40 resultados para infra sound
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Swallowing dynamics involves the coordination and interaction of several muscles and nerves which allow correct food transport from mouth to stomach without laryngotracheal penetration or aspiration. Clinical swallowing assessment depends on the evaluator's knowledge of anatomic structures and of neurophysiological processes involved in swallowing. Any alteration in those steps is denominated oropharyngeal dysphagia, which may have many causes, such as neurological or mechanical disorders. Videofluoroscopy of swallowing is presently considered to be the best exam to objectively assess the dynamics of swallowing, but the exam needs to be conducted under certain restrictions, due to patient's exposure to radiation, which limits periodical repetition for monitoring swallowing therapy. Another method, called cervical auscultation, is a promising new diagnostic tool for the assessment of swallowing disorders. The potential to diagnose dysphagia in a noninvasive manner by assessing the sounds of swallowing is a highly attractive option for the dysphagia clinician. Even so, the captured sound has an amount of noise, which can hamper the evaluator's decision. In that way, the present paper proposes the use of a filter to improve the quality of audible sound and facilitate the perception of examination. The wavelet denoising approach is used to decompose the noisy signal. The signal to noise ratio was evaluated to demonstrate the quantitative results of the proposed methodology. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
JUSTIFICATIVA E OBJETIVOS: O pinçamento infra-renal da aorta abdominal pode produzir alterações renais. O objetivo do estudo foi avaliar os efeitos do halotano, isoflurano e sevoflurano sobre a função renal, em cães submetidos a pinçamento aórtico infra-renal. MÉTODO: O estudo aleatório foi realizado em 30 cães, distribuídos em três grupos, de acordo com o anestésico halogenado utilizado durante a anestesia, em concentrações equipotentes de 0,75 CAM: GH (n = 10) - halotano a 0,67%; GI (n = 10) - isoflurano a 0,96%; e GS (n = 10) - sevoflurano a 1,8%. em todos os animais foi realizada ligadura infra-renal da aorta, por período de 30 minutos. Os atributos renais foram estudados nos momentos: C (controle), após 15 (Ao15) e 30 (Ao30) minutos de pinçamento aórtico, e após 15 (DAo15) e 30 (DAo30) minutos do despinçamento aórtico. RESULTADOS: A depuração de água livre foi menor nos grupos GI e GS, em relação ao GH, após o despinçamento aórtico (p < 0,05). Durante o pinçamento aórtico, nos três grupos, houve aumento do débito urinário, da excreção urinária de sódio e da depuração de sódio, e diminuição da osmolaridade urinária (p < 0,05). A resistência vascular renal e a fração de filtração aumentaram somente em GS (p < 0,05), enquanto a excreção fracionária de sódio aumentou em GH e GI (p < 0,05). Após o despinçamento aórtico, houve normalização dos atributos que haviam se alterado, com exceção da osmolaridade urinária, que continuou em níveis menores do que os do controle em todos os grupos (p < 0,05). A resistência vascular renal e a fração de filtração continuaram mais elevadas em GS, acompanhadas por diminuição do fluxo sangüíneo renal e da depuração de para-aminohipurato de sódio (p < 0,05). CONCLUSÕES: No cão nas condições experimentais empregadas, a inalação de halotano e isoflurano a 0,75 CAM, mas não de sevoflurano, atenuou a principal alteração após o pinçamento infra-renal da aorta, que é o aumento da resistência vascular renal.
Resumo:
JUSTIFICATIVA E OBJETIVOS: O pinçamento infra-renal da aorta abdominal pode produzir alterações hemodinâmicas. O objetivo do estudo foi avaliar os efeitos do halotano, isoflurano e sevoflurano sobre a função cardiovascular, em cães submetidos à pinçamento aórtico infra-renal. MÉTODO: O estudo aleatório foi realizado em 30 cães, distribuídos em três grupos, de acordo com o anestésico halogenado utilizado durante a anestesia, em concentrações equipotentes de 0,75 CAM: GH (n=10) - halotano a 0,67%; GI (n=10) - isoflurano a 0,96%; e GS (n=10) - sevoflurano a 1,8%. em todos os animais foi realizada ligadura infra-renal da aorta, por período de 30 min. Os atributos hemodinâmicos foram estudados nos momentos: C (Controle), Ao15 e Ao30, respectivamente após 15 e 30 minutos do pinçamento aórtico, e DAo e DAo15, respectivamente, imediatamente e após 15 min do despinçamento aórtico. RESULTADOS: Durante o pinçamento aórtico houve, em todos os grupos, aumento das pressões arterial média e do átrio direito, e dos índices cardíaco, sistólico e de trabalho sistólico dos ventrículos direito e esquerdo. A pressão da artéria pulmonar aumentou em GI e GS e a pressão pulmonar ocluída em GH e GI. Após o despinçamento aórtico, houve normalização dos atributos que haviam se elevado, com exceção dos índices cardíaco e sistólico, que continuaram elevados, acompanhados de diminuição do índice de resistência vascular sistêmica. Não houve diferença significante entre os grupos em relação aos atributos estudados, com exceção da freqüência cardíaca que foi sempre menor em GH, em relação aos demais grupos, durante o pinçamento e despinçamento aórtico. CONCLUSÕES: No cão, nas condições experimentais empregadas, a inalação do halotano, isoflurano e sevoflurano em concentrações equipotentes (0,75 CAM) não atenua as respostas cardiovasculares ao pinçamento aórtico infra-renal.
