129 resultados para Vestimenta de proteção radiológica
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
After the discovery of ionizing radiation, its applications in various fields of science began to take significant proportions. In the case of medicine, there are the application areas in radiotherapy, diagnostic radiology and nuclear medicine. It was then necessary to create the field of radiological protection to establish the conditions necessary for the safe use of such ionizing radiation. Apply knowledge obtained during the graduation stage and in the practice of radiological protection in the areas of nuclear medicine and diagnostic radiology. In the area of nuclear medicine, tests were made in the Geiger-Muller counters (GM) and the dose calibrator (curiometer), the monitoring tests of radiation, waste management, clean of the Therapeutic room and testing the quality control of gamma-chambers. In the area of radiology, were performed tests of quality control equipment for conventional X-ray equipment and x-ray fluoroscopy, all following the rules of the National Health Surveillance Agency (ANVISA), and reporting of tests. The routine developed in the fields of nuclear medicine in hospitals has proved very useful, since the quality control of GM counters contribute to the values of possible contamination are more reliable. The control of dose calibrator enables the patient not to receive different doses of the recommended amounts, which prevents the repetition of tests and unnecessary exposure to radiation. The management of waste following the rules and laws established and required for its management. Tests for quality control of gamma chambers help to evaluate its medical performance through image. In part of diagnostic radiology, tests for quality control are performed in order to verify that the equipment is acceptable for usage or if repairs are needed. The knowledge acquired at the internship consolidated the learning of graduation course
Resumo:
O uso de radiações ionizantes (R.I.), nas mais variadas atividades tem aumentado nas últimas décadas. Com o avanço tecnológico, novos e sofisticados equipamentos emissores de R.I. tem surgido no cenário nacional, o que torna imperativo a difusão do conhecimento sobre os conceitos de proteção radiológica junto à comunidade em geral, e neste sentido, o curso de física médica desenvolve um importante papel, quer seja no aspecto informativo quanto formativo de cidadãos e profissionais críticos e politicamente corretos, que possam contribuir com as Políticas Públicos dos órgãos normatizadores e fiscalizadores das atividades de vigilância sanitária. Conforme a legislação atual (Resolução SS-625 de 14/12/1994, da Secretaria de Estado da Saúde, e Portaria 453 de 01/06/1998 da Vigilância Sanitária do Ministério da Saúde), todos os serviços que utilizam radiações ionizantes devem realizar testes de avaliação dos parâmetros radiométricos dos equipamentos emissores de R.I., sendo exigidos as medidas de Levantamento Radiométrico das instalações, o Teste de Radiação de Fuga do cabeçote emissor e a implementação de Programa de Garantia de Qualidade dos equipamentos e dos procedimentos radiológicos. Este procedimento tem como objetivo principal a obtenção de imagens radiográficas com qualidade e a segurança de pacientes e profissionais, evitando a exposição desnecessária à radiação de pacientes e profissionais. A correta realização de procedimentos radiológicos além de reduzir a dose nos pacientes também promove significativa diminuição nos custos, por não haver necessidade da repetição dos exames. No Brasil, conforme dados da Secretaria de Atenção à Saúde SAS/MS, atualmente existem instalados 4.469 mamógrafos, 25.930 aparelhos de raios-x médicos, 39.438 aparelhos de raios-x odontológicos e...(Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
The Nuclear Medicine is a medical specialty which uses different radioisotopes for diagnostic and therapeutic purposes. The isotopes are radioactive elements which are administered in vivo and present distribution to specific organs or cell types. The knowledge of radioactivity and notions related to ionizing radiation allow to contextualize the radiological protection measures to be taken in Nuclear Medicine. So it is possible to minimize unnecessary exposure to patients, the public, and individuals occupationally exposed and the environmental. For this it is necessary to relate the physical and technological bases apply to this mode with the standards established by regulatory agencies, including the CNEN (National Nuclear Energy Commission) and ANVISA (National Agency for Sanitary Vigilance). In this scenario, it is important that the theoretical endorse the activities which are periodically audited for verification of compliance with the standards that aim to radioprotection. One role of the Medical Physicist in these services is, therefore, act as Radiation Protection Supervisor exerting numerous activities and ensuring compliance with these standards. In this context the stage in the area of Nuclear Medicine was developed in many customers of the enterprise Rad Dimenstein & Associados LTDA, among them the hospitals Israelita Albert Einstein (HIAE), Nossa Senhora de Lourdes (HNSL), Santa Paula (HSP), Cruz Azul (CRAZ), Grupo Fleury, among other clinics. Following the routine and then carrying out various activities pertaining to the Medical Physicist in the area, it was noted that the measures and actions are extremely effective and fundamental in terms of radiological protection
