12 resultados para joint hypothesis tests
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper presents an approach for structural health monitoring (SHM) by using adaptive filters. The experimental signals from different structural conditions provided by piezoelectric actuators/sensors bonded in the test structure are modeled by a discrete-time recursive least square (RLS) filter. The biggest advantage to use a RLS filter is the clear possibility to perform an online SHM procedure since that the identification is also valid for non-stationary linear systems. An online damage-sensitive index feature is computed based on autoregressive (AR) portion of coefficients normalized by the square root of the sum of the square of them. The proposed method is then utilized in a laboratory test involving an aeronautical panel coupled with piezoelectric sensors/actuators (PZTs) in different positions. A hypothesis test employing the t-test is used to obtain the damage decision. The proposed algorithm was able to identify and localize the damages simulated in the structure. The results have shown the applicability and drawbacks the method and the paper concludes with suggestions to improve it. ©2010 Society for Experimental Mechanics Inc.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
To design connections between timber parts with metal dowels (nails or bolts), two phenomena must be considered: bending of the metal dowel and the embedment strength in the wood. The Brazilian Standard ABNT NBR 7190:1997 proposes the methods used in the laboratory tests to determine the embedment strength with the metal dowell and, in the absence of testing, specifies relations to calculate the embedment strength from the compression strength. The aim of this research was to compare the embedment strength values obtained by experimental tests and calculated by the relationships established by the Brazilian Standard ABNT NBR 7190:1997. By the results of the hypothesis tests, it was possible to conclude that the estimate of the embedment strength parallel to the grain proposed by the Brazilian standard ABNT NBR 7190:1997, establishing equivalence with the strength compression results in the same direction, must be effective to the wood species Pinus taeda L., however, the same was not found in the perpendicular direction with respect to the grain, possibly explained by the alpha(e) values in the equation to calculed fe(90)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Muscle strength assessment among children and adolescents with growing pains and joint hypermobility
Resumo:
OBJETIVO: Avaliar, por meio de teste quantitativo, a força muscular em crianças e adolescentes com dores de crescimento, associada ou não com hipermobilidade articular e comparadas com controles saudáveis. MÉTODO: Quarenta e sete casos de crianças e adolescentes acompanhados por dores de crescimento, sendo 24 com hipermobilidade articular (DC-HA), 23 sem hipermobilidade articular (DC) e 47 controles saudáveis pareados por idade e gênero foram submetidos a dois testes quantitativos para a avaliação da força muscular, o Childhood Myositis Assessment Scale (CMAS) e o Manual Muscle Strength Test (MMT). Os dados antropométricos como altura, peso, índice de massa corporal, prega cutânea tricipital, circunferência média do braço e a área muscular do braço foram comparados entre os três grupos. RESULTADOS: Os três grupos não apresentaram diferença estatística entre as medidas antropométricas. Houve diferença significante entre a mediana da pontuação do CMAS, sendo menores no grupo DC (47, mínimo e máximo 39-52) e DC-HA (46, mínimo e máximo 40-51), comparados com controles (50, mínimo e máximo 45-52; p<0,0001). Dois dos exercícios cronometrados do CMAS, a elevação da cabeça e a duração da elevação das pernas, tiveram menor pontuação nos pacientes comparados aos controles (p<0.0001). A pontuação mediana do MMT no grupo DC (79, mínimo e máximo 73-80) e DC-HA (78, mínimo e máximo 32-80) também apresentou diferença significante, sendo menor nos pacientes que nos controles (80, mínimo e máximo 78-80; p<0,0001). A melhor correlação entre a pontuação do CMAS e MMT foi no grupo DC-HA (Spearman r=0,65; p=0,0007). A aplicação do CMAS e MMT em duas ocasiões apresentou boa concordância e coeficiente de correlação intraclasse de 0,87 (IC 95% 0,64-0,96; p<0,0001) e 0,92 (IC 95% 0,76-0,97; p<0,0001), respectivamente. CONCLUSÃO: Os pacientes com dores de crescimento com ou sem hipermobilidade articular apresentaram fraqueza muscular de leve a moderada quando comparados com controles saudáveis.
