232 resultados para pulmonary artery

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to evaluate the effect of physical preconditioning in the responsiveness of rat pulmonary rings submitted to lung ischemia/reperfusion (IR). Wistar rats were divided into three groups: Sedentary sham-operated (SD/SHAM); sedentary submitted to ischemia/reperfusion (SD/IR) and trained submitted to ischemia/reperfusion (TR/IR) animals. Exercise training consisted in sessions of 60 min/day running sessions, 5 days/week for 8 weeks. Left pulmonary IR was performed by occluding for 90 min and reperfusing for 120 min. After that, pulmonary arteries were isolated and concentration-response curves to acetylcholine (ACh), histamine (HIST), sodium nitroprusside (SNP), phenylephrine and U46619 were obtained. Neither potency (- log EC50) nor maximal responses (Emax) were modified for ACh and HIST in all groups. On the other hand, the potency for SNP was significantly increased in TR/IR group (8.23 ± 0.06) compared to SD/IR group (7.85 ± 0.04). Contractile responses mediated by a-adrenergic receptor were markedly decreased in IR groups (SD/IR: 6.75 ± 0.06 and TR/IR: 6.62 ± 0.04) compared to SD/SHAM (7.33 ± 0.05). No changes were seen for the U46619 in all groups. In conclusion, the present study shows that exercise training has no protective actions in the local blood vessel where the IR process takes place. © 2006 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In spontaneously breathing cardiac patients, pulmonary artery pressure (PAP) can be accurately estimated from the transthoracic Doppler study of pulmonary artery and tricuspid regurgitation blood flows. In critically ill patients on mechanical ventilation for acute lung injury, the interposition of gas between the probe and the heart renders the transthoracic approach problematic. This study was aimed at determining whether the transesophageal approach could offer an alternative. METHODS: Fifty-one consecutive sedated and ventilated patients with severe hypoxemia (arterial oxygen tension/fraction of inspired oxygen < 300) were prospectively studied. Mean PAP measured from the pulmonary artery catheter was compared with several indices characterizing pulmonary artery blood flow assessed using transesophageal echocardiography: preejection time, acceleration time, ejection duration, preejection time on ejection duration ratio, and acceleration time on ejection duration ratio. In a subgroup of 20 patients, systolic PAP measured from the pulmonary artery catheter immediately before withdrawal was compared with Doppler study of regurgitation tricuspid flow performed immediately after pulmonary artery catheter withdrawal using either the transthoracic or the transesophageal approach. RESULTS: Weak and clinically irrelevant correlations were found between mean PAP and indices of pulmonary artery flow. A statistically significant and clinically relevant correlation was found between systolic PAP and regurgitation tricuspid flow. In 3 patients (14%), pulmonary artery pressure could not be assessed echocardiographically. CONCLUSIONS: In hypoxemic patients on mechanical ventilation, mean PAP cannot be reliably estimated from indices characterizing pulmonary artery blood flow. Systolic PAP can be estimated from regurgitation tricuspid flow using either transthoracic or transesophageal approach. © 2008 American Society of Anesthesiologists, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulmonary artery sarcomas (PAS) are rare and probably incurable tumours. The clinical manifestations are non-specific and very similar to that of patients with thromboembolic disease, resulting in delay of the correct diagnosis and proper treatment. We report the case of a 66-year-old woman with PAS diagnosed by computed tomography guided biopsy. Chemotherapy treatment was initiated but the patient died 11 months after diagnosis.