579 resultados para dental prosthesis

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study is to describe the degree of yeast-colonization in diabetic and hemodialysed-users of dental prostheses. Individuals (306) were examined using an oral rinse technique in order to evaluate the incidence of yeast-carriage, and genotype of C. albicans. Yeasts were isolated from 68.4% (91/133) individual's dental prostheses users. Dental prostheses were found to be a significant factor for the yeast colonization (P < 0.05). Overall, the intensity of carriage was higher in diabetic patients as compared with health and hemodialysed individuals (P < 0.05). The isolation rates were: C. albicans (51.7%), C. parapsilosis (20.9%), C. tropicalis (14.3%), C. glabrata (6.6%), C. krusei (3.3%), C. rugosa (1.1%), and Pichia (Pichia ohmeri, 2.2%). Ready-To-Go RAPD Analysis Beads were used and primer OPJ 6 distinguished the C. albicans isolates found in prostheses users. All the isolates were grouped into 11 RAPD profiles in four main clusters and, the average S (AB) for the entire collection of 47 C. albicans isolates were 0.779 +/- 0.178. Over 85% of isolates had a similarity level higher than or equal to 0.8 reinforcing the idea that the use of dental prostheses, independently of the host's clinical condition, probably provides the necessary conditions for these strains to gain a growth-specific advantage over others.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. Considering that patients' satisfaction is one of the most important goals in conducting removable dental prosthesis (RDP) therapy and the fact that there are many factors which influence this parameter, the present study aims to evaluate the expectation before and satisfaction after therapy with RDP in patients who seek such therapy. As a secondary objective, other variables that may be associated with patient satisfaction are also evaluated, such as gender, age, Kennedy's classification of the arch supporting the RDP, the number of RDP adjustments after delivery and patients' evaluation of the dentists' conduct. Materials and methods. A sample of 44 patients who received RDP therapy were assigned visual analog scale scores for their expectation before and satisfaction after therapy regarding chewing, aesthetics, comfort and phonetics. They also completed a questionnaire concerning the dentists' conduct. Results. There was no statistically significant difference among scores concerning different genders, age, number of post-delivery settings and arch involved in the RDP. Regarding patients' evaluation of the dentists' conduct, there was a predominance of positive evaluations, but only different answers to the statement (i.e. 'The dentist I saw thoroughly explained the recommended treatment before it commenced') present statistically significant different scores for chewing (p = 0.040) and phonetics (p = 0.046). Conclusions. The average visual analog scale scores were high for both expectation prior to treatment and satisfaction after treatment; however, the scores for expectations were higher than those for satisfaction. © 2013 Informa Healthcare.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: This three-dimensional finite element analysis study evaluated the effect of different material combinations on stress distribution within metal-ceramic and all-ceramic single implant-supported prostheses. Materials and Methods: Three-dimensional finite element models reproducing a segment of the maxilla with a missing left first premolar were created. Five groups were established to represent different superstructure materials: GP, porcelain fused to gold alloy; GR, modified composite resin fused to gold alloy; TP, porcelain fused to titanium; TR, modified composite resin fused to titanium; and ZP, porcelain fused to zirconia. A 100-N vertical force was applied to the contact points of the crowns. All models were fixed in the superior region of bone tissue and in the mesial and distal faces of the maxilla section. Stress maps were generated by processing with finite element software. Results: Stress distribution and stress values of supporting bone were similar for the GP, GR, TP, and ZP models (1,574.3 MPa, 1,574.3 MPa, 1,574.3 MPa, and 1,574.2 MPa, respectively) and different for the TR model (1,838.3 MPa). The ZP model transferred less stress to the retention screw (785 MPa) than the other groups (939 MPa for GP, 961 MPa for GR, 1,010 MPa for TP, and 1,037 MPa for TR). Conclusion: The use of different materials to fabricate a superstructure for a single implant-supported prosthesis did not affect the stress distribution in the supporting bone. The retention screw received less stress when a combination of porcelain and zirconia was used. Int J Oral Maxillofac Implants 2011;26:1202-1209

