58 resultados para plastic instability

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new analytical theory including friction was developed to assess strain limits in punch stretching of anisotropic sheet metals. This new approach takes into consideration the anisotropic behaviour of sheet materials and could explain the mechanical behaviour of a variety of anisotropic sheet materials. The theory explains the sheet metal failure so for the drawing as the stretching region of the forming limit curve, particularly for materials that present the strain-ratio dependence of limit strain ε 1, where dε 1/dρ is not always greater than zero. dε 1/ dρ or dε 1/dε 2 could be equal to or smaller than zero for a range of materials. Therefore, this new theory can explains such experimental observations, besides to assuming that membrane element relations near the pole, for the case of punch stretching are dependent of sheet metal properties as the process history and also suggests that the onset of local necking is controlled by shear. Thus, theoretical results obtained through this new approach are compared with experimental results available in the literature. It is demonstrated the effect of friction on a FLC curve for both regions, drawing and stretching. © 2010 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Propose a new experimental model of bladder instability in rabbits after partial bladder obstruction. MATERIALS and METHODS: Thirty North Folk male rabbits, weighting 1,700 to 2,820 g (mean: 2,162 g) were studied. The animals were distributed in 2 experimental groups, formed by 15 rabbits each: Group 1 - clinical control. In this group there was no surgical intervention; Group 2 - bladder outlet obstruction. In this group, after anesthetizing the animal, urethral cannulation with Foley catheter 10F was performed and then an adjustable plastic bracelet was passed around the bladder neck. It was then adjusted in order to not constrict the urethra. The following parameters were studied in M1 - pre-operative period; M2 - 4 weeks post-operatively moments: 1)- urine culture; 2)- cystometric study; 3)- serum creatinine and BUN. RESULTS: Bladder weight was 2.5 times larger in the group with obstruction than in the control group. Cystometric evaluation showed a significant increase in maximal vesical volume in the final moment at Group G2. However, there was no statistically significant difference among the groups studied. There was no statistically significant difference between maximal detrusor pressure and vesical compliance in the different moments or in the studied groups. There was an absence of uninhibited detrusor contractions in all the animals in group 1, and involuntary contractions were detected in 93% of group 2 animals. There was no significant variation in BUN and serum creatinine either among the groups or in the same group. CONCLUSIONS: We observed in the group with obstruction a bladder weight 2.5 higher than normal bladders. We detected involuntary contractions in 93% of the animals in group 2, establishing this experimental model as appropriate to secondary bladder instability and partial bladder outlet obstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temporally-growing frontal meandering and occasional eddy-shedding is observed in the Brazil Current (BC) as it flows adjacent to the Brazilian Coast. No study of the dynamics of this phenomenon has been conducted to date in the region between 22 degrees S and 25 degrees S. Within this latitude range, the flow over the intermediate continental slope is marked by a current inversion at a depth that is associated with the Intermediate Western Boundary Current (IWBC). A time series analysis of 10-current-meter mooring data was used to describe a mean vertical profile for the BC-IWBC jet and a typical meander vertical structure. The latter was obtained by an empirical orthogonal function (EOF) analysis that showed a single mode explaining 82% of the total variance. This mode structure decayed sharply with depth, revealing that the meandering is much more vigorous within the BC domain than it is in the IWBC region. As the spectral analysis of the mode amplitude time series revealed no significant periods, we searched for dominant wavelengths. This search was done via a spatial EOF analysis on 51 thermal front patterns derived from digitized AVHRR images. Four modes were statistically significant at the 95% confidence level. Modes 3 and 4, which together explained 18% of the total variance, are associated with 266 and 338-km vorticity waves, respectively. With this new information derived from the data, the [Johns, W.E., 1988. One-dimensional baroclinically unstable waves on the Gulf Stream potential vorticity gradient near Cape Hatteras. Dyn. Atmos. Oceans 11, 