41 resultados para closed tray

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This in vitro study evaluated the dimensional accuracy of two impression techniques (tapered and splinted) with two stock trays (plastic and metal) for implant-supported prostheses. Materials and Methods: A master cast with four parallel abutment analogs and a passive framework were fabricated. Polyvinyl siloxane impression material was used for all impressions with two metal stock trays and two plastic stock trays (closed and open trays). Four groups (tapered plastic, splinted plastic, tapered metal, and splinted metal) and a control group (master cast) were tested (n = 5 for each group). After the framework was seated on each of the casts, one abutment screw was tightened, and the marginal gap between the abutment and framework on the other side was measured with a stereomicroscope. The measurements were analyzed with the Kruskal-Wallis one-way analysis of variance on ranks test followed by the Dunn method. Results: The mean values (+/- standard deviations) for the abutment/framework interface gaps were: master cast, 32 +/- 2 mu m; tapered metal, 44 +/- 10 mu m; splinted metal, 69 +/- 28 mu m; tapered plastic, 164 +/- 58 mu m; splinted plastic, 128 +/- 47 mu m. No significant difference was detected between the master cast, tapered metal, and splinted metal groups or between the tapered and splinted plastic groups. Conclusions: In this study, the rigidity of the metal stock tray ensured better results than the plastic stock tray for implant impressions with a high-viscosity impression material (putty). Statistically similar results were obtained using tapered impression copings and splinted squared impression copings. The tapered impression copings technique and splinted squared impression copings technique with a metal stock tray produced precise casts with no statistically significant difference in interface gaps compared to the master cast. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:544-550.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: This in vitro study compared the dimensional accuracy of stone index (I) and three impression techniques: tapered impression copings (T), squared impression copings (S) and modified squared impression copings (MS) for implant-supported prostheses. Methods: A master cast, with four parallel implant abutment analogs and a passive framework, were fabricated. Vinyl polysiloxane impression material was used for all impressions with two metal stock trays (open and closed tray). Four groups (I, T, S and MS) were tested (n = 5). A metallic framework was seated on each of the casts, one abutment screw was tightened, and the gap between the analog of implant and the framework was measured with a stereomicroscope. The groups' measurements (80 gap values) were analyzed using software (LeicaQWin - Leica Imaging Systems Ltd.) that received the images of a video camera coupled to a Leica stereomicroscope at 100× magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, 0.05. Results: The mean values of abutment/framework interface gaps were: Master Cast = 32 μm (SD 2); Group I = 45 μm (SD 3); Group T = 78 μm (SD 25); Group S = 134 μm (SD 30); Group MS = 143 μm (SD 27). No significant difference was detected among Index and Master Cast (P = .05). Conclusion: Under the limitations of this study, it could be suggested that a more accurate working cast is possible using tapered impression copings techniques and stone index. © 2013 Japan Prosthodontic Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste estudo, foram investigadas as densidades de carga adequadas para transporte de matrinxãs juvenis em sistema fechado com sacos plásticos. O transporte de 4h foi feito com peixes (23,5±0,4g; 11,6 (0,08cm) em jejum por 24h, em densidades de 83g L-1 (D1), 125g L-1 (D2), 168g L-1 (D3) e 206g L-1 (D4). Os peixes foram amostrados antes do transporte (AT), logo após o transporte (chegada) (DT) e 24h depois. A qualidade da água foi monitorada antes da captura dos peixes nos tanques de depuração, após o transporte nos sacos plásticos e nos tanques de recuperação. O oxigênio da água diminuiu para valores inferiores a 4mg L-1 em D2, D3 e D4, a temperatura esteve em torno de 32°C, pH 6,5-6,78, a amônia total foi de 1,09-1,7mg L-1, a amônia não-ionizada foi de 3,58-9,33 x 10³mg L-1 e alcalinidade 134-165mg CaCO3 L-1. O cortisol plasmático e a glicose sanguínea aumentaram após o transporte nos peixes em todas as densidades ensaiadas, voltando aos valores controle 24h depois. Os valores de osmolaridade não mudaram logo após o transporte, mas aumentaram 24h depois de modo igual em todas as densidades. O cloreto plasmático diminuiu na chegada, de modo inversamente proporcional à densidade de carga. O hematócrito diminuiu 24h depois da chegada dos peixes, em todas as densidades testadas, mas não houve diferença no número de eritrócitos. Não houve mortalidade até uma semana após o transporte. O matrinxã mostrou ser uma espécie tolerante a altas densidades de carga em embalagens para transporte além de suportar baixos níveis de oxigênio na água.