33 resultados para measurement of time interval

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: the purpose of this study was to investigate the penetration of a conventional adhesive material into enamel bleached with 16% carbamide peroxide and 38% hydrogen peroxide using optical light microscopy.Methods: Extracted human teeth were randomly divided into eight experimental groups with six specimens each, according to the bleaching material and time interval after bleaching and before the bonding procedure. Groups were designated as follows: control group, restorations in unbleached teeth; restorations performed immediately after bleaching; restorations performed 7 days after bleaching; restorations performed 14 days after bleaching; and restorations performed 30 days after bleaching. The length of resin tags was measured with an Axiophot photomicroscope at 400x magnification for the calculation of the proportion of tags of study groups compared to the respective control groups. Analysis of variance was applied for comparison between groups; data were transformed into arcsine (p < 0.05).Results: the specimens of experimental groups, in which restorations were performed 7, 14, and 30 days after bleaching, showed better penetration of adhesive material into enamel than specimens restored immediately after bleaching. There was no statistically significant difference between the bleaching materials employed or in the interaction between bleaching agent and time interval.Conclusions: This suggests that a time interval of at least 7 days should be allowed between enamel bleaching and placement of adhesive bonding agents for accomplishment of composite resin restorations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to assess penetration of adhesive material in enamel bleached with 35% hydrogen peroxide using optical polarized light microscopy. Extracted human teeth were randomly assigned to 5 groups, each representing a specific time interval between bleaching and the application of an adhesive material. They were designated as: (TC) the control group-restorations in unbleached teeth; (T0) comprising restorations carried out immediately after bleaching; (T7) comprising restorations 7 days after bleaching; (T14) comprising restorations 14 days after bleaching; and (T21) comprising restorations 21 days after bleaching. Length of resin tags was measured with an Axiophot photomicroscope at a x 400 magnification, and the results subjected to an ANOVA for a comparison between groups, with a p value of < 0.05. Differences between the groups were verified using a Tukey test at a confidence level of 5%. The specimens in the control group (TC) and experimental groups T7, T14 and T21 showed better penetration of adhesive material into enamel in comparison with experimental group T0. This suggests that a gap of at least 7 days should be left between bleaching enamel with 35% hydrogen peroxide and placing adhesive bonding agents and undertaking resin composite restoration work.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe an experimental procedure to probe the validity of Newton's second law. The experimental arrangement allows us to accelerate a glider on an air track by means of forces that are both steady and known. We also show how to determine acceleration from average speeds calculated for successive time intervals of the motion measured by using several electronic counters connected to a single-crystal oscillator circuit. Within experimental errors, the experiments clearly show the proportionality between acceleration and force for a fixed mass and between acceleration and inverse of mass for a fixed force. © by the Sociedade Brasileira de Física.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The real-time monitoring of events in an industrial plant is vital, to monitor the actual conditions of operation of the machinery responsible for the manufacturing process. A predictive maintenance program includes condition monitoring of the rotating machinery, to anticipate possible conditions of failure. To increase the operational reliability it is thus necessary an efficient tool to analyze and monitor the equipments, in real-time, and enabling the detection of e.g. incipient faults in bearings. To fulfill these requirements some innovations have become frequent, namely the inclusion of vibration sensors or stator current sensors. These innovations enable the development of new design methodologies that take into account the ease of future modifications, upgrades, and replacement of the monitored machine, as well as expansion of the monitoring system. This paper presents the development, implementation and testing of an instrument for vibration monitoring, as a possible solution to embed in industrial environment. The digital control system is based on an FPGA, and its configuration with an open hardware design tool is described. Special focus is given to the area of fault detection in rolling bearings. © 2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Impurity interstitial atoms present in metals with