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Sildenafil attenuates acute pulmonary embolism-induced pulmonary hypertension. However, the hemodynamic effects of sildenafil in combination with other vasodilators during acute pulmonary embolism have not been examined yet. In the present study, we examined the hemodynamic effects of combined sildenafil (0.25 mg/kg, i.v.) and L-arginine (100, 200, 500, and 1000 mg/kg/h, i.v.) in an anesthetized dog model of acute pulmonary embolism. Plasma nitrite/nitrate (NOx) and cGMP concentrations were determined using an ozone-based chemiluminescence assay and a commercial enzyme immunoassay, respectively. We found that L-arginine alone did not attenuate acute pulmonary embolism-induced pulmonary hypertension. However, significant decreases in mean pulmonary artery pressure were observed 30, 45, 60, and 75 min after the administration of sildenafil alone or after the combined administration of sildenafil and L-arginine (all P<0.05). No significant differences among groups were observed in the respiratory parameters. While L-arginine significantly increased NOx concentrations, cGMP concentrations increased only when sildenafil was administered (all P<0.05). These results suggest that while sildenafil attenuates acute pulmonary embolism-induced pulmonary hypertension, L-arginine does not enhance the beneficial hemodynamic effects of sildenafil. In addition, these findings suggest that stimulation of NO synthesis with L-arginine during acute pulmonary embolism does not produce beneficial effects. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ObjectiveTo compare cardiac output (CO) measured by Doppler echocardiography and thermodilution techniques in spontaneously breathing dogs during continuous infusion of propofol. To do so, CO was obtained using the thermodilution method (CO(TD)) and Doppler evaluation of pulmonary flow (CO(DP)) and aortic flow (CO(DA)).Study designProspective cohort study.AnimalsEight adult dogs weighing 8.3 +/- 2.0 kg.MethodsPropofol was used for induction (7.5 +/- 1.9 mg kg-1 IV) followed by a continuous rate infusion at 0.7 mg kg-1 minute-1. The animals were positioned in left lateral recumbency on an echocardiography table that allowed for positioning of the transducer at the 3rd and 5th intercostal spaces of the left hemithorax for Doppler evaluation of pulmonary and aortic valves, respectively. CO(DP) and CO(DA) were calculated from pulmonary and aortic velocity spectra, respectively. A pulmonary artery catheter was inserted via the jugular vein and positioned inside the lumen of the pulmonary artery in order to evaluate CO(TD). The first measurement of CO(TD), CO(DP) and CO(DA) was performed 30 minutes after beginning continuous infusion (T0) and then at 15-minute intervals (T15, T30, T45 and T60). Numeric data were submitted to two-way anova for repeated measurements, Pearson's correlation coefficient and Bland & Altman analysis. Data are presented as mean +/- SD.ResultsAt T0, CO(TD) was lower than CO(DA). CO(DA) was higher than CO(TD) and CO(DP) at T30, T45 and T60. The difference between the CO(TD) and CO(DP), when all data were included, was -0.04 +/- 0.22 L minute-1 and Pearson's correlation coefficient (r) was 0.86. The difference between the CO(TD) and CO(DA) was -0.87 +/- 0.54 L minute-1 and r = 0.69. For CO(TD) and CO(DP), the difference was -0.82 +/- 0.59 L minute-1 and r = 0.61.ConclusionDoppler evaluation of pulmonary flow was a clinically acceptable method for assessing the CO in propofol-anesthetized dogs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: O pinçamento infra-renal da aorta abdominal pode produzir alterações hemodinâmicas. O objetivo do estudo foi avaliar os efeitos do halotano, isoflurano e sevoflurano sobre a função cardiovascular, em cães submetidos à pinçamento aórtico infra-renal. MÉTODO: O estudo aleatório foi realizado em 30 cães, distribuídos em três grupos, de acordo com o anestésico halogenado utilizado durante a anestesia, em concentrações equipotentes de 0,75 CAM: GH (n=10) - halotano a 0,67%; GI (n=10) - isoflurano a 0,96%; e GS (n=10) - sevoflurano a 1,8%. em todos os animais foi realizada ligadura infra-renal da aorta, por período de 30 min. Os atributos hemodinâmicos foram estudados nos momentos: C (Controle), Ao15 e Ao30, respectivamente após 15 e 30 minutos do pinçamento aórtico, e DAo e DAo15, respectivamente, imediatamente e após 15 min do despinçamento aórtico. RESULTADOS: Durante o pinçamento aórtico houve, em todos os grupos, aumento das pressões arterial média e do átrio direito, e dos índices cardíaco, sistólico e de trabalho sistólico dos ventrículos direito e esquerdo. A pressão da artéria pulmonar aumentou em GI e GS e a pressão pulmonar ocluída em GH e GI. Após o despinçamento aórtico, houve normalização dos atributos que haviam se elevado, com exceção dos índices cardíaco e sistólico, que continuaram elevados, acompanhados de diminuição do índice de resistência vascular sistêmica. Não houve diferença significante entre os grupos em relação aos atributos estudados, com exceção da