Resumo:
JUSTIFICATIVA E OBJETIVOS: O pinçamento aórtico infra-renal pode determinar alterações cardiovasculares. A clonidina, um alfa2-agonista, determina bradicardia e diminuição da pressão arterial. O objetivo do estudo foi avaliar os efeitos da clonidina sobre a função cardiovascular, em cães submetidos a pinçamento aórtico infra-renal. MÉTODO: O estudo aleatório foi realizado em 16 cães, distribuídos em dois grupos: G Controle - sem a utilização de clonidina e G Clon - clonidina, na dose inicial de 5 µg.kg-1, por via venosa, imediatamente antes do pinçamento aórtico infra-renal, seguido de 2 µg.min-1.m² até o final do estudo. em todos os animais foi realizada ligadura infra-renal da aorta, por 45 minutos. Os atributos hemodinâmicos foram estudados nos momentos C (controle), após 10 (Ao10) e 25 (Ao25) minutos do pinçamento aórtico, e após 10 (DAo10) e 25 (DAo25) minutos do despinçamento aórtico. RESULTADOS: Durante o pinçamento aórtico, houve diferença significante entre os grupos, em relação à freqüência cardíaca, pressão arterial média e índice cardíaco (G Controle > G Clon). Após o despinçamento aórtico houve diferença significante entre os grupos, em relação à freqüência cardíaca (G Controle > G Clon) e pressões do átrio direito e da artéria pulmonar ocluída (G Clon > G Controle). Durante o pinçamento aórtico, houve nos dois grupos, aumento significante das pressões de átrio direito e artéria pulmonar ocluída, dos índices sistólico e do trabalho sistólico do ventrículo esquerdo, e diminuição do índice de resistência vascular pulmonar. No grupo controle houve aumento significante das pressões arterial média e da artéria pulmonar, e dos índices cardíaco e do trabalho sistólico do ventrículo direito. No grupo clonidina, houve diminuição significante da freqüência cardíaca. Após o despinçamento aórtico, houve nos dois grupos: diminuição significante da freqüência cardíaca e pressão arterial média, enquanto os valores das pressões do átrio direito e índice sistólico continuaram elevados. No grupo controle, os valores do índice de trabalho sistólico do ventrículo direito continuaram elevados enquanto os valores do índice cardíaco retornaram a valores próximos aos do controle. No grupo clonidina, os valores das pressões do átrio direito e da artéria pulmonar ocluída, e o índice sistólico, continuaram significantemente elevados. CONCLUSÕES: No cão, nas condições experimentais empregadas, a administração venosa contínua de clonidina atenua as respostas cardiovasculares decorrentes do pinçamento aórtico infra-renal.
Resumo:
Some properties of the volatile anesthetics, such as vasodilatation and myocardial depression, combined with the sympathetic inhibition that alpha 2-agonists can produce may determine hemodynamic alterations during aortic, surgery. The interaction between dexmedetomidine (DEX), an alpha 2-agonist, and sevoflurane during aortic surgery is unknown. We studied the effects of DEX on hemodynamics and systemic oxygenation during aortic cross-clamping (Aox) and unclamping (UAox) in sevoflurane-anesthetized dogs Twenty dogs were. anesthetized with sevoflurane and were randomly assigned to two groups prior to Aox and UAox: control, n = 10, received saline infusion only, and DEX (1 mu g.kg(-1) load followed by 1 mu g.kg(-1).h(-1) infusion), n = 10. Hemodynamic and oxygenation variables were measured at baseline, after saline or DEX loading dose, 20 and 40 min after Aox, and 20 and 40 min after UAox. After DEX administration, heart rate, cardiac index l and systemic oxygen transport index (131021) were lower than in control group. Aox increased mean arterial pressure (MAP) and systemic vascular resistance index (SVRI) in both groups, but the effects were greater with DEX. Cl, heart rate, and DO(2)I were lower, while central venous pressure (CVP) and pulmonary artery occlusion pressure were higher in DEX compared to control. After UAox, MAP, CVP and SVRI were maintained higher in DEX in relation to control. We conclude that in sevoflurane-anesthetized dogs DEX alters the cardiovascular response during aortic surgery.
