155 resultados para number and operation

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bone is a mineralized tissue that is under the influence of several systemic, local and environmental factors. Among systemic factors, estrogen is a hormone well known for its inhibitory function on bone resorption. As alveolar bone of young rats undergoes continuous and intense remodeling to accommodate the growing and erupting tooth, it is a suitable in vivo model for using to study the possible action of estrogen on bone. Thus, in an attempt to investigate the possibility that estrogen may induce the death of osteoclasts, we examined the alveolar bone of estrogen-treated rats.Fifteen, 22-d-old female rats were divided into estrogen, sham and control groups. The estrogen group received estrogen and the sham group received corn oil used as the dilution vehicle. After 8 d, fragments containing alveolar bone were removed and processed for light microscopy and transmission electron microscopy. Sections were stained with hematoxylin and eosin and tartrate-resistant acid phosphatase (TRAP)-an osteoclast marker. Quantitative analysis of the number of TRAP-positive osteoclasts per mm of bone surface was carried out. For detecting apoptosis, sections were analyzed by the Terminal deoxynucleotidyl transferase-mediated dUTP Nick-End Labeling (TUNEL) method; TUNEL/TRAP combined methods were also used.The number of TRAP-positive osteoclasts per mm of bone surface was significantly reduced in the estrogen group compared with the sham and control groups. TRAP-positive osteoclasts exhibiting TUNEL-positive nuclei were observed only in the estrogen group. In addition, in the estrogen group the ultrastructural images revealed shrunken osteoclasts exhibiting nuclei with conspicuous and tortuous masses of condensed chromatin, typical of apoptosis.Our results reinforce the idea that estrogen inhibits bone resorption by promoting a reduction in the number of osteoclasts, thus indicating that this reduction may be, at least in part, a consequence of osteoclast apoptosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mesobolivar luteus (Keyserling 1891) and Micropholcus fauroli (Simon 1887) specimens were collected in Ubatuba and Rio Claro, both in the state of São Paulo, Brazil. Mesabolivar luteus showed 2n (male) = 15 = 14 + X and 2n (9) = 16 = 14 + XX in mitotic metaphases and 711 + X in diplotenic cells. During late prophage 1, all bivalents presented a ring shape, evidencing two chiasmata per bivalent. In this species, some diplotenic cells appear in pairs, maybe due to specific characteristics of the intercellular bridges. The metaphases 11 showed n = 7 or n = 8 = 7 + X chromosomes. Micropholcus fauroti evidenced 2n (male) = 17 = 16 + X in spermatogonial metaphases and 8II+X in diplotenic cells, with only one chiasma per bivalent, contrasting with M. luteus. In both species, all chromosomes were metacentrics. The sexual chromosome X was the largest element and appeared as a univalent during meiosis I. These are the first cytogenetical data for the genera Mesabolivar and Micropholcus. Additionally, M. luteus is the first chromosomally analyzed species of the New World clade and the observed diploid number for M. fauroti had not yet been recorded in Pholcidae.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work we implement the spontaneous breaking of lepton number in version II of the 3-3-1 models and study their phenomenological consequences. The main result of this work is that our majoron is invisible even though it belongs to a triplet representation by the 3-3-1 symmetry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have determined the copy number and the presence of full-size hobo transposable elements in eight Brasilian strains of Drosophila melanogaster. Genomic DNA was digested with AvaII and XhoI restriction enzymes, respectively, and probed with a 963 bp sequence of the hobo element. Variable numbers of full-sized and defective elements were detected in all strains. The range of the copy number was 22.13 +/- 4.52. Blots showed the presence of a 2.6 kb fragment, corresponding to the complete element, in all strains exception of one and the 1.0 kb sequence, correponding to the Th1 and Th2 repressor elements. There was neither association among copy numbers of hobo elements and latitude nor the mean annual temperatures in the original geographical region of each strain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Platelet function and plasma fibrinogen levels were evaluated in 14 patients, 10 males and 4 females, aged 13-59 years bitten by Bothrops genus snakes. There was a statistical difference (p < 0.05) among plasma fibrinogen levels evaluated 24 and 48 hours after envenomation. There was a tendency towards normalization after 48 hours of treatment. The low platelet number was clear in 24-48 hour evaluations with a tendency towards normalization after 48 hours of treatment (p < 0.05). When platelet function was stimulated by collagen and epinephrine, it appeared to be within normal values. On the other hand, when it was stimulated by adenosine diphosphate (ADP), platelet function was hypoaggregated by a single micromol concentration until 48 hours after treatment. At a 3 micromol concentration, there were alterations only before specific treatment (p < 0.05). Fibrinogen levels and fibrin degradation product (FDP) levels appeared to be altered in 83.33% of patients evaluated. The authors suggest that platelet hypoaggregation is related to decreased fibrinogen and increased FDP levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Copepod assemblages from two cascade reservoirs were analyzed during two consecutive years. The upstream reservoir (Chavantes) is a storage system with a high water retention time (WRT of 400 days), and the downstream one (Salto Grande) is a run-of-river system with only 1. 