28 resultados para conjunction

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fast, simple, non-destructive method for the direct screening of polycyclic aromatic hydrocarbons (PAHs) in vegetable oil samples is proposed. The method uses a supercritical fluid extraction (SFE) system coupled on-line with a fluorimetric detector to determine PAHs. This special assembly avoids the main problems encountered in the determination of PAHs in complex matrices such as vegetable oils. PAHs are selectively extracted by using silica gel in the thimble and cleaned up by passage through a C18 column. Interferences are preferentially retained by the silica gel during the SFE process while PAHs are adsorbed in the C18 column and the remainder of the matrix is sent to waste. Finally, the C18 column is purged to remove residual CO2 gas and adsorbed PAHs are recovered by desorption with a solvent. The extracts from positive samples are subsequently analyzed by liquid chromatography (LC) with fluorescence detection. The proposed method allows the confirmation of vegetable oil safety and hence provides a new tool for consumer protection. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Testicular biopsy has been a complementary technique for clinical and research purposes to evaluate reproductive function in males. However, hemorrhage, inflammation, degeneration, and adhesion are factors that might limit the use of this procedure. In order to minimize these potential problems, fibrin glue derived from snake venom, a tissue adhesive with sealing, hemostatic, and healing properties, was used in conjunction with bilateral testicular biopsy with the Tru-Cut needle and was compared with a more conventional technique that uses nylon suture. Thirty mature rams were randomly assigned to three groups of 10 animals each, as follows: nonsurgical control group (no scrotal surgery, or biopsy); biopsy + glue group (fibrin glue on puncture sites and skin incisions) and biopsy + suture group (compression with swab on puncture sites and suturing of skin incision). The surgeries of the rams in the biopsy groups were performed on the same day, which was designated Day 0 for all three groups. Data of scrotal circumference, number of spermatozoa per ejaculum, percentage of morphologically abnormal spermatozoa, spermatozoa motility, and serum testosterone concentrations from Days -7, 20, 40, 60, 80 and 100 were evaluated. There were no significant differences between groups within days for any of the parameters evaluated. In conclusion, the testicular biopsy procedure using the Tru-Cut needle in conjunction with conventional nylon suture or the more novel fibrin glue in rams did not affect any of the parameters of testicular function evaluated in this study and was shown to be relatively simple, safe and efficient. (C) 2002 Published by Elsevier B.V. B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the influence of a sub-epithelial connective tissue graft placed at the buccal aspect of implants installed immediately after tooth extraction on the dimensional changes of hard and soft tissues. Materials and Methods: In six Labrador dogs a bilateral partial- thickness dissection was made buccal to the second mandibular premolar. At the lingual aspect, full-thickness flaps were elevated. The teeth were extracted and implants installed immediately into the distal socket. A connective tissue graft was obtained from the palate and applied to the buccal aspect of the test sites, whereas contra-laterally, no graft was applied. The flaps were sutured to allow a non-submerged installation. After 4 months of healing, the animals were sacrificed, ground sections were obtained and histomorphometric analyses were performed. Results: After 4 months of healing, all implants were integrated (n = 6). Both at the test and at the control sites bone resorption occurred: 1.6 mm and 2.1 mm, respectively. The difference was not statistically significant. The coronal aspect of the peri-implant soft tissue was wider and located more coronally at the test compared with the control sites. The differences were statistically significant. Conclusions: The application of a connective tissue graft placed at the buccal aspect of the bony wall at implants installed immediately after tooth extraction yielded a minimal preservation of the hard tissues. The peri-implant mucosa, however, was significantly thicker and more coronally positioned at the test compared with the control sites. © 2012 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estudou-se um método objetivo para a estimativa do número de frutos em pomares de laranja baseado na contagem dos frutos em ramos de 5 cm de diâmetro. Foram realizados levantamentos em laranjeiras durante três safras, obtendo-se o número de frutos produzidos em um ramo terminal, tomado ao acaso, bem como o número total na árvore. Consideraram-se nove estratos, constituídos pelas cultivares de laranja-doce, Hamlin, Pêra, Natal