70 resultados para coaxial cavity resonators

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to describe the degree of yeast-colonization in diabetic and hemodialysed-users of dental prostheses. Individuals (306) were examined using an oral rinse technique in order to evaluate the incidence of yeast-carriage, and genotype of C. albicans. Yeasts were isolated from 68.4% (91/133) individual's dental prostheses users. Dental prostheses were found to be a significant factor for the yeast colonization (P < 0.05). Overall, the intensity of carriage was higher in diabetic patients as compared with health and hemodialysed individuals (P < 0.05). The isolation rates were: C. albicans (51.7%), C. parapsilosis (20.9%), C. tropicalis (14.3%), C. glabrata (6.6%), C. krusei (3.3%), C. rugosa (1.1%), and Pichia (Pichia ohmeri, 2.2%). Ready-To-Go RAPD Analysis Beads were used and primer OPJ 6 distinguished the C. albicans isolates found in prostheses users. All the isolates were grouped into 11 RAPD profiles in four main clusters and, the average S (AB) for the entire collection of 47 C. albicans isolates were 0.779 +/- 0.178. Over 85% of isolates had a similarity level higher than or equal to 0.8 reinforcing the idea that the use of dental prostheses, independently of the host's clinical condition, probably provides the necessary conditions for these strains to gain a growth-specific advantage over others.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study described the formulation and characterisation of the viscoelastic, mechanical and mucoadhesive properties of thermoresponsive, binary polymeric systems composed of poloxamer (P407) and poly(acrylic acid, C974P) that were designed for use as a drug delivery platform within the oral cavity. Monopolymeric and binary polymeric formulations were prepared containing 10, 15 and 20% (w/w) poloxamer (407) and 0.10-0.25% (w/w) poly(acrylic acid, 934P). The flow theological and viscoelastic properties of the formulations were determined using controlled stress and oscillatory rheometry, respectively, the latter as a function of temperature. The mechanical and mucoadhesive properties (namely the force required to break the bond between the formulation and a pre-hydrated mucin disc) were determined using compression and tensile analysis, respectively. Binary systems composed of 10% (w/w) P407 and C934P were elastoviscous, were easily deformed under stress and did not exhibit mucoadhesion. Formulations containing 15 or 20% (w/w) Pluronic P407 and C934P exhibited a sol-gel temperature T(sol/gel), were viscoelastic and offered high elasticity and resistance to deformation at 37 degrees C. Conversely these formulations were elastoviscous and easily deformed at temperatures below the sol-gel transition temperature. The sol-gel transition temperatures of systems containing 15% (w/w) P407 were unaffected by the presence of C934P; however, increasing the concentration of C934P decreased the T(sol/gel) in formulations containing 20%(w/w) P407. Rheological synergy between P407 and C934P at 37 degrees C was observed and was accredited to secondary interactions between these polymers, in addition to hydrophobic interactions between P407 micelles. Importantly, formulations composed of 20% (w/w) P407 and C934P exhibited pronounced mucoadhesive properties. The ease of administration (below the T(sol/gel)) in conjunction with the viscoelastic (notably high elasticity) and mucoadhesive properties (at body temperature) render the formulations composed of 20% (w/w) P407 and C934P as potentially useful platforms for mucoadhesive, controlled topical drug delivery within the oral cavity. (c) 2009 Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: the objective of the present study was to determine the importance of the site of embryo transfer (upper or lower half endometrial cavity) on implantation and clinical pregnancy rates. METHODS: A total of 400 transfers guided by ultrasound were randomly assigned to two groups according to the distance between the uterine fundus and the catheter tip at the time of embryo placement. Group I (n=200) consisted of transfers corresponding to a distance of <50% of the endometrial cavity length (ECL), i.e. transfer in upper half of the cavity; and group II (n=200) consisted of transfers corresponding to a distance of greater than or equal to50%, of the ECL, i.e. transfer in lower half of cavity. The Student's t-test, Mann-Whitney test and Fisher's exact test were used where appropriate. RESULTS: the general characteristics of the study population and the main transfer cycle characteristics had an equal distribution (P>0.05) between groups I and II. No significant difference in implantation or pregnancy rates was observed between groups I and II. CONCLUSION: the implantation or pregnancy rates were similar whether the embryos were deposited in the upper or lower half of the endometrial cavity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We placed spheres of synthetic hydroxyapatite (calcium chloride combined with sodium phosphate) in the eviscerated or enucleated orbital cavity of rats in order to