5 days WRT. Copepod composition, richness, abundance, and diversity were correlated with the limnological variables and the hydrological and morphometric features. Standard methods were employed for zooplankton sampling and analysis (vertical 50-μm net hauls and counting under a stereomicroscope). Two hypotheses were postulated and confirmed through the data obtained: (1) compartmentalization is more pronounced in the storage reservoir and determines the differences in the copepod assemblage structure; and (2) the assemblages are more homogeneous in the run-of-river reservoir, where the abundance decreases because of the predominance of washout effects. For both reservoirs, the upstream zone is more distinctive. In addition, in the smaller reservoir the influence of the input from tributaries is stronger (turbid waters). Richness did not differ significantly among seasons, but abundance was higher in the run-of-river reservoir during summer. © 2012 Springer Science+Business Media Dordrecht.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the influence of air abrasion tips and system operation modes on enamel cutting. Methods: Forty bovine teeth were abraded with the air abrasion system Mach 4.1 for 10 and 15 seconds, employing conventional and sonic tips of 0.45-mm inner diameter and a 90° angle, and 27.5-μm aluminum oxide at 5.51 bar air pressure in continuous and pulsed modes. The width and depth of the resulting cuts were measured in SEM. Results: The multivariate analysis of variances revealed that, compared to the sonic tip, the conventional tip produced shallower cuts independent of the operation mode and the application period. Conclusions: The cutting patterns observed in this study suggest that the pulsed mode produced deeper cuts when both the conventional and sonic tips were used, and that the sonic tip cut more dental tissue than the conventional one.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine the number of podocyte, slit diaphragms, slit diaphragm extensions and GBM thickness in diabetic nephropathy. Methods: Sixty Rattus Wistarof both sexes weighing 200-300g were divided in two experimental groups: normal group 10 animals, and alloxan diabetic rats - 50 animals. Alloxan was administered in a single IV dose of 42mg/kg body weight. Body weight, water and food intake, diuresis, and blood and urine glucose were determined in both groups before alloxan injection and two weeks, six and twelve months after alloxan injection. Proteinuria was measured at 12 months in both groups. After 12 months animals were sacrificed, and the right kidney processed for electron microscopy. Results: Clear clinical and laboratory signs of severe diabetes were seen, in all alloxan-diabetic rats at all follow-up times. Glomerular basement membrane (GBM) thickening, podocyte number, and slit diaphragm number and extension were determined. GBM of all diabetic rats was significantly thicker (median=0.29μm; semi-interquartile range=0.065μm) than in the normal rats (0.23μm; 0.035μm). Diabetic rat podocyte number (8; 1), slit diaphragm number (4; 1), and slit diaphragm extension (0.021μm; 0.00435μm) were significantly lower than in normal rats (11; 1) and (7; 1.5), and (0.031μm; 0.0058μm). Diabetic rat proteinuria (0.060mg/24h; 0.037mg/24h) was higher than in normal rats (0.00185mg/24h; 0.00055mg/24h). Conclusion: Experimental diabetes is associated with significant (p<0.05) changes in podocyte foot process, slit number, slit diaphragm extension, and GBM thickness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to the renewed interest in distributed generation (DG), the number of DG units incorporated in distribution systems has been rapidly increasing in the past few years. This situation requires new analysis tools for understanding system performance, and taking advantage of the potential benefits of DG. This paper presents an evolutionary multi-objective programming approach to determine the optimal operation of DG in distribution systems. The objectives are the minimization of the system power losses and operation cost of the DG units. The proposed approach also considers the inherent stochasticity of DG technologies powered by renewable resources. Some tests were carried out on the IEEE 34 bus distribution test system showing the robustness and applicability of the proposed methodology. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, a mathematical model to analyze the impact of the installation and operation of dispersed generation units in power distribution systems is proposed. The main focus is to determine the trade-off between the reliability and operational costs of distribution networks when the operation of isolated areas is allowed. In order to increase the system operator revenue, an optimal power flow makes use of the different energy prices offered by the dispersed generation connected to the grid. Simultaneously, the type and location of the protective devices initially installed on the protection system are reconfigured in order to minimize the interruption and expenditure of adjusting the protection system to conditions imposed by the operation of dispersed units. The interruption cost regards the unsupplied energy to customers in secure systems but affected by the normal tripping of protective devices. Therefore, the tripping of fuses, reclosers, and overcurrent relays aims to protect the system against both temporary and permanent fault types. Additionally, in order to reduce the average duration of the system interruption experienced by customers, the isolated operation of dispersed generation is allowed by installing directional overcurrent relays with synchronized reclose capabilities. A 135-bus real distribution system is used in order to show the advantages of using the mathematical model proposed. © 1969-2012 IEEE.