BCC structure can diffuse in the metallic matrix by jumps to energetically equivalent crystallographic sites. Anelastic spectroscopy (internal friction) is based on the measurement of mechanical loss or internal friction as a function of temperature. Due to its selective and nondestructive nature, anelastic spectroscopy is well suited for the study of diffusion of interstitial elements in metals. Internal friction measurements were made using the torsion pendulum technique with oscillation frequency of a few Hz, temperature interval from 300 to 700 K, heating rate of about 1 K/min, and vacuum better than 10-5 mbar. The polycrystalline Nb and Ta samples used were supplied by Aldrich Inc. The results obtained showed thermally activated relaxation structures due to stress-induced ordering of oxygen atoms around the Nb (or Ta) atoms of the metallic matrix. The results were interpreted by three methods and led to activation enthalpy values for the diffusion of oxygen in Nb and Ta of 1.15 eV and 1.10 eV, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It was analyzed in this work the influence of photoperiod on time interval from ovulation induction period to extrusion of ovocits in female bullfrogs (Lithobates catesbeianus). It was used 54 females reared from metamorphosis to 9 months of age under three photoperiods: dark time (DL 0:24), 16 hours of daylight (DL 16:8) and 12 hours of daylight (DL 12:12). Ovulation was induced by intramuscular application of two doses of LHRHa with 12 hours of interval between the injections. After 10, 25, 28, 31, 34 and 37 hours from the first hormone injection, 10-gram samples (3,000 eggs) were extracted from each female at each time interval and fertilized. Egg hatching rate was checked in each sample 72 hours after fertilization. Analysis of variance showed a significant effect of extrusion delay and the interaction between photoperiod and this delay. Extrusion should be carried out 33, 24 and 26 hours after the first hormone dosage in females reared in environments without light, with 12 hours of daylight and with 16 hours of daylight, respectively, to obtain the maximum fertilization rate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the shrinkage of a microhybrid dental composite resin photo-activated by one LED with different power densities by means of speckle technique. The dental composite resin Filtek (TM) Z-250 (3M/ESPE) at color A(2) was used for the samples preparation. Uncured composite was packed in a metallic mold and irradiated during 20 s from 100 to 1000 mW cm(-2). For the photo-activation of the samples, it was used a LED prototype (Light Emission Diode) with wavelength centered at 470 nm and adjustable power density until 1 W cm(-2). The speckle patterns obtained from the bottom composite surfaces were monitored using a CCD camera without lens. The speckle field is recorded in a digital picture and stored by CCD camera as the carrier of information on the displacement of the tested surface. The calculated values were obtained for each pair of adjacent patterns and the changes in speckle contrast as a function of time were obtained from six repeated measurements. The speckle contrasts obtained from the bottom surface with 100 mW cm(-1) were smaller than those than the other power densities. The higher power densities provided the higher shrinkage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a study of the decay B-s(0)-> J/psi phi. We obtain the CP-odd fraction in the final state at time zero R-perpendicular to = 0.16 +/- 0.10 (stat) +/- 0.02(syst), the average lifetime of the (B-s(0), (B) over bar (0)(s)) system, (tau) over bar (B-s(0)) = 1.39(-0.16)(+0.13)(stat)(-0.02)(+0.01)(syst) ps, and the relative width difference between the heavy and light mass eigen-states, Delta Gamma/(Gamma) over bar = (Gamma(L) - Gamma(H))/(Gamma) over bar = 0.24(-0.38)(+0.28)(stat)(-0.04)(+0.03)(syst). With the additional constraint from the world average of the B-s(0) lifetime measurements using semileptonic decays, we find (tau) over bar (B-s(0)) = 1.39 +/- 0.06 ps and Delta Gamma/(Gamma) over bar = 0.25(-0.15)(+0.14). For the ratio of the B-s(0) and B-0 lifetimes we obtain (tau) over bar (B-s(0))/tau(B-s(0)) = 0.91 +/- 0.09(stat) +/- 0.003(syst).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have performed the first direct measurement of the time-integrated flavor untagged charge asymmetry in semileptonic B-s(0) decays A(SL)(s,unt) by comparing the decay rate of B-s(0) -> mu(+) D-s(-) nu X, where D-s(-) -> phi pi(-) and phi -> K+K-, with the charge-conjugate (B) over bar (0)(s) decay rate. This sample was selected from 1: 3 fb(-1) of data collected by the D0 experiment in run II of the Fermilab Tevatron collider. We obtain A(SL)(s,unt) = [1.23 +/- 0.97(stat) +/- 0.17(syst)] x 10(-2). Assuming that Delta m(s)/(Gamma) over bar (s) >> 1, this result can be translated into a measurement of the CP-violating phase in B-s(0) mixing: Delta Gamma(s)/Delta m(s) tan phi(s) = [2.45 +/- 1.93(stat) +/- 0.35(syst)] x 10(-2).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)