323-350] one-dimensional quasi-geostrophic model was applied to the interpolated mean BC-IWBC jet. The results indicated that the BC system is indeed baroclinically unstable and that the wavelengths depicted in the thermal front analysis are associated with the most unstable waves produced by the model. Growth rates were about 0.06 (0.05) days(-1) for the 266-km (338-km) wave. Moreover, phase speeds for these waves were low compared to the surface BC velocity and may account for remarks in the literature about growing standing or stationary meanders off southeast Brazil. The theoretical vertical structure modes associated with these waves resembled very closely to the one obtained for the current-meter mooring EOF analysis. We interpret this agreement as a confirmation that baroclinic instability is an important mechanism in meander growth in the BC system. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo examinou as respostas de estresse de juvenis de pirarucu transportados em sistema fechado. Pirarucu (Arapaima gigas) é um peixe nativo da bacia Amazônica, da família Osteoglossidae que possui respiração aérea obrigatória. Foi realizado um transporte de curta duração (6 h) em sacos de polietileno inflados com ar atmosférico (grupo ar) ou com oxigênio puro (grupo oxi). O oxigênio dissolvido foi o único parâmetro de qualidade da água que apresentou diferença estatística entre os grupos, e como esperado, o oxigênio estava supersaturado para o grupo oxi. Não houve mortalidade após o transporte em ambos os grupos. Os peixes se alimentaram 36 h após o transporte e apresentaram um consumo de ração habitual após 72 h. As respostas fisiológicas foram semelhantes nos dois grupos. O cortisol não apresentou mudança significativa durante o período de amostragem. Ao contrário da maioria das espécies, os valores de cortisol se apresentaram inalterados nos dois grupos durante a amostragem, enquanto a glicose teve um aumento significativo até 12 h após o transporte. Os resultados mostram que o transporte de pirarucu em sacos de polietileno pode ser realizado com ar atmosférico ou oxigênio puro, uma vez que as respostas de estresse, a qualidade da água e o comportamento alimentar após 36 h foram similar entre os grupos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an experimental investigation of the characteristics of leak noise in plastic water-filled pipes. An experimental set-up was designed to identify the physical mechanisms of leak noise generation. Possible mechanisms include cavitation and turbulence. The experiments show that cavitation is not responsible for leak noise generation and clearly indicate that turbulence is the main mechanism, at least in the experiments conducted. An alternative experimental set-up was also designed to identify the characteristics of leak noise spectra and to investigate how the spectra are affected by the leak size and the leak flow velocity. A number of different hole sizes (leaks) starting from 1 mm diameter, increasing progressively every 0.5 mm until a size of 4 mm diameter were tested for different jet velocities and an empirical model that describes this behaviour is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A interação entre arte e ciência foi intensa durante o Renascimento, sofrendo declínio nos anos posteriores com retomada significativa no século XX, principalmente com o uso de técnicas de identificação, datação de obras de arte e o desenvolvimento de novos materiais. O relacionamento entre artes plásticas e Cirurgia da Mão mantêm-se intenso , sendo freqüente o uso de reproduções artísticas da mão nas ilustrações de textos científicos. Objetivando compreender o papel da mão nas artes plásticas, reproduções de obras de artes (esculturas e pinturas) representativas de vários estilos ou períodos da história da arte foram analisadas com enfoque no estudo das mãos. Detalhes anatômicos, relacionamento com outras estruturas do corpo humano, papel na composição e aspectos simbólicos das mãos foram estudados no contexto histórico e artístico de obras de arte do período paleolítico (pré-história) até o século XX. A representação da mão nas artes plásticas está diretamente relacionada ao estilo ou período da obra e à capacidade individual de interpretação e execução do artista.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

