14 resultados para requirement specification

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The software industry has become more and more concerned with the appropriate application of activities that composes requirement engineering as a way to improve the quality of its products. In order to support these activities, several computational tools have been available in the market, although it is still possible to find a lack of resources related to some activities. In this context, this paper proposes the inclusion of a module to aid in the requirements specification to a tool called Requirements Elicitation Support Tool. This module allows to specify requirements in accordance with IEEE 830 standard, thus contributing to the documentation of the requirements established for a software system, besides supporting the learning of concepts related to the requirements specification, which improves the skills of users of the tool. © 2012 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Gesture-based applications have particularities, since users interact in a natural way, much as they interact in the non-digital world. Hence, new requirements are needed on the software design process. This paper shows a software development process model for these applications, including requirement specification, design, implementation, and testing procedures. The steps and activities of the proposed model were tested through a game case study, which is a puzzle game. The puzzle is completed when all pieces of a painting are correctly positioned by the drag and drop action of users hand gesture. It also shows the results obtained of applying a heuristic evaluation on this game. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The advantages offered by the electronic component light emitting diode ( LED) have caused a quick and wide application of this device in replacement of incandescent lights. However, in its combined application, the relationship between the design variables and the desired effect or result is very complex and it becomes difficult to model by conventional techniques. This work consists of the development of a technique, through artificial neural networks, to make possible to obtain the luminous intensity values of brake lights using LEDs from design data. (C) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To compare the effect of intraperitoneal (IP) or incisional (INC) bupivacaine on pain and the analgesic requirement after ovariohysterectomy in dogs.Study design Prospective, randomized clinical study.Animals Thirty female dogs undergoing ovariohysterectomy (OHE).Methods Dogs admitted for elective OHE were anesthetized with acepromazine, butorphanol, thiopental and halothane. Animals were randomly assigned to one of three groups (n = 10 per group). The treatments consisted of preincisional infiltration with saline solution (NaCl 0.9%) or bupivacaine with epinephrine and/or IP administration of the same solutions, as follows: INC and IP 0.9% NaCl (control group); INC 0.9% NaCl and IP bupivacaine (5 mg kg(-1), IP group); INC bupivacaine (1 mg kg(-1)) and IP 0.9% NaCl (INC group). Postoperative pain was evaluated by a blinded observer for 24 hours after extubation by means of a visual analog scale (VAS) and a numeric rating scale (NRS). Rescue analgesia (morphine, 0.5 mg kg(-1), IM) was administered if the VAS was > 5/10 or the NRS > 10/29.Results At 1 hour after anesthesia, VAS pain scores were [medians (interquartile range)]: 6.4 (3.1-7.9), 0.3 (0.0-2.6) and 0.0 (0.0-7.0) in control, IP and INC groups, respectively. VAS pain scores were lower in the IP compared to the control group. Over the first 24 hours, rescue analgesia was administered to 7/10, 5/10 and 3/10 dogs of the control, INC and IP groups, respectively. Total number of dogs given rescue analgesia over the first 24 hours did not differ significantly among groups.Conclusions and clinical relevance Intraperitoneal bupivacaine resulted in lower pain scores during the first hour of the postoperative period and there was a trend towards a decreased need for rescue analgesia after OHE in dogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Because water sorption of autopolymerizing acrylic reline resins is accompanied by volumetric change, it is a physical property of importance. As residual monomer leaches into the oral fluids and causes tissue irritation, low solubility of these resins is desired. Another requirement is a satisfactory bond between the autopolymerizing acrylic resins and the denture base acrylic resin. PURPOSE: This study compared the water sorption, solubility, and the transverse bond strength of 2 autopolymerizing acrylic resins (Duraliner II and Kooliner) and 1 heat-polymerizing acrylic resin (Lucitone 550). MATERIAL AND METHODS: The water sorption and solubility test was performed as per International Standards Organization Specification No. 1567 for denture base polymers. Bond strengths between the autopolymerizing