evaluate the biocompatibility of this material with the orbital cavity. The study was conducted on 50 albino rats, 25 of which were submitted to enucleation and 25 to evisceration of one eye. The animals were sacrificed 7, 15, 21, 30 and 60 days after surgery and the orbital content was submitted to histopathological examination. A reaction of the young granulation tissue type was observed first. The hydroxyapatite was gradually surrounded by a granulomatous macrophage inflammatory response and covered with dense connective tissue that formed a sort of mesh septating and supporting progressively smaller blocks of the substance. The same type of reaction was observed in the enucleated and eviscerated cavities. We conclude that synthetic hydroxyapatite is an inert nonallergenic material which is appropriate for volume replacement in the anophthalmic cavity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound.METHODS: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery.RESULTS: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27.8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues.CONCLUSION: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provides useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation,

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this study were to develop a dental chart evaluate any oral cavity disease, develop gypsum models the dental arches, and to register the occlusions found in coatis (Nasua nasua) in captivity. Formulation of the dental chart was assisted by intraoral radiographs from the head of an adult coati cadaver of the same species with the following dental formula: I 3/3, C 1/1, P 4/3, M 2/2. Seven live coatis of the Nasua nasua species were evaluated. Five of the seven coatis presented with various dental abnormalities as follows: dental plaque (71.4 %), gingivitis (71.4 %), periodontitis (57.1 %), dental stain (42.9 %), dental abrasion (57.1 %), dental fracture (57.1 %), pulp exposure (42.9 %), malocclusion (5 7.1 %) and supernumerary teeth (14.2 %).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate cellular migration induced by calcium hydroxide to air-pouch cavities in mice. The migration was more specific to neutrophil and was dose and time dependent (peaking 96 h after stimulation). This migration was inhibited by pretreatment with thalidomide, indomethacin, MK886, meloxicam, dexamethasone, MK886 associated with indomethacin, and MK886 associated with indomethacin and dexamethasone. The air-pouch exudate from animals stimulated with calcium hydroxide showed an increase of leukotriene-B4 (LTB4), interleukin-1 beta, tumor necrosis factor alpha (TNF-alpha), cytokine-induced neutrophil chemoattractant (KC), and macrophage inflammatory protein 2 (MIP-2) release. Pretreatment with 3% thioglycollate increased the macrophage population in the air pouch but did not change neutrophil migration. Depleting the resident mast cells through chronic pretreatment with compound 48/80 did not alter neutrophil migration in response to calcium hydroxide. It was possible to conclude that calcium hydroxide-induced neutrophil migration to the air-pouch cavity in mice is mediated by LTB4, TNF-alpha, KC, MIP-2, and prostaglandins, but it was not dependent on macrophages or mast cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study compared three methods of Streptococcus mutans and Lactobacillus spp. detection in the oral cavity: saliva swab (SS)-sample of stimulated saliva collected with swab; whole saliva (WS)-sample of 2 ml of stimulated saliva; and the dental plaque method (DP)-plaque sample of all dental surfaces.Methods: Thirty children were included in this study. In the first 15 children, the SS and WS methods were carried out before the dental plaque collection, and in the following 15, the sequence was inverted to evaluate possible interference of the methods sequence. The samples were diluted and inoculated in SB20 and Rogosa agar, respectively for S. mutans and Lactobacillus spp., at 37 degrees C for 48 h.Results: the results (cfu/mL) of S. mutans were analysed by the statistical Friedman's test. The levels of Lactobacillus spp. were analysed by descriptive statistics due to the high proportion of zero counts in the culture. In the first sequence of methods, the number of S. mutans counted for the SS method was inferior to DP and WS (P < 0.05), and the results for the WS and DP methods were similar. The detection of Lactobacillus spp. was observed just by the WS (100 %) and SS (14.3 %) methods. However, in the second experimental set the number of S. mutans detected by the DP method was similar to those of the SS and WS, however, the WS method showed higher values than SS (P < 0.05). A greater number of Lactobacillus spp. was detected by the WS method (100 %), followed by SS (55.5 %) and DP (33.3 %).Conclusions: the dental plaque collection and the sample of stimulated whole saliva presented similar results in the S. mutans count. The most suitable method to detect the Lactobacillus spp. level in the oral cavity is the stimulated whole saliva method. (c) 2004 Elsevier Ltd. All rights reserved.