Resumo:
Background. The authors compared the efficacy of bilateral balanced and canine guidance (occlusal) splints in the treatment of temporomandibular joint (TMJ) pain in subjects who experienced joint clicking with a nonoccluding splint in a double-blind, controlled randomized clinical trial.Methods. The authors randomly assigned 57 people with signs of disk displacement and TMJ pain into three groups according to the type of splint: bilateral balanced, canine guidance and nonoccluding. The authors followed the groups for six months using analysis of a visual analog scale (VAS), palpation of the TMJ and masticatory muscles, mandibular movements and joint sounds. They used repeated analysis of variance and a XI test to test the hypothesis.Results. The type of guidance used did not influence the pain reduction; yet both occlusal splints were superior to the nonoccluding splint, on the basis of the VAS. Despite similar outcomes in relation to opening, left; lateral and protrusive movements, TMJ and muscle pain on palpation, subjects who used the occlusal splints had improved clinical outcomes. The frequency of joint noises decreased over time, with no significant differences among groups. Subjects in the groups using the occlusal splints reported more comfort.Conclusion. The type of lateral guidance did not influence the subjects'; improvement: All of the subjects had a general improvement on the VAS, though subjects in the occlusal splint groups had better results that did subjects in the nonoccluding splint group.
Resumo:
Marfan syndrome (MFS) is an autosomal dominant trait due to mutations in the fibrillin gene (FBN1). The MFS expressivity is variable, and its diagnosis relies completely on clinical criteria. Atypical cases and Marfan- like (marfanoid) clinical presentations are commonly found. The metacarpophalangeal pattern profile (MCPP), a radiological method in which the 19 tubular hand bones are assessed, has been used in the diagnosis of various syndromes. To investigate whether the MCPP was adequate to discriminate between MFS and Marfan-like subjects, we studied 38 patients who were referred to our service because they had an MFS diagnosis, diagnostic hypothesis, or differential diagnosis or had arachnodactyly with dolichostenomelia. Two groups were formed: 1) MFS: 21 patients with a mean age of 18.3 (10.8 S.D.) years and 2) Marfan-like syndromes: 16 patients who did not meet the current criteria, with a mean age of 14.6 (4.6 S.D.) years. The MCPP was performed in each case following the classical technique, and a characteristic mean profile was obtained for group I (MFS), with Z scores ranging from 0.69 to 2.73 (1.80 ± 0.50; mean ± S.D.). In group I, three cases had no correlation with the typical MFS pattern. In group II, three cases had an MFS pattern. The correlation with the mean MCPP of MFS permitted the differential diagnosis of MFS and marfanoid syndromes with 86% sensitivity, 81% specificity, and 86% positive and 81% negative predictive values. The results suggest that MCPP can be used effectively as an auxiliary tool in the nosology of these conditions and, because there is no change in MCPP with age, can be helpful in early diagnosis.
Resumo:
The venom glands of worker ants of the species Ectatomma quadridens morphologically resemble an elongated sac or reservoir ending in a narrower portion that has the function of releasing the secretion to the exterior. Two external secretory filaments are individually inserted into the proximal portion of the gland and end inside the convoluted gland. The venom gland of workers of E. quadridens is, therefore, morphologically subdivided into four distinct portions: a) sac-shaped reservoir measuring approximately 1mm in length; b) excretory duct, proximal portion of the reservoir that joins the gland to the sting apparatus; c) convoluted gland, final portion of the external secretory filaments located inside the reservoir; and d) two secretory filaments measuring about 2 mm in length; their free extremities end blindly and are individually inserted into the reservoir wall at the proximal region of the venom gland. The histological data showed that the filaments and the convoluted gland are composed of cubic cells of secretory function. The reservoir consists of a simple cubical epithelium externally surrounded by muscle fibers. A thick cuticle internally coats the epithelium of the reservoir. The application of histochemical tests allowed us to establish that the final secretion of the venom gland of Ectatomma quadridens is of glycoproteic nature. This secretion undergoes several modifications at the secretory filaments, at the convoluted gland, and in the reservoir before reaching the excretory duct, the point at which the secretion is released in its final composition, namely the venom. Based on the differences among various Ponerinae species we propose a hypothesis suggesting a probable evolutionary process that the venom glands of members of this subfamily might have undergone.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)