23 resultados para performance monitoring

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Biociências e Biotecnologia Aplicadas à Farmácia - FCFAR

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study was undertaken to characterize the effects of monotonous training at lactate minimum (LM) intensity on aerobic and anaerobic performances; glycogen concentrationsin the soleus muscle, the gastrocnemius muscle and the liver; and creatine kinase (CK), free fatty acids and glucose concentrations in rats. The rats were separated into trained (n =10), baseline (n = 10) and sedentary (n=10) groups. The trained group was submitted to the following: 60 min/day, 6 day/week and intensity equivalent to LM during the 12-week training period. The training volume was reduced after four weeks according to a sigmoid function. The total CK (U/L) increased in the trained group after 12 weeks (742.0±158.5) in comparison with the baseline (319.6±40.2) and the sedentary (261.6+42.2) groups. Free fatty acids and glycogen stores (liver, soleus muscle and gastrocnemius muscle) increased after 12 weeks of monotonous training but aerobic and anaerobic performances were unchanged in relation to the sedentary group. The monotonous training at LM increased the level of energy substrates, unchanged aerobic performance, reduced anaerobic capacity and increased the serum CK concentration; however, the rats did not achieve the predicted training volume.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo do presente estudo foi verificar a utilização da velocidade de 30 minutos (VT-30), freqüência de braçada (fB), comprimento de braçada (CB) e índice de braçada (IB), obtidos no teste T-30, como métodos não-invasivos para determinação da performance aeróbia e técnica de nadadores treinados. Catorze nadadores submeteram-se a três esforços de 400m (85, 90 e 100% do esforço máximo) para determinação da velocidade de limiar anaeróbio (VLan) correspondente à concentração fixa de 3,5mM de lactato e um esforço máximo de 30 minutos (VT-30). fB, CB e IB foram calculados nos 10m centrais da piscina (nado limpo) para o teste T-30 (fBT-30, CBT-30 e IBT-30) e progressivo. Através da relação entre VLan e parâmetros de braçada no teste progressivo, determinaram-se freqüência de braçada de limiar (fBLan), comprimento de braçada de limiar (CBLan) e índice de braçada de limiar (IBLan). O tempo para realizar 400m em máximo esforço foi considerado como parâmetro de performance (P400). Não foi encontrada diferença significativa entre VLan (1,29 ± 0,07m.s-1) e VT-30 (1,29 ± 0,08m.s-1), que ainda apresentaram alta correlação (r = 0,90). Os valores de fBLan (33,6 ± 4,14 ciclos/min) e fBT-30 (34,9 ± 3,53 ciclos/min) e de CBLan (2,09 ± 0,20m/ciclo) e CBT-30 (2,09 ± 0,20m/ciclo) também não foram significativamente diferentes. Correlações significativas (p < 0,05) também foram encontradas entre VT-30 e P400 (r = 0,95); fBLan e fBT-30 (r = 0,73); CBLan e CBT-30 (r = 0,89) e IBLan e IBT-30 (r = 0,94). Conclui-se que a VT30 se mostrou confiável para o monitoramento do treinamento, predição da performance e determinação de parâmetros relacionados à técnica de nadadores.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este artigo considera um gráfico np x proposto por Wu et al. (2009) para controle de média de processo como uma alternativa ao uso do gráfico de. O que distingue do gráfico de controle np x é o fato das unidades amostrais serem classificadas como unidades de primeiro ou de segunda classe de acordo com seus limites discriminantes. O gráfico tradicional np é um caso particular do gráfico np x quando os limites discriminantes coincidem com os limites de especificação e unidade de primeira (segunda) classe é um item conforme (não conforme). Estendendo o trabalho de Reynolds Junior, Arnold e Baik (1996), consideramos que a média de processo oscila mesmo na ausência de alguma causa especial. As propriedades de Cadeia de Markov foram adotadas para avaliar o desempenho do gráfico np x no monitoramento de média de processos que oscila. de modo geral, o gráfico np x requer amostras duas vezes maior para superar desempenho do gráfico (enquanto que o gráfico tradicional np necessita tamanho de amostras cinco ou seis vezes maior).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article, we consider the synthetic control chart with two-stage sampling (SyTS chart) to control the process mean and variance. During the first stage, one item of the sample is inspected; if its value X, is close to the target value of the process mean, then the sampling is interrupted. Otherwise, the sampling goes on to the second stage, where the remaining items are inspected and the statistic T = Sigma [x(i) - mu(0) + xi sigma(0)](2) is computed taking into account all items of the sample. The design parameter is function of X-1. When the statistic T is larger than a specified value, the sample is classified as nonconforming. According to the synthetic procedure, the signal is based on Conforming Run Length (CRL). The CRL is the number of samples taken from the process since the previous nonconforming sample until the occurrence of the next nonconforming sample. If the CRL is sufficiently small, then a signal is generated. A comparative study shows that the SyTS chart and the joint X and S charts with double sampling are very similar in performance. However, from the practical viewpoint, the SyTS chart is more convenient to administer than the joint charts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a non-model based technique to detect, locate, and characterize structural damage by combining the impedance-based structural health monitoring technique with an artificial neural network. The impedance-based structural health monitoring technique, which utilizes the electromechanical coupling property of piezoelectric materials, has shown engineering feasibility in a variety of practical field applications. Relying on high frequency structural excitations (typically >30 kHz), this technique is very sensitive to minor structural changes in the near field of the piezoelectric sensors. In order to quantitatively assess the state of structures, multiple sets of artificial neural networks, which utilize measured electrical impedance signals for input patterns, were developed. By employing high frequency ranges and by incorporating neural network features, this technique is able to detect the damage in its early stage and to estimate the nature of damage without prior knowledge of the model of structures. The paper concludes with experimental examples, investigations on a massive quarter scale model of a steel bridge section and a space truss structure, in order to verify the performance of this proposed methodology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The MRMAX chart is a single chart based on the standardized sample means and sample ranges for monitoring the mean vector and the covariance matrix of multivariate processes. User's familiarity with the computation of these statistics is a point in favor of the MRMAX chart. As a single chart, the recently proposed MRMAX chart is very appropriate for supplementary runs rules. In this article, we compare the supplemented MRMAX chart and the synthetic MRMAX chart with the standard MRMAX chart. The supplementary and the synthetic runs rules enhance the performance of the MRMAX chart. © 2013 Elsevier Ltd.