4-Nitroquinotine 1-oxide (4NQO)-induced rat tongue carcinogenesis is a useful model for studying oral squamous cell carcinoma. The aim of this study was to investigate the level of DNA damage induced by 4NQO in oral mucosa cells by the single cell get (comet) assay. Mate Wistar rats were distributed into three groups of 10 animals each and treated with 50 ppm 4NQO solution by drinking water for 4, 12 or 20 weeks. Ten animals were used as negative control. Statistically significant increase of DNA damage was observed in non-neoplastic oral cells at four weeks of 4NQO administration when compared with control (P < 0.05). The level of DNA damage was directly associated with the severity of histological changes. The results suggest that histologically normal tissue is able to harbor genetically unstable cells contributing to the initiation of oral carcinogenesis. Genomic instability appears to be associated with the risk and progression of oral cancer. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present article describes the preparation and characterization A anionic Collagen gels obtained from porcine intestinal submucosa after 72 h of alkaline treatment and in the form of rhamsan composites to develop injectable biomaterials for plastic for construction. All materials were characterized by SDS/polyacrylamide gel electrophoresis, infrared spectroscopy, thermal stability, potentiometric titration, rheological properties, and fluidity tests. Biocompatibility was appraised after the injection of anionic collagen:rhamsan composites at 2.5% in 60 North Folk rabbits. Independently of processing, the Collagen's secondary structure was preserved in all cases, and after 72 h of hydrolysis the Collagen was characterized by a carboxyl group content of 346 :L 9, which, at physiological pH, corresponds to an increase of 106 17 negative charges, in comparison to native Collagen, due to the selective hydrolysis of asparagine and glutamine carboxyamide side chain. Rheological studies of composites at pH 7.4 in concentrations of 2, 4, and 6% (in proportions of 75:1 and 50:1) showed a viscoelastic behavior dependent on the frequency, which is independent of concentration and proportion. In both, the concentration of the storage modulus always predominated over the loss modulus (G' > G and delta < 45 degrees). The results from creep experiments confirmed this behavior and showed that anionic collagen:rhamsan composites at pH 7.4 in the proportion of 50:1 are less elastic and more susceptible to deformation in comparison to gels in the proportion of 75:1, independent of concentration. This was further confirmed by flow experiments, indicating that the necessary force for the extrusion of anionic collagen:rhamsan composites, in comparison to anionic Collagen, was significantly smaller and with a smooth flow. Biocompatibility studies showed that the tissue reaction of anionic collagen:rhamsan composites at 2.5% in the proportion of 75:1 was compatible with the application of these gels in plastic reconstruction. These results suggest that the association of Collagen with rhamsan may be a good alternative in the replacement of glutaraidehyde to stabilize the microfibril assembly of commercial Collagen gel preparations. (c) 2005 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This in vitro study evaluated the dimensional accuracy of two impression techniques (tapered and splinted) with two stock trays (plastic and metal) for implant-supported prostheses. Materials and Methods: A master cast with four parallel abutment analogs and a passive framework were fabricated. Polyvinyl siloxane impression material was used for all impressions with two metal stock trays and two plastic stock trays (closed and open trays). Four groups (tapered plastic, splinted plastic, tapered metal, and splinted metal) and a control group (master cast) were tested (n = 5 for each group). After the framework was seated on each of the casts, one abutment screw was tightened, and the marginal gap between the abutment and framework on the other side was measured with a stereomicroscope. The measurements were analyzed with the Kruskal-Wallis one-way analysis of variance on ranks test followed by the Dunn method. Results: The mean values (+/- standard deviations) for the abutment/framework interface gaps were: master cast, 32 +/- 2 mu m; tapered metal, 44 +/- 10 mu m; splinted metal, 69 +/- 28 mu m; tapered plastic, 164 +/- 58 mu m; splinted plastic, 128 +/- 47 mu m. No significant difference was detected between the master cast, tapered metal, and splinted metal groups or between the tapered and splinted plastic groups. Conclusions: In this study, the rigidity of the metal stock tray ensured better results than the plastic stock tray for implant impressions with a high-viscosity impression material (putty). Statistically similar results were obtained using tapered impression copings and splinted squared impression copings. The tapered impression copings technique and splinted squared impression copings technique with a metal stock tray produced precise casts with no statistically significant difference in interface gaps compared to the master cast. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:544-550.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)