agreement with the Intraclass Correlation Coefficient > 0.95.ConclusionsThe three digital radiographic imaging systems were precise. The CDR Wireless system was significantly more accurate in determining endodontic file lengths, and similarly to Digora Optime, was considered the least difficult to use when assessing endodontic file lengths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to simplify computer management, several system administrators are adopting advanced techniques to manage software configuration of enterprise computer networks, but the tight coupling between hardware and software makes every PC an individual managed entity, lowering the scalability and increasing the costs to manage hundreds or thousands of PCs. Virtualization is an established technology, however its use is been more focused on server consolidation and virtual desktop infrastructure, not for managing distributed computers over a network. This paper discusses the feasibility of the Distributed Virtual Machine Environment, a new approach for enterprise computer management that combines virtualization and distributed system architecture as the basis of the management architecture. © 2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The goal of this study was to evaluate the efficacy of the Self-Adjusting File (SAF) and ProTaper for removing calcium hydroxide [Ca(OH)2] from root canals. Material And Methods: Thirty-six human mandibular incisors were instrumented with the ProTaper system up to instrument F2 and filled with a Ca(OH)2-based dressing. After 7 days, specimens were distributed in two groups (n=15) according to the method of Ca(OH)2 removal. Group I (SAF) was irrigated with 5 mL of NaOCl and SAF was used for 30 seconds under constant irrigation with 5 mL of NaOCl using the Vatea irrigation device, followed by irrigation with 3 mL of EDTA and 5 mL of NaOCl. Group II (ProTaper) was irrigated with 5 mL of NaOCl, the F2 instrument was used for 30 seconds, followed by irrigation with 5 mL of NaOCl, 3 mL of EDTA, and 5 mL of NaOCl. In 3 teeth Ca(OH)2 was not removed (positive control) and in 3 teeth canals were not filled with Ca(OH)2 (negative control). Teeth were sectioned and prepared for the scanning electron microscopy. The amounts of residual Ca(OH)2 were evaluated in the middle and apical thirds using a 5-score system. Results: None of the techniques completely removed the Ca(OH)2 dressing. No difference was observed between SAF and ProTaper in removing Ca(OH)2 in the middle (P=0.11) and the apical (P=0.23) thirds. Conclusion: The SAF system showed similar efficacy to rotary instrument for removal of Ca(OH)2 from mandibular incisor root canals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were submitted to dynamic bending testing in stainless-steel simulated curved canals. Axial displacement of the simulated canals was performed with half of the instruments (n = 10), with back-and-forth movements in a range of 1.5 mm. Time until fracture was recorded, and the number of cycles until instrument fracture was calculated. Cyclic fatigue resistance was greater for reciprocating systems than for rotary systems (P < 0.05). Instruments from the Reciproc and WaveOne systems significantly differed only when axial displacement occurred (P < 0.05). Instruments of the ProTaper Universal and MTwo systems did not significantly differ (P > 0.05). Cyclic fatigue and torsional resistance were greater for reciprocating systems than for continuous rotary systems, irrespective of axial displacement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The social networks on the internet have experienced rapid growth and joined millions of users in Brazil and throughout the world. Such networks allow groups of people to communicate and exchange information. Sharing information in files is also a growing activity on the internet and is done in various ways. However, applications are not yet available to enable file sharing on Facebook, the premier social network today. This study aims to investigate how users use Facebook, and their practices for file sharing. Due to the experimental nature of this research, we opted for a data collection survey, applied over the web. From the data analysis, we have found a frequent use of file sharing, but no interest in paid services. As for Facebook, there was an extensive use of applications. The set of results shows a favourable scenario for applications that allow file sharing on Facebook.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lateral asymmetries are in everywhere as well as in all movements made by man, which become more evident in movements of sport. The asymmetry is particularly pointed out in futsal when players, even with clear opportunity of making use of their non-preferred foot, try to place the ball in order to execute the action with their preferred foot. The study of asymmetry in futsal is quite relevant, once ambidextrous players present advantages in their performances during a match, which can help futsal athletes not only in their performance improvement but also with the prescription of training. For this reason, the present study had questioned: is there symmetry/asymmetry at the performance of lower contralateral limbs during actions with the possession ball (pass, receiving a ball and kick into the goal) during a futsal match? Thus, the aim of this study was to analyze the symmetry/asymmetry using the preferred and non-preferred foot in actions with the possession ball (pass, receiving and shoot) in adult Futsal's players (professional). The winner team of eight matches of the 2012 FIFA Futsal World Cup was analyzed. An average of 75 players had all their actions (pass, receiving a ball and shot on goal) using their lower limbs during the match analyzed. However, their actions with the head and torso were not analyzed. The games were acquired through a television broadcast. All eight matches were followed by an appraiser through a computer. The Skout® software was used to collect the data, taking notes of the player involved, the type of action (pass, receiving a ball and shot on goal), its foot used (preferred or non-preferred foot) and if the execution was correct or wrong. These data were saved in a text file, in the form of a matrix and imported into the Matlab® software, where was analyzed the following parameters: frequency of occurrence of each action with each foot and quantity of correct and wrong occurrences performed with...