143 resultados para aortic aneurysms

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introduction: So far the only endovascular option to treat patients with thoraco abdominal aortic aneurysms is the deployment of branched grafts. We describe a technique consisting of the deployment of standard off-the- shelf grafts to treat urgent cases.Material and Methods: The sandwich technique consists of the deployment of ViaBahn chimney grafts in combination with standard thoracic and abdominal aortic stent grafts. The chimney grafts are deployed using a transbrachial and transaxillary access. These coaxial grafts are placed inside the thoracic tube graft. After deployment of the infrarenal bifurcated abdominal graft a bridging stent-a short tube graft is positioned inside the thoracic graft further stabilizing the chimney grafts.Results: 5 patients with symptomatic thoraco abdominal aneurysms were treated. There was one Type I endoleak that resolved after 2 months. In all patients 3 stentgrafts had to be used When possible all visceral and renal branches were revascularized. A total number of 17 arteries were reconnected with covered branches. During follow up we lost one target vessel the right renal artery.Conclusion: The sandwich technique in combination with chimney grafts permits a total endovascular exclusion of thoraco abdominal aortic aneurysms. In all cases off-the shelf products and grafts could be used. The number of patients treated so far is still too small to draw further more robust conclusions with regard to long term performance and durability. (C) 2010 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Open surgical repair of complex abdominal aortic aneurysms requires more extensive dissection and aortic clamping above the renal or mesenteric arteries. Although results of open surgical series have shown variation, morbidity and mortality is higher compared with infrarenal aortic aneurysm repair. Potential complications include renal insufficiency, mesenteric ischemia, multisystem organ failure, and death. Although endovascular treatment with fenestrated and branched endografts might potentially decrease the risk of complications and mortality, its role is not yet defined and the technology is not widely available. Issues related to durability of the procedure and secondary interventions might limit its application to patients with higher risk or those with hostile anatomy. This article summarizes the clinical results of open surgical repair of pararenal abdominal aortic aneurysms to provide a benchmark for comparison with results of endovascular treatment, using fenestrated and branched techniques. © Annals of Vascular Surgery Inc.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: The sandwich technique is an endovascular off-the-shelf solution for patients with thoracoabdominal aortic aneurysms (TAAAs). In a sandwich configuration, the chimney stent runs in the middle of a space created by two or three aortic endografts.Methods: All patients with TAAAs who were treated with the sandwich technique were included in the study. Self-expanding Viabahn grafts (W. L. Gore and Associates Inc, Flagstaff, Ariz) were used as parallel grafts in the renal arteries and visceral vessels. Caudad-facing chimney grafts were used for the visceral arteries and cephalad-facing periscope grafts for the renal arteries.Results: During the study period, 32 patients with TAAAs were treated with sandwich grafts. Indication for the procedure in 43% was an acute onset of symptoms, including two patients with a rupture and a retroperitoneal hematoma. Three patients required an additional debranching procedure. A total of 104 chimney grafts were implanted. Two patients died postoperatively because of the operation. Major adverse events were recorded in five patients, including one patient with persistent paraplegia and two with permanent renal failure requiring dialysis. The incidence of chimney graft occlusion was higher in patients with three or four parallel grafts than in those with two chimney grafts only. Patients with chronic dissections had a 12-times higher incidence of chimney graft occlusion than aneurysm patients. The number of patients with type I or III endoleaks was higher in the group with three or four parallel grafts.Conclusions: The sandwich technique is an off-the-shelf endovascular alternative to treat patients with TAAAs in an emergent setting. The combination of chimney grafts with a periscope configuration enables a rapid endovascular aneurysm exclusion with acceptable midterm results.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Giant aortic aneurysms (transverse diameter greater than 10.0 cm) are rare and open surgery is often the treatment of choice. We report an infrarenal saccular giant aortic aneurysm (measuring 25 cm in transverse diameter), which was treated with endovascular repair, with immediate technical success. No similar report of a giant infrarenal aortic aneurysm treated with an endovascular technique was found in the literature. High-risk patients could possibly benefit from the endovascular technique. Nevertheless, patient survival remains strongly influenced by comorbidities.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Endovascular aneurysm repair (EVAR) is already considered the first choice treatment for abdominal aortic aneurysms (AAA). Several different strategies have been used to address limitations to arterial access caused by unfavorable iliac artery anatomy. The aim of this report is to illustrate the advantages and limitations of each option and present the results of using the internal endoconduit technique and the difficulties involved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