e Valência (as duas últimas analisadas conjuntamente) e três faixas etárias (três a cinco, seis a 10 e mais que 10 anos de idade). Foram ajustados modelos de regressão linear para o número total de frutos da árvore em função do número de frutos no ramo, obtendo-se coeficientes de determinação variando de 0,79 a 0,94. Com exceção da cultivar Hamlin, verificou-se coincidência entre as curvas das faixas etárias correspondentes. Esses resultados permitem estimar a produção média de frutos em um pomar de laranja, com base em amostragem de ramos com tamanho fixo, com precisão satisfatória, sem o uso de métodos de amostragem mais laboriosos e onerosos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article reports the nucleotide diversity within the control region of 42 mitochondrial chromosomes belonging to five South American native cattle breeds (Bos taurus). Analysis of these data in conjunction with B. taurus and B. indicus sequences from Africa, Europe, the Near East, India, and Japan allowed the recognition of eight new mitochondrial haplotypes and their relative positions in a phylogenetic network. The structure of genetic variation among different hypothetical groupings was tested through the molecular variance decomposition, which was best explained by haplotype group components. Haplotypes surveyed were classified as European-related and African-related. Unexpectedly, two haplotypes within the African cluster were more divergent from the African consensus than the latter from the European consensus. A neighbor-joining tree shows the position of two haplotypes compared to European/African mitochondrial lineage splitting. This different and putatively ancestral mitochondrial lineage (AA) is supported by the calibration of sequence divergence based on the Bos-Bison separation. The European/African mitochondria divergence might be subsequent (67,100 years before present) to that between AA and Africans (84,700 years before present), also preceding domestication times. These genetic data could reflect the haplotype distribution of Iberian cattle five centuries ago.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to develop a laboratory method for time response evaluation on electronically controlled spray equipment using Programmable Logic Controllers (PLCs). For that purpose, a PLC controlled digital drive inverter was set up to drive an asynchronous electric motor linked to a centrifugal pump on a experimental sprayer equipped with electronic flow control. The PLC was operated via RS232 serial communication from a PC computer. A user program was written to control de motor by adjusting the following system variables, all related to the motor speed: time stopped; ramp up and ramp down times, time running at a given constant speed and ramp down time to stop the motor. This set up was used in conjunction with a data acquisition system to perform laboratory tests with an electronically controlled sprayer. Time response for pressure stabilization was measured while changing the pump speed by +/-20%. The results showed that for a 0.2 s ramp time increasing the motor speed, as an example, an AgLogix Flow Control system (Midwest Technologies Inc.) took 22 s in average to readjust the pressure. When decreasing the motor speed, this time response was down to 8 s. General results also showed that this kind of methodology could make easier the definition of standards for tests on electronically controlled application equipment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Considering that counting the percentage of CD4 T lymphocytes can add prognostic information regarding patients infected with HIV, the aim of this study was to evaluate the percentage values of CD4+ T lymphocytes from 81 patients determined by flow cytometry and estimated by flow cytometry in conjunction with a hematology counter. Means were compared through the Student's t-test. Pearson's correlation was determined, and the agreement between results was tested by Bland-Altman. The level of significance was P < 0.05. It was found a significantly higher mean difference between the relative values of CD4+ T lymphocytes to the hematologic counter (P < 0.05), for all strata studied. Positive and significant correlations (P < 0.01) were found between the strata CD4 < 200 cells/mL (r = 0.93), between 200 and 500 cells/mL (r = 0.65), and >500 cells/mL (r = 0.81). The limits of agreement were 1.0 +/- 3.8% for the stratum of CD4 < 200 cells/mL, approximately 2.2 +/- 13.5% for the stratum of CD4 between 200 and 500 cells/mL, and approximately 6.2 +/- 20.4% for the stratum > 500 cells/mL. The differences in the percentages of CD4+ T lymphocytes obtained by different methodologies could lead to conflict when used in clinical decisions related to the treatment and care of people infected with HIV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study described the formulation and characterisation of the