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: To evaluate the flexural strength of two fixed dental prosthesis (FDP) designs simulating frameworks of adhesive fixed partial prostheses, reinforced or not by glass fiber.Materials and Methods: Forty specimens, made with composite resin, were divided into 4 groups according to the framework design and the presence of fiber reinforcement: A1 - occlusal support; A2: occlusal support + glass fiber; B1: occlusal and proximal supports; B2: occlusal and proximal supports + glass fiber. The specimens were subjected to the three-point bending test, and the data were submitted to two-way ANOVA and Tukey's test (5%).Results: Group A2 (97.9 +/- 38 N) was statistically significantly different from all other experimental groups, presenting a significantly lower mean flexural strength.Conclusion: The use of glass fibers did not improve the flexural strength of composite resin, and designs with occlusal and proximal supports presented better results than designs simulating only occlusal support.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: Tissue reactions to 4 different implant surfaces were evaluated in regard to the development and progression of ligature-induced peri-implantitis. Materials and Methods: In 6 male mongrel dogs, a total of 36 dental implants with different surfaces (9 titanium plasma-sprayed, 9 hydroxyapatite-coated, 9 acid-etched, and 9 commercially pure titanium) were placed 3 months after mandibular premolar extraction. After 3 months with optimal plaque control, abutment connection was performed. Forty-five days later, cotton ligatures were placed around the implants to induce peri-implantitis. At baseline and 20, 40, and 60 days after placement, the presence of plaque, peri-implant mucosal redness, bleeding on probing, probing depth, clinical attachment loss, mobility, vertical bone loss, and horizontal bone loss were assessed. Results: The results did not show significant differences among the surfaces for any parameter during the study (P > .05). All surfaces were equally susceptible to ligature-induced peri-implantitis over time (P < .001). Correlation analysis revealed a statistically significant relationship between width of keratinized tissue and vertical bone loss (r 2 = 0.81; P = .014) and between mobility and vertical bone loss (r 2 = 0.66; P = .04), both for the titanium plasma-sprayed surface. Discussion and Conclusions: The present data suggest that all surfaces were equally susceptible to experimental peri-implantitis after a 60-day period.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of this study is to survey radiographic measurement estimation in the assessment of dental implant length according to dentists' confidence. A 19-point questionnaire with closed-ended questions was used by two graduate students to interview 69 dentists during a dental implant meeting. Included were 12 questions related to over- and underestimation in three radiographic modalities: panoramic (P), conventional tomography (T), and computerized tomography (CT). The database was analyzed by Epi-Info 6.04 software and the values from two radiographic modalities, P and T, were compared using a chi2 test. The results showed that 38.24% of the dentists' confidence was in the overestimation of measurements in P, 30.56% in T, and 0% in CT. On the other hand, considering the underestimated measurements, the percentages were 47.06% in P, 33.33% in T, and 1.92% in CT. The frequency of under- and overestimation were statistically significant (chi2 = 6.32; P = .0425) between P and T. CT was the radiographic modality with higher measurement precision according to dentists' confidence. In conclusion, the interviewed dentists felt that CT was the best radiographic modality when considering the measurement estimation precision in preoperative dental implant assessment.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Control of cross-contamination between dental offices and prosthetic laboratories is of utmost importance to maintain the health of patients and dental office staff. The purpose of this study was to evaluate disinfection protocols, considering antimicrobial effectiveness and damage to the structures of prostheses. Solutions of 1% sodium hypochlorite, 2% chlorhexidine digluconate, 50% vinegar and sodium perborate were evaluated. Specimens were contaminated in vitro with standardized suspensions of Candida albicans, Streptococcus mutans, Escherichia coli, Staphylococcus aureus and Bacillus subtilis spores. Disinfection by immersion for 10. min was performed. Final counts of microorganisms were obtained using the plating method. Results were statistically compared by Kruskal-Wallis ANOVA and Dunn's test. The surface roughness of 40 specimens was analyzed before and after 10 disinfection cycles, and results were compared statistically using Student's t test. The solution of 50% vinegar was as effective as 1% sodium hypochlorite and 2% chlorhexidine against C. albicans, E. coli and S. mutans. The sodium perborate solution showed the lowest antimicrobial effectiveness. Superficial roughness increased after cycles in 1% sodium hypochlorite (p=0.02). Solutions of 1% sodium hypochlorite, 2% chlorhexidine and 50% vinegar were effective for the disinfection of heat-polymerized acrylic specimens. Sodium hypochlorite increased the superficial roughness. © 2013 King Saud Bin Abdulaziz University for Health Sciences.