CONTEXTO: A cirurgia videolaparoscópica (CVL) vem evoluindo como alternativa cirúrgica menos invasiva para o tratamento da doença aterosclerótica oclusiva aorto-ilíaca e do aneurisma da aorta abdominal. Poucos estudos avaliaram objetivamente a curva de aprendizado com essa técnica em cirurgia vascular. OBJETIVO: Avaliar objetivamente os tempos e a evolução de cada passo cirúrgico e demonstrar a exeqüibilidade dessa técnica. MÉTODOS: Entre outubro 2007 e janeiro de 2008, dois cirurgiões vasculares iniciantes na CVL operaram, após cursos e treinamentos, seis porcos consecutivos, com dissecção aórtica e interposição de um enxerto de dácron em um segmento da aorta infra-renal abdominal, com técnica totalmente laparoscópica. RESULTADOS: Todos os tempos cirúrgicos foram decrescentes ao longo do estudo, apresentando redução de 45,9% no tempo total de cirurgia, 85,8% no tempo de dissecção da aorta, 81,2% na exposição da aorta, 55,1% no clampeamento total, 71% na confecção da anastomose proximal e 64,9% na anastomose distal. CONCLUSÃO: O presente estudo mostrou que os resultados técnicos satisfatórios da CVL vascular ocorreram somente após longa curva de aprendizado, que foi decrescente ao longo do tempo, à medida que aumentou a experiência e vivência com os materiais e com a visão não-estereoscópica. Essa técnica pode ser realizada com perfeição por cirurgiões vasculares desde que façam cursos especializados, com treinamento em simuladores e animais, e desde que busquem constante aprimoramento a fim de conseguir resultados similares aos obtidos com a cirurgia convencional.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In ascending aorta aneurysms, there is an enlargement of the whole vessel, whereas aortic dissections (ADs) are characterized by the cleavage of the wall into 2 sheets at the external half. We searched if alterations in collagen could be related to these diseases. Sections of aortas from 14 case patients with acute dissections, 10 case patients with aneurysms, and 9 control subjects were stained with picrosirius. Slides were analyzed under polarized microscopy to evaluate the structure of collagen fibers. The proportion of collagen was calculated in each half of the medial layer by color detection in a computerized image analysis system. Collagen appearance under polarized light was consistent with collagenolysis. The mean collagen proportions at the inner and outer halves, respectively, were 0.50 +/- 0.13 and 0.40 +/- 0.08 in the control group, 0.20 +/- 0.10 and 0.18 +/- 0.12 in the AD group, and 0.33 +/- 0.12 and 0.19 +/- 0.12 in the aneurysm group. The AD (P < .01) and control (P = .04) groups had less collagen at the external half, no difference was found in the aneurysm group (P = .71). In both halves, there was less collagen in the case patients than in the control subjects (all P < .01), but at the internal half, the decrease was significantly greater in the case patients with aneurysms than in those with dissections (P = .03; at the external half, P = .99). Aortic dissections and aneurysms show a decrease in collagen content that could be related to a weakness of the wall underlying the diseases, but the locations of the decrease differ: in dissections, it is situated mostly at the external portion of the media (site of cleavage), whereas in aneurysms, it is more diffuse, consistent with the global enlargement. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We herein report a case of a double aortic arch in a 10-week-old male dog of no defined race, which presented episodes of regurgitation at the time of weaning. This vascular malformation was Characterized by the persistence of two aortic arches, right and left, of varying dimensions. The right aortic arch was observed to be larger. During post mortem examination the vessels of the animal were injected with coloured latex bi-centrifuged CIS 1-4 polisopreno which revealed the patency of the two aortic arches. Concomitantly, dilation of the cranial oesophagus causing constriction was observed, indicating megaesophagus, Apart from the constriction, the oesophagus presented normal morphometric parameters in relation to its dimensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some properties of the volatile anesthetics, such as vasodilatation and myocardial depression, combined with the sympathetic inhibition that alpha 2-agonists can produce may determine hemodynamic alterations during aortic, surgery. The interaction between dexmedetomidine (DEX), an alpha 2-agonist, and sevoflurane during aortic surgery is unknown. We studied the effects of DEX on hemodynamics and systemic oxygenation during aortic cross-clamping (Aox) and unclamping (UAox) in sevoflurane-anesthetized dogs Twenty dogs were. anesthetized with sevoflurane and were randomly assigned to two groups prior to Aox and UAox: control, n = 10, received saline infusion only, and DEX (1 