12 resultados para residential houses
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The Brazilian houses in wood are executed with several techniques and species, in function of the areas they are located, therefore, it is treated of regional traditional houses, built practically without modem technological resources. These houses are the ones of the tropical areas, where there is abundance of this material, or the ones of the south region, prevailing the European immigrant's constructive techniques. Nowadays, in the urbanized centers of the country it is observed that this type of house can be found sheltering the most lacking populations, in the slums; or in highly sophisticated residential units which are conceived and executed by specialist professionals for a social class of high purchasing power; or still, those that are marketed by companies of small load, that offer standardized residences, usually acquired by the middle class as second residence, in the field or in the coast. The work has for objective to study the houses of these companies that are consolidated at the market, identifying the constructive system, the product; as well as, its production process, trying to verify which technologies are incorporated to these processes. The analysis that was made allows a larger understanding of the product, wood house, that exists in the market and identification of the technological degree in the productive process of those constructive systems.
Resumo:
Esta pesquisa foi conduzida com o objetivo de avaliar diferentes tipos de coberturas em instalações para aves, por meio do Índice de Temperatura de Globo Negro e Umidade (ITGU), Carga Térmica de Radiação (CTR) e Entalpia (H). O experimento foi conduzido na Universidade Estadual de Goiás, entre os meses de abril e maio de 2011, sendo composto por cinco tratamentos (coberturas): CA -Telha de cimento-amianto; BA -Telha de bambu; BAP -Telha de bambu pintada de branco; FB -Telha de fibra vegetal e betume; FBP -Telha de fibra vegetal e betume pintada de branco, com 15 repetições, sendo as repetições os dias de medição. Dentre os horários estudados, o considerado menos confortável foi às 14h, sendo que a cobertura de fibra vegetal e betume foi a que apresentou maior valor de ITGU (84,1) quando comparada às demais coberturas, caracterizando uma situação de menor conforto térmico, não sendo observada diferença para CTR e H entre os tratamentos na região estudada.
Resumo:
Because of recent interest in bacteriophage therapy in poultry, information regarding the interaction of bacteriophages and potential host bacteria in the environment should be collected. The present studies were initiated with a rather typical commercial broiler integrator within the south-central United States to examine environmental Salmonella levels in two broiler complexes, attempt to isolate Salmonella-lytic bacteriophages, and elucidate a possible reason for differing apparent Salmonella prevalence. Significantly ( P<0.05) less Salmonella was isolated from houses in complex 1 ( 15/44 [ 34%] Salmonella-positive drag swabs) as compared to houses in complex 2 ( 22/24 [ 92%]). A total of seven Salmonella-lytic bacteriophages were isolated from Salmonella-positive environments, and two bacteriophages were isolated from a single Salmonella-negative house. During the initial bacteriophage isolation, individual bacteriophages did not replicate in the Salmonella host isolated from the same environment, and lysis of additional Salmonella hosts relied on high numbers of bacteriophage to be present. This suggests that the presence of these bacteriophages in the environment of a commercial broiler house had little to no effect on the presence of Salmonella. This study highlights the need to find additional bacteriophage sources, more effective isolation methods, and more innovative approaches to using bacteriophages to treat enteric disease.
Resumo:
Collections in households and industrial kitchens were done aiming at evaluating the potential of urban ants in spreading fungi. The most abundant ant species in households were Tapinoma melanocephalum and Paratrechina longicornis. In industrial kitchens Paratrechina longicornis and Monomorium floricola were the most common. Tapinoma melanocephalum was the species that most carried fungi, followed by Paratrechina longicornis, Tetramorium sp., Monomorium pharaonis and Monomorium floricola. An aflatoxigenic strain of Aspergillus flavus was isolated.
Resumo:
The energy efficiency of buildings should be a goal at the pre-design phase, though the importance of the design variables is often neglected even during the design process. Highlighting the relevance of these design variables, this research studies the relationships of building location variables with the electrical energy consumption of residential units. The following building design parameters are considered: orientation, story height and sky view factor (SVF). The consideration of the SVF as a location variable contributes to the originality of this research. Data of electrical energy consumption and users' profiles were collected and several variables were considered for the development of an Artificial Neural Network model. This model allows the determination of the relative importance of each variable. The results show that the apartments' orientation is the most important design variable for the energy consumption, although the story height and the sky view factor play a fundamental role in that consumption too. We pointed out that building heights above twenty-four meters do not optimize the energy efficiency of the apartments and also that an increasing SVF can influence the energy consumption of an apartment according to their orientation.
Resumo:
This study proposes the development of thermal and energy consumption maps to generate useful planning information. A residential neighbourhood in a medium-sized city was selected as the study area. In this area, 40 points were taken as urban reference points where air temperatures at the pedestrian level were collected. At the same time, rural temperatures made available by the city meteorological station were registered. Data of electrical energy consumption of the building units (houses and apartments) were collected through a household survey that was also designed to identify the users' income levels. Then, maps were developed so that the configuration of urban heat islands and electrical energy consumption could be visualised, compared and analysed. The results showed that the income level was the most important variable influencing electrical energy consumption. However, a strong relationship of the consumption with the thermal environment was also observed.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Geografia - IGCE
Resumo:
The human social organization has undergone major changes in recent years. The technological and digital revolutions accelerated the process of dissemination and evolution of the knowledge in all sciences, from social studies to nanotechnology. This process led to many advances that have enabled the emergence of new markets. Among these new markets, residential automation shows to be a market of great potential, seeking to meet the needs of residents, in order to make their daily practice and as fast as the rhythm of present life requests. To perform this task the residence stops being a passive place and becomes an active and controllable system, where actions may occur without the need for direct human interaction. The aim of this work is designing the electrical installation of a residence seeking better use of energy and show the technology diversity involving intelligent houses
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Many species of insects display a disposition to move towards light. As a consequence, nocturnal artificial lighting often contributes to an increase in insect population among humans. We tested the hypothesis that residential white lamps can evoke significantly different attraction to insects even when their light outputs are nearly indistinguishable to humans. In a two-choice experiment using insect traps equipped with either a compact fluorescent or a LED light source with similar photometric specifications, about three times more insects were captured in the trap with a compact fluorescent lamp than in the LED trap. The results suggest that LED lamps are preferable to compact fluorescent lamps when the objective is to avoid attracting nocturnal insects to households.