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of this study was to compare the release of bone markers during osseointegration of immediately loaded and nonloaded implants. Forty patients who were indicated for rehabilitation with dental implants randomly received either implant and prosthesis placement within 72 hours (group IM) or implant insertion and no prosthesis placement (group NL). Peri-implant crevicular fluid was collected immediately after implant insertion and 7, 15, 30, 60, 90, and 120 days after surgery and levels of osteoprotegerin, transforming growth factors, osteocalcin, osteopontin, and parathyroid hormone were evaluated using Luminex assay. Bleeding index and peri-implantar sulcus depth were also evaluated. The data were compared using statistical tests ( = 5%). No statistical difference was found regarding demographic and clinical parameters (p > .05). Transforming growth factors, osteoprotegerin, osteopontin, and parathyroid hormone presented an earlier release peak in group IM than in NL group (p < .05). Osteocalcin achieved higher levels in group IM versus group NL between 7 and 30 days of evaluation (p < .05). It may be concluded that earlier loading positively modulates bone mediators release around immediately loaded implants when compared with nonloaded dental implants (ClinicalTrials.gov NCT01909999).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Bone quality and quantity are important factors with regard to the survival rate of dental implants. The aim of this study was to conduct a systematic review of dental implants inserted in low-density bone and to determine the survival rate of dental implants with surface treatments over time. A systematic review of the literature was undertaken by two independent individuals; the Medline/PubMed database was searched for the period July 1975 to March 2013. Relevant reports on bone quality and osseointegration of dental implants were selected. The search retrieved 1018 references, and after inclusion and exclusion criteria were applied, 19 studies were selected for review. A total of 3937 patients, who had received a total of 12,465 dental implants, were analyzed. The survival rates of dental implants according to the bone density were: type I, 97.6%; type II, 96.2%; type III, 96.5%; and type IV, 88.8%. The survival rate of treated surface implants inserted in low-density bone was higher (97.1%) than that of machined surface implants (91.6%). Surface-treated dental implants inserted in low-density bone have a high survival rate and may be indicated for oral rehabilitation. However, more randomized studies are required to better evaluate this issue.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Head and neck tumors are a major health concern worldwide, due to their high incidence and mortality rates, particularly in developing countries. In Brazil, this type of cancer is commonly diagnosed and studies suggested that it may be the leading cause of mortality in the country. The increase in life expectancy worldwide, as well as environmental and behavioral factors, are related to carcinogenesis. Therefore, an understanding of basic epidemiology and statistical methods is critical, in order to promote early diagnosis and cancer prevention. Cancer patients with an indication for prosthesis were selected from the medical records of the Oral Oncology Center, School of Dentistry, São Paulo State University (UNESP), Araçatuba, between 1991 and 2010. The following variables were recorded: gender, age, type and location of the lesion, radiation dose and dental prosthesis. The majority of the patients were male (74.15%) and >60 years of age (53.37%). Tumors were most commonly located in the floor of the mouth (11.1%) and squamous cell carcinoma was the most prevalent type (72.8%). This study provides the profiles of patients who attended the Oral Oncology Center and the results may aid in the creation of cancer prevention programs.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to gather information and discuss the predictability of implant-supported prostheses in patients with bruxism by performing a literature review. METHODS: In order to select the studies included in this review, a detailed search was performed in PubMed and Medline databases, using the following key words: bruxism, dental implants, implant supported prosthesis, and dental restoration failure. Items that were included are: case reports, randomized controlled trials, in vitro studies, literature and systematic reviews, with or without meta-analysis, of the last 20 years that addressed the theme. Articles without abstracts, animal studies, articles in languages other than English and articles from journals unrelated to the dental field were excluded. RESULTS: after analysis according to inclusion and exclusion criteria, 28 articles were selected from a total of 54. It is known from the array of scientific articles which have assessed, either through retrospective, prospective or experimental studies, that the biomechanical and biological impact of bruxism on implant-supported prostheses is small, and that the literature has contributed little to exemplify the prosthetic limits of safety for the specialist from a clinical point of view. CONCLUSION: Although there is still no general consensus on this matter, most of the literature review articles do provide clinical guidelines that contribute to implant supported prostheses longevity and stability in patients with bruxism.