viscoelastic, mechanical and mucoadhesive properties of thermoresponsive, binary polymeric systems composed of poloxamer (P407) and poly(acrylic acid, C974P) that were designed for use as a drug delivery platform within the oral cavity. Monopolymeric and binary polymeric formulations were prepared containing 10, 15 and 20% (w/w) poloxamer (407) and 0.10-0.25% (w/w) poly(acrylic acid, 934P). The flow theological and viscoelastic properties of the formulations were determined using controlled stress and oscillatory rheometry, respectively, the latter as a function of temperature. The mechanical and mucoadhesive properties (namely the force required to break the bond between the formulation and a pre-hydrated mucin disc) were determined using compression and tensile analysis, respectively. Binary systems composed of 10% (w/w) P407 and C934P were elastoviscous, were easily deformed under stress and did not exhibit mucoadhesion. Formulations containing 15 or 20% (w/w) Pluronic P407 and C934P exhibited a sol-gel temperature T(sol/gel), were viscoelastic and offered high elasticity and resistance to deformation at 37 degrees C. Conversely these formulations were elastoviscous and easily deformed at temperatures below the sol-gel transition temperature. The sol-gel transition temperatures of systems containing 15% (w/w) P407 were unaffected by the presence of C934P; however, increasing the concentration of C934P decreased the T(sol/gel) in formulations containing 20%(w/w) P407. Rheological synergy between P407 and C934P at 37 degrees C was observed and was accredited to secondary interactions between these polymers, in addition to hydrophobic interactions between P407 micelles. Importantly, formulations composed of 20% (w/w) P407 and C934P exhibited pronounced mucoadhesive properties. The ease of administration (below the T(sol/gel)) in conjunction with the viscoelastic (notably high elasticity) and mucoadhesive properties (at body temperature) render the formulations composed of 20% (w/w) P407 and C934P as potentially useful platforms for mucoadhesive, controlled topical drug delivery within the oral cavity. (c) 2009 Published by Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A agregação plaquetária avalia a função das plaquetas através de diferentes vias de ativação plaquetária in vitro, fornecendo traçados de ondas equivalentes à propriedade física dessa agregação. Sabendo-se que a aspirina acetila irrever­sivelmente a enzima cicloxigenase prevenindo a geração de tromboxana A2, potente ativador da agregação plaquetária, esta droga tem sido analisada há mais de trinta anos na clínica médica em pacientes com doenças cardiovasculares como uma potente droga antitrombótica. Foram nossos objetivos obter traçados de ondas correspondentes às fases da agregação plaquetária para nossa padronização utilizando nosso grupo controle de doadores de sangue e compará-las com nosso grupo estudo, frente a diferentes agentes agonistas em diferentes concentrações: ADP 1µM e 3µM; AA, 0,5mM; ADR, 0,05 mg/mL, 0,025 mg/mL e 0,010 mg/mL. Os grupos analisados foram constituídos por 41 cardíacos e 40 doadores de sangue considerados controle. Dos cardíacos, 33 faziam uso regular do AAS na concentração de 200 mg/dia e oito na concentração de 100 mg/dia, sendo todos considerados hipertensos. A padronização da agregometria estava na dependência do encontro de traçados correspondentes a ondas de agregação, sendo esses obtidos em porcentagem no tempo de cinco minutos estandartizados pelo aparelho utilizado. Comparando os resultados entre os pacientes e o grupo controle, foi possível observar que, na presença dos agentes agregantes ADP 1µM e ADP 3 µM, ADR 0,05 mg/mL, 0,025mg/mL e 0,010 mg/mL, os pacientes apresentaram 1ª onda, mas não 2ª onda. Por sua vez, no caso do AA 0,5 mM não houve o encontro de traçados de ondas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The absorption edge and the bandgap transition of sol-gel-dip-coating SnO2 thin films, deposited on quartz substrates, are evaluated from optical absorption data and temperature dependent photoconductivity spectra. Structural properties of these films help the interpretation of bandgap transition nature, since the obtained nanosized dimensions of crystallites are determinant on dominant growth direction and, thus, absorption energy. Electronic properties of the bulk and (110) and (101) surfaces are also presented, calculated by means of density functional theory applied to periodic calculations at B3LYP hybrid functional level. Experimentally obtained absorption edge is compared to the calculated energy band diagrams of bulk and (110) and (101) surfaces. The overall calculated electronic properties in conjunction with structural and electro-optical experimental data suggest that the nature of the bandgap transition is related to a combined effect of bulk and (101) surface, which presents direct bandgap transition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)