Resumo:
Objectives: the purpose of this study is to employ optical microscopy to measure the thickness of the hybrid layer and the penetration (tags) of an aggressive self-etching adhesive system into sound dentin.Methods: occtusat cavities were prepared in 40 extracted human posterior teeth. The prepared teeth were randomly assigned to four experimental groups with 10 specimens each. The self-etching adhesive system Adper Prompt L-Pop was applied to the dentin surface as follows: Group 1: cavosurface enamel was etched for 60 s and dentin for 20 s with 35% phosphoric acid get, immediately followed by application of the self -etching adhesive with a brush to the entire cavity for 15 s; Groups 2, 3, and 4: no pre-etching was performed, and the self -etching adhesive was applied to both enamel and dentin for 15, 30 and 45 s, respectively. After curing, the cavities were fitted with composite resin Fittek Z250. Afterwards, the teeth were decalcified and the restorations were carefully removed for later embedding in paraffin. The specimens were serially sectioned at 6 mu m of thickness and sequentially mounted in glass slides. These sections were stained with Brown and Brenn staining for posterior analysis and measurement of the hybrid layer and resin tags on a tight microscope with a micrometric ocular 40/075. The results were submitted to analysis of variance at the 5% level.Results: whenever there was significance, the Tukey test was applied at the 5% level. The specimens receiving application of acid etching before the selfetching. adhesive displayed a larger thickness of the hybrid layer; on the other hand, specimens receiving only application of the self -etching adhesive on dentin for 15, 30 and 45 s exhibited similar thickness of the hybrid layer. As regards the resin tags, no statistically significant differences could be found between the study groups.Conclusions: it could be concluded that the increase in the time of application of the self-etching adhesive Adper Prompt L-Pop did not significantly influence the formation and thickness of hybrid layer, as well as its penetration into the sound dentin surface. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The authors M. Bellamy and R.E. Mickens in the article "Hopf bifurcation analysis of the Lev Ginzburg equation" published in Journal of Sound and Vibration 308 (2007) 337-342, claimed that this differential equation in the plane can exhibit a limit cycle. Here we prove that the Lev Ginzburg differential equation has no limit cycles. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Background and Objectives. The adhesion of dental materials is important for the success of treatment. The aim of this study is to evaluate the bond strength of a composite resin applied with a self-etching adhesive system in different dentins after irradiation with Er:YAG and Nd:YAG lasers, observing their morphologic pattern using Scanning Electronic Microscopy (SEM). Materials and Methods. The buccal surface of 72 bovine incisors was worn until exposure of medium depth dentin. The specimens were divided into three groups; GI: normal, GII: demineralized and GIII: hypermineralized dentin. These were also divided into two subgroups; A-irradiated for 30 s with Er:YAG laser in noncontact mode at 40 mJ and 6 Hz and B- irradiated for 30 s with Nd:YAG laser in contact mode at 60 mJ and 10 Hz. The adhesive system Clearfil SE. Bond (Kuraray) and composite resin Tetric Ceram (Vivadent) were applied on the irradiated area by the incremental technique. After storage for 24 h in distilled water at 37 degrees C, the specimens were submitted to the shear strength test in a universal testing machine (EMIC) at a crosshead speed of 1.0 mm/min. Other specimens were made to be analyzed by SEM. Results. The results were statistically analyzed by Analysis of Variance and the Tukey test. Regardless of the type of dentin, the bond strength of specimens irradiated with the Nd:YAG laser (8,94 +/- 2,07) was higher compared to specimens irradiated with the Er:YAG laser (7,03 +/- 2,47); the highest bond strength was obtained for the group of hypermineralized dentin irradiated with the Nd:YAG laser. The SEM analysis showed that the Er:YAG laser caused opening of tubules and the Nd:YAG laser produced areas of fusion as well as regions of opening of dentinal tubules. Conclusions. The dentin showed different morphological patterns and the laser promote alterations on their surfaces, influencing the bond strength of the composite resin. (C) 2010 Laser Institute of America.
Resumo:
The addition of a topologically massive term to an admittedly nonunitary three-dimensional massive model, be it an electromagnetic system or a gravitational one, does not cure its nonunitarity. What about the enlargement of avowedly unitary massive models by way of a topologically massive term? the electromagnetic models remain unitary after the topological augmentation but, surprisingly enough, the gravitational ones have their unitarity spoiled. Here we analyze these issues and present the explanation why unitary massive gravitational models, unlike unitary massive electromagnetic ones, cannot coexist from the viewpoint of unitarity with topologically massive terms. We also discuss the novel features of the three-term effective field models that are gauge-invariant.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Sharp transitions are perhaps absent in QCD, so that one looks for physical quantities which may reflect the phase change. One such quantity is the sound velocity which was shown in lattice theory to become zero at the transition point for pure glue. We show that even in a simple bag model the sound velocity goes to zero at temperature T = T(v) not-equal 0 and that the numerical value of this T(v) depends on the nature of the meson. The average thermal energy of mesons goes linearly with T near T(v), with much smaller slope for the pion. The T(v) - s can be connected with the Boltzmann temperatures obtained from transverse momentum spectrum of these mesons in heavy-ion collision at mid-rapidity. It would be interesting to check the presence of different T(v) - s in present day finite T lattice theory.