freqüência cardíaca que foi sempre menor em GH, em relação aos demais grupos, durante o pinçamento e despinçamento aórtico. CONCLUSÕES: No cão, nas condições experimentais empregadas, a inalação do halotano, isoflurano e sevoflurano em concentrações equipotentes (0,75 CAM) não atenua as respostas cardiovasculares ao pinçamento aórtico infra-renal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: O pinçamento aórtico infra-renal pode determinar alterações cardiovasculares. A clonidina, um alfa2-agonista, determina bradicardia e diminuição da pressão arterial. O objetivo do estudo foi avaliar os efeitos da clonidina sobre a função cardiovascular, em cães submetidos a pinçamento aórtico infra-renal. MÉTODO: O estudo aleatório foi realizado em 16 cães, distribuídos em dois grupos: G Controle - sem a utilização de clonidina e G Clon - clonidina, na dose inicial de 5 µg.kg-1, por via venosa, imediatamente antes do pinçamento aórtico infra-renal, seguido de 2 µg.min-1.m² até o final do estudo. em todos os animais foi realizada ligadura infra-renal da aorta, por 45 minutos. Os atributos hemodinâmicos foram estudados nos momentos C (controle), após 10 (Ao10) e 25 (Ao25) minutos do pinçamento aórtico, e após 10 (DAo10) e 25 (DAo25) minutos do despinçamento aórtico. RESULTADOS: Durante o pinçamento aórtico, houve diferença significante entre os grupos, em relação à freqüência cardíaca, pressão arterial média e índice cardíaco (G Controle > G Clon). Após o despinçamento aórtico houve diferença significante entre os grupos, em relação à freqüência cardíaca (G Controle > G Clon) e pressões do átrio direito e da artéria pulmonar ocluída (G Clon > G Controle). Durante o pinçamento aórtico, houve nos dois grupos, aumento significante das pressões de átrio direito e artéria pulmonar ocluída, dos índices sistólico e do trabalho sistólico do ventrículo esquerdo, e diminuição do índice de resistência vascular pulmonar. No grupo controle houve aumento significante das pressões arterial média e da artéria pulmonar, e dos índices cardíaco e do trabalho sistólico do ventrículo direito. No grupo clonidina, houve diminuição significante da freqüência cardíaca. Após o despinçamento aórtico, houve nos dois grupos: diminuição significante da freqüência cardíaca e pressão arterial média, enquanto os valores das pressões do átrio direito e índice sistólico continuaram elevados. No grupo controle, os valores do índice de trabalho sistólico do ventrículo direito continuaram elevados enquanto os valores do índice cardíaco retornaram a valores próximos aos do controle. No grupo clonidina, os valores das pressões do átrio direito e da artéria pulmonar ocluída, e o índice sistólico, continuaram significantemente elevados. CONCLUSÕES: No cão, nas condições experimentais empregadas, a administração venosa contínua de clonidina atenua as respostas cardiovasculares decorrentes do pinçamento aórtico infra-renal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Some properties of the volatile anesthetics, such as vasodilatation and myocardial depression, combined with the sympathetic inhibition that alpha 2-agonists can produce may determine hemodynamic alterations during aortic, surgery. The interaction between dexmedetomidine (DEX), an alpha 2-agonist, and sevoflurane during aortic surgery is unknown. We studied the effects of DEX on hemodynamics and systemic oxygenation during aortic cross-clamping (Aox) and unclamping (UAox) in sevoflurane-anesthetized dogs Twenty dogs were. anesthetized with sevoflurane and were randomly assigned to two groups prior to Aox and UAox: control, n = 10, received saline infusion only, and DEX (1 mu g.kg(-1) load followed by 1 mu g.kg(-1).h(-1) infusion), n = 10. Hemodynamic and oxygenation variables were measured at baseline, after saline or DEX loading dose, 20 and 40 min after Aox, and 20 and 40 min after UAox. After DEX administration, heart rate, cardiac index l and systemic oxygen transport index (131021) were lower than in control group. Aox increased mean arterial pressure (MAP) and systemic vascular resistance index (SVRI) in both groups, but the effects were greater with DEX. Cl, heart rate, and DO(2)I were lower, while central venous pressure (CVP) and pulmonary artery occlusion pressure were higher in DEX compared to control. After UAox, MAP, CVP and SVRI were maintained higher in DEX in relation to control. We conclude that in sevoflurane-anesthetized dogs DEX alters the cardiovascular response during aortic surgery.