10 resultados para activity coefficient
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The molar single ion activity coefficient (y(F)) of fluoride ions was determined at 25 degrees C and ionic strengths between 0.100 and 3.00 mol L(-1) NaClO(4) using an ion-selective electrode. The activity coefficient dependency on ionic strength was determined to be Phi(F) = log y(F) = 0.2315I-0.041I(2). The function Phi(F)(I), combined with functions obtained in previous work for copper (Phi(Cu)) and hydrogen (Phi(H)), allowed us to make the estimation of the stoichiometric and thermodynamic protonation constants of some halides and pseudo-halides as well as the formation constants of some pseudo-halides and fluoride 1:1 bivalent cation complexes. The calculation procedure proposed in this paper is consistent with critically-selected experimental data. It was demonstrated that it is possible to use Phi(F)(I) for predicting the thermodynamic equilibrium parameters independently of Pearson's hardness of acids and bases.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A, M. Soares, V, M, Rodrigues, M. I. Homsi-Brandeburgo, M. H. Toyama, F, R, Lombardi, K. Arni and J. R, Giglio. A rapid procedure for the isolation of the Lys-49 myotoxin II from Bothrops moojeni (caissaca) venom: Biochemical characterization, crystallization, myotoxic and edematogenic activity. Toxicon 36, 503-514, 1998.-Bothrops moojeni snake venom was fractionated on a CM-Sepharose column which was previously equilibrated with 0.05 M ammonium bicarbonate buffer at pH 8.0 and subsequently eluted with an ammonium bicarbonate concentration gradient from 0.05 to 0.5 M at constant pH (8.0) and temperature (25 degrees C). The fraction which eluted last (M-VI) showed, after direct lyophilization, a single band by polyacrylamide gel electrophoresis (PAGE) and SDS-PAGE, indicating an approximate M,. of 14 000 and 77 000, in the presence and absence of dithiothreitol, respectively. Its amino acid composition revealed a high level of hydrophobic and basic amino acids as well as 13 half-cystine residues. Its isoelectric point and extinction coefficient (E-1.0cm(1.0mg/ml) at 278 nm and pH 7.0) were 8.2 and 1.170, respectively. M-VI was devoid of phospholipase A(2) (PLA(2)) activity on egg yolk, as well as of hemorrhagic, anticoagulant and coagulant activities, but could induce drastic necrosis on skeletal muscle fibres as well as rapid and transient edema on the rat paw. Its N-terminal sequence: SLFELGKMILQETGKNPAKSYGVYGCNCGVGGRGKPKDATDRCCYVHKCCYK.... revealed high homology with other Lys 49 PLA(2)-like myotoxins from other bothropic venoms. Orthorhombic crystals of M-VI? which diffracted to a maximal resolution of 1.6 Angstrom. were obtained and indicated the presence of a dimer in the asymmetrical unit. (C) 1998 Elsevier B.V. Ltd. All rights reserved.
Resumo:
1. In order to investigate the effect of aging on the erythrocyte glutathione system, total glutathione (GSH), glutathione reductase (GSH-red) and glutathione peroxidase (GSH-px) levels were measured in erythrocytes from 33 young (mean age = 30.5 +/- 9.7 years) and 28 aged (mean age = 68.9 +/- 11.4 years) healthy individuals.2. GSH was 3.5 +/- 1.8-mu-M/g Hb for the young group, a value significantly greater (P < 0.01) than 2.3 +/- 0.9-mu-M/g Hb found for the aged group. Similarly, GSH-red activity, 5.5 +/- 1.8 IU/g Hb, was higher (P < 0.05) for the young group than 3.4 +/- 0.9 IU/g Hb found for the aged group. The GSH-px activity levels for the young group, 21.1 +/- 5.9 IU/g Hb, were significantly greater (P < 0.01) than 12.0 +/- 3.3 IU/g Hb for the aged group. The lower activity detected in the aged group for all of these parameters of the glutathione redox system was not related to low levels of hematocrit or hemoglobin.3. There was no statistical difference in the activation coefficient (AC) of reductase (+FAD/-FAD) between groups, which seems to indicate that the lower activity of glutathione reductase observed in the aged group was not due to riboflavin deficiency.4. Additional information is required to determine the mechanisms controlling the glutathione redox system and its role in the aging process.
Resumo:
Purpose. Isokinetic tests are often applied to assess muscular strength and EMG activity, however the specific ranges of motion used in testing (fully flexed or extended positions) might be constrictive and/or be painful for patients with injuries or under-going rehabilitation. The aim of this study was to examine the effects of different ranges of motion (RoM) when determining maximal EMG during isokinetic knee flexion and extension with different types of contractions and velocities. Methods. Eighteen males had EMG activity recorded on the vastus lateralis, vastus medialis, semitendinosus and biceps femoris muscles during five maximal isokinetic concentric and eccentric contractions for the knee flexors and extensors at 60° • s -1 and 180° • s -1. The root mean square of EMG was calculated at three different ranges of motion: (1) a full range of motion (90°-20° [0° = full knee extension]); (2) a range of motion of 20° (between 60°-80° and 40°-60° for knee extension and flexion, respectively) and (3) at a 10° interval around the angle where peak torque is produced. EMG measurements were statistically analyzed (ANOVA) to test for the range of motion, contraction velocity and contraction speed effects. Coefficients of variation and Pearson's correlation coefficients were also calculated among the ranges of motion. Results. Predominantly similar (p > 0.05) and well-correlated EMG results (r > 0.7, p ≤ 0.001) were found among the ranges of motion. However, a lower coefficient of variation was found for the full range of motion, while the 10° interval around peak torque at 180° • s -1 had the highest coefficient, regardless of the type of contraction. Conclusions. Shorter ranges of motion at around the peak torque angle provides a reliable indicator when recording EMG activity during maximal isokinetic parameters. It may provide a safer alternative when testing patients with injuries or undergoing rehabilitation.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Although measurement errors can impair statistical analysis, reliability analysis has been neglected in applied microbiology. This study assessed the intra-rater reproducibility of the Agar-based method for estimation of phospholipase activity (Pz). Pz readings were performed twice by two examiners (E1, E2), either directly on plates or in photos, and both black and white backgrounds were used. Pz values were taken from one or triplicate colonies from each sample (n=30). Intra-examiner reproducibility was estimated using Intraclass Correlation Coefficient (ICC). For both examiners, reading triplicate (ICCE1=0.91, ICCE2=0.86) was better than one colony (ICCE1=0.86, ICCE2=0.80). E1 had an excellent concordance when measurements were performed on photos using a white background (ICC=0.95) and a good concordance in the other conditions
Resumo:
SUMMARY. A new method was developed to evaluate the total antioxidant activity in plant extracts, which was based on radical scavenging using 2,2’-azinobis-(3-ethylbenzothiazoline)-6-sulfonic acid. The proposed method was linear in the range of 0.86 to 26.0 μg/mL, displaying a correlation coefficient of 0.999. Moreover, the accuracy and precision analysis showed agreement with ANVISA guidelines (96.66 to 98.46 % and < 5.0%, respectively). The method demonstrated sensitivity, robustness and efficiency in detecting low concentrations of plant extracts (detection and quantification limit of 0.86 and 2.87 μg/mL, respectively) that may be present in pharmaceuticals and cosmetics preparations, again in agreement with ANVISA. In addition, the assay is inexpensive and easy to perform.