mu g.kg(-1) load followed by 1 mu g.kg(-1).h(-1) infusion), n = 10. Hemodynamic and oxygenation variables were measured at baseline, after saline or DEX loading dose, 20 and 40 min after Aox, and 20 and 40 min after UAox. After DEX administration, heart rate, cardiac index l and systemic oxygen transport index (131021) were lower than in control group. Aox increased mean arterial pressure (MAP) and systemic vascular resistance index (SVRI) in both groups, but the effects were greater with DEX. Cl, heart rate, and DO(2)I were lower, while central venous pressure (CVP) and pulmonary artery occlusion pressure were higher in DEX compared to control. After UAox, MAP, CVP and SVRI were maintained higher in DEX in relation to control. We conclude that in sevoflurane-anesthetized dogs DEX alters the cardiovascular response during aortic surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Significant morbidity and mortality are related to conventional aortic replacement surgery. Endovascular debranching techniques, fenestrated or branched endografts are time consuming and costly.Objective: We alternatively propose to use endovascular approach with parallel grafts for debranching of aortic arch.Methods: Under general anesthesia, 12 F sheaths were inserted in the femoral, axillary and common carotid arteries for vascular accesses. ViaBahn grafts 10 - 15 cm in length were placed into the aortic arch from right common carotid, left common carotid and left axillary arteries, until the tip of each graft reached into the ascending aorta. Through one femoral artery, the aortic stent-graft was positioned and delivered. Soon after, the parallel grafts were sequentially delivered. Self-spanding Wallstents(R) were used for parallel grafts reinforcement. Ballooning was routinely used for parallel grafts and rarely for aortic graft.Results: This technique was used in 2 cases. The first one was a lady with 72 years old, with an aortic retrograde dissection from left subclavian artery and involving remaining arch branches. Through right common carotid artery a stent-graft was placed in the ascending aorta and through the left common carotid artery a ViaBahn was inserted parallel to the former. A thoracic endograft then covered all the aortic arch dissection extending into the ascending aorta close to the sinu-tubular junction. The second case was a 82 year old male patient with a 7 cm aortic arch aneurysm. Through both common carotid arteries ViaBahn grafts were introduced and positioned into the ascending aorta. Soon after, the deployment of the thoracic stent graft covered all parallel grafts of the aortic arch, excluding the aneurysm. Both cases did not have neurologic or cardiac complications and were discharged 10 days after the procedure.Conclusions: This technique may be a good minimal invasive off-the-shelf technical option for aortic arch "debranching". More data and further improvements are required before this promising technique can be widely advocated. (C) 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perforation of inferior vena cava (IVC) by filter struts ranges from 9% to 24%, and clinical sequelae and complications are unpredictable. The aim of this article was to report an unusual case of late complication of IVC filter that caused an IVC wall perforation and penetration of the filter's hooks in the aorta, which was treated by endovascular procedure. Molding strut tip by balloon angioplasty, its accommodation with a bare stent, and its coverage and protection with an endoprosthesis is probably the first technique reported so far in this situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To analyze the potential contribution of contractility state and ventricular geometry to the development of heart failure in rats with aortic stenosis.Methods: Rats were divided into three groups: compensated aortic stenosis (AS, n = 11), heart failure AS (n = 12) and control rats (C, n = 13).Results: After 21 weeks, failing AS rats presented higher systolic (C = 36.6 +/- 3.1, AS-78.6 +/- 4.8*, failing AS = 104.6 +/- 7.8*) and diastolic meridian stress (C = 6.9 +/- 0.4, AS = 20.1 +/- 1.1*, failing AS = 43.2 +/- 3.2*(dagger)), hydroxyproline (C = 3.6 +/- 0.7 mg/g, AS = 6.6 +/- 0.6* mg/g, failing AS = 9.2 +/- 1.4*(dagger) mg/g) and cross-sectional area (C = 338 +/- 25 mu m(2), AS = 451 +/- 32* mu m(2), failing AS = 508 +/- 36*(dagger) mu m(2)), in comparison with control and compensated AS animals (*p < 0.05 vs. control, (dagger)p < 0.05 vs. AS). In the isometric contraction study, considering the time from peak tension to 50% relaxation (RT50), the relative variation responses, following post-rest contraction and increase in Ca2+ concentration, were higher in failing AS than compensated AS animals. In contrast, following post-rest contraction, compensated AS group presented higher values of the peak developed tension (DT) than failing AS group. Following beta-adrenergic stimulation, control animals presented higher values of +dT/dt and -dT/dt than AS animals. In addition, failing AS animals presented higher TPT values than compensated AS animals.Conclusion: Myocardial contractile dysfunction contributes to the development of heart failure in rats with aortic stenosis. (c) 2006 Elsevier B.V.. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)