acrylic resins and the heat-polymerizing acrylic resin were determine with a 3-point loading test made on specimens immersed in distilled water at 37 degrees C for 50 hours and for 30 days. Visual inspection determined whether failures were adhesive or cohesive. RESULTS: Duraliner II acrylic resin showed significantly lower water sorption than Kooliner and Lucitone 550 acrylic resins. No difference was noted in the solubility of all materials. Kooliner acrylic resin demonstrated significantly lower transverse bond strength to denture base acrylic resin and failed adhesively. The failures seen with Duraliner II acrylic resin were primarily cohesive in nature. CONCLUSIONS: Autopolymerizing acrylic reline resins met water sorption and solubility requirements. However, Kooliner acrylic resin demonstrated significantly lower bond strength to denture base acrylic resin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ten isonitrogenous casein-gelatin-based diets were formulated to contain five estimated metabolizable energy concentrations (10.92, 12.29, 13.63, 14.82 and 16.16 kJ g -1) at two carbohydrate-to-lipid ratios (CHO : L, 5.3 and 12.8, g : g) in a 5 × 2 factorial arrangement. Each diet was assigned to triplicate groups of 11 piracanjuba fingerlings (5.25 ± 0.14 g) and fed to apparent satiation twice a day for 90 days. Higher daily weight gain was obtained by fish fed the 13.63 kJ g -1 diets for both CHO : L ratios. There was a significant reduction of feed consumption when dietary energy concentration increased above 13.63 kJ g -1. Feed conversion ratio and apparent net energy retention improved as dietary energy increased. Apparent net protein retention tended to be lower in the highest and lowest dietary energy concentrations. The results suggest that dietary lipid energy was more efficiently utilized by piracanjuba fingerlings than carbohydrate energy. Body composition and hepatosomatic index (HSI) were not influenced by dietary CHO : L ratio. However, an increase in dietary energy concentration beyond 13.63 kJ g -1 resulted in a significant increment in lipid deposition, while body moisture and HSI decreased. Our findings indicate that at 300 g kg -1 dietary crude protein, a CHO : L ratio of 5.3 is recommended for piracanjuba, and the required energy is either 13.63 kJ g -1 if raised for aquaculture or 14.82 kJ g -1 if destined to stock enhancement. © 2006 Blackwell Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Juvenile Nile tilapia, Oreochromis niloticus, were fed to apparent satiation twice daily with purified diets containing 0, 1.0, 2.0, 4.0, 8.0, and 16.0 mg/kg and 0, 2.0, 4.0, 8.0, 16.0, and 32.0 mg/kg of thiamin in separate 14- and 8-wk trials (Experiments 1 and 2, respectively). Fish fed the diet devoid of thiamin developed neurological disorders, anorexia, reduced growth, and feed efficiency and increased mortality (Experiment 2 only) within 4-6 and 8-10 wk for Experiments 2 and 1, respectively. Low red blood cell count (RBC) and hematocrit (Ht) were observed in fish fed the thiamin-deficient diet. Serum pyruvate was elevated in fish fed the thiamin unsupplemented diet. Serum lactate was not affected by dietary thiamin levels. Whole body protein was unaffected by dietary levels of thiamin. Body moisture and ash increased whereas body lipid decreased in fish fed the thiamin unsupplemented diets. None of these abnormalities were observed in fish fed the thiamin-supplemented diets. Using the response curves determined by PROC NLMIXED to estimate dietary thiamin levels required for various response variables, a dietary thiamin level of 3.5 mg/kg diet was adequate for optimum growth, feed intake and efficiency, survival, prevention of neurological symptoms, and maintaining normal levels of RBC, Ht, serum pyruvate, and proximate body composition. © 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a growing search for continuous improvement within the companies which creates an obligation of reducing and when it is possible eliminating waste. Production Planning and Control Department (PCP) is not out of this question, making necessary the application of methods and creation of tools that eliminate steps which do not add value to the planning process. This paper aims to develop a tool which concentrates in just one place all the necessary information to make the packaging material requirement planning (MRP) in a agribusiness company. Besides, it also aims, in a more visual way and using devices that prevent mistakes (Poka-Yoke), to reduce the number of reviews and mistakes made by analysts. As a result, an Excel spreadsheet was developed. This spreadsheet shows what happens with the status of planning and receiving of packaging, giving some advices when some critical situation happens. The use of Lean Manufacturing Method and the action research method helped to well define the problem and to reduce the number of steps, spreadsheets and time of process in 80%, 60% and 75%, respectively