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exact bounded solutions for a fermion subject to exponential scalar potential in 1 + 1 dimensions are found in closed form. We discuss the existence of zero modes which are related to the ultrarelativistic limit of the Dirac equation and are responsible for the induction of a fractional fermion number on the vacuum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem of a fermion subject to a general scalar potential in a two-dimensional world for nonzero eigenenergies is mapped into a Sturm-Liouville problem for the upper component of the Dirac spinor. In the specific circumstance of an exponential potential, we have an effective Morse potential which reveals itself as an essentially relativistic problem. Exact bound solutions are found in closed form for this problem. The behaviour of the upper and lower components of the Dirac spinor is discussed in detail, particularly the existence of zero modes. (c) 2005 Elsevier B.v. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this Letter a topological interpretation for the string thermal vacuum in the thermo field dynamics (TFD) approach is given. As a consequence, the relationship between the imaginary time and TFD formalisms is achieved when both are used to study closed strings at finite temperature. The TFD approach starts by duplicating the system's degrees of freedom, defining an auxiliary (tilde) string. In order to lead the system to finite temperature a Bogoliubov transformation is implemented. We show that the effect of this transformation is to glue together the string and the tilde string to obtain a torus. The thermal vacuum appears as the boundary state for this identification. Also, from the thermal state condition, a Kubo-Martin-Schwinger condition for the torus topology is derived. © 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The original Casimir effect results from the difference in the vacuum energies of the electromagnetic field, between that in a region of space with boundary conditions and that in the same region without boundary conditions. In this paper we develop the theory of a similar situation, involving a scalar field in spacetimes with closed spatial sections of negative curvature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We clarify and develop the results of a previous paper on the birth of a closed universe of negative spatial curvature and multiply connected topology. In particular we discuss the initial instanton and the second topology change in more detail, This is followed by a short discussion of the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed at evaluating the thermal performance of a modular ceiling system for poultry houses. The reduced- and distorted-scale prototypes used ceiling modules made of reforested wood and were covered with recycled long-life package tiles. The following parameters were measured for 21 days: tile internal surface temperature (ST), globe temperature and humidity index (WBGT), and radiant heat load (RHL). Measurements were made at times of highest heat load (11:00 am, 13:00 pm, and 03:00 pm). Collected data were analyzed by R statistics software. Means were compared by multiple comparison test (Tukey) and linear regression was performed, both at 5% significance level. The results showed that the prototype with the ceiling was more efficient to reduce internal tile surface temperature; however, this was not sufficient to provide a comfortable environment for broilers during the growout. Therefore, other techniques to provide proper cooling are required in addition to the ceiling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The free action for massless Ramond-Ramond fields is derived from closed superstring field theory using the techniques of Siegel and Zwiebach. For the uncompactified Type IIB superstring, this gives a manifestly Lorentz-covariant action for a self-dual five-form field strength. Upon compactification to four dimensions, the action depends on a U(1) field strength from 4D N = 2 supergravity. However, unlike the standard Maxwell action, this action is manifestly invariant under the electromagnetic duality transformation which rotates F-mn into epsilon(mnpq)F(pq).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We solve the spectrum of the closed Temperley-Lieb quantum spin chains using the coordinate Bethe ansatz. These models are invariant under the quantum group U-q[sl(2)].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with two aspects of relativistic cosmologies with closed spatial sections. These spacetimes are based on the theory of general relativity, and admit a foliation into space sections S(t), which are spacelike hypersurfaces satisfying the postulate of the closure of space: each S(t) is a three-dimensional closed Riemannian manifold. The topics discussed are: (i) a comparison, previously obtained, between Thurston geometries and Bianchi-Kantowski-Sachs metrics for such three-manifolds is here clarified and developed; and (ii) the implications of global inhomogeneity for locally homogeneous three-spaces of constant curvature are analyzed from an observational viewpoint.