Resumo:
Ionizing radiation is used nowadays in various sectors such as agriculture, industry and medicine. The main specialties of medicine which use radiation are the diagnostic radiology, nuclear medicine and radiotherapy. Radiotherapy is a therapeutic modality that is a well established feature for the treatment of malignant disease or not. However, the inadvertent use of ionizing radiation can produce deleterious effects that result in sequels that compromise the welfare of the people involved. The analysis of radiological protection emphasizes the importance of avoiding inappropriate exhibitions aimed at protecting the health of patients, the professionals involved and the general public. The basic principles of radioprotection are justification, optimization and restriction for individual dosage. The departments of radiotherapy are regulated in accordance with specific technical standards of the National Commission of Nuclear Energy (CNEN), which during the inspection for issue and renewal of the authorization of operation requires the submission of a radioprotection plan, this document that requires great demand of time, and has generated much debate among professionals in medical physics, given the difficulties encountered in their preparation. After examining the radioprotection plan of some radiotherapy services, as suggested in order to guide those responsible for drawing up these plans, especially beginners in the career of the physics of radiation, this paper presents a model plan that is in line radioprotection it requires the Technical Standards of CNEN and can easily be the reality of appropriate services
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
This study aims to determine surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence dosimetry. Twenty seven exams from different dogs were performed at the Faculdade de Medicina Veterinária e Zootecnia da Universidade Estadual Paulista (FMVZ-UNESP/Botucatu). The doses were evaluated using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN). The pulmonary metastasis exams are carried out in three projections, one dorsal-ventral and two lateral-lateral. During the procedures the projection thicknesses and source-skin surface distances were registered. To simulate the dog phantom the dosimeters were positioned in a cubic simulator (30x30x30 cm) of polymethylmethacrylate (PMMA) filled with water and irradiated according to the parameters of projections with the X-ray energies ranging from 45 to 70 kV. To estimate the surface skin dose the dose-response curves were obtained for X-ray energies of 50 and 70 kV using the diagnostic X-ray beam machine of the Instruments Calibration Laboratory of IPEN for doses of 1.5, 2.0, 2.5, 3.5 and 4.0 mGy. The main difficulty of this work was the dog immobilization that is reflected in poor-quality diagnostic imaging and, consequently, demands the repetition of the exams, which contributes to the increase of the doses received by the animals being studied and the clinical staff. The doses evaluated in this type of procedure are between 0.43 and 4.22 mGy. This research has shown to be extremely important for the assessment of doses involved in veterinary diagnostic radiology procedures, and as a parameter in the individual monitoring of pet’s owners who assist the animal positioning and occupationally exposed workers of the Department of Veterinary Radiology
Resumo:
This work presents a brief historical about the use of ionizing radiations in Veterinary Medicine, instructing the physical beginnings and techniques wrapped in the realization of the proceedings of radiotherapy in animals, illustrating some treated cases, highlighting the difficulties and pointing to the perspectives and importance of the acting of the medical physics in this kind of therapeutic still little used in the national scenery.
Resumo:
Pós-graduação em Design - FAAC
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Perdas significativas ocorrem durante o armazenamento e a comercialização de uvas de mesa devido, principalmente, à ocorrência do mofo cinzento (Botrytis cinerea Pers.:Fr.) e, para o controle de patógenos emprega-se, geralmente, o dióxido de enxofre (SO2). Diante da restrição crescente ao uso de produtos químicos em pós-colheita, tem ocorrido considerável interesse em métodos alternativos de controle. Este trabalho teve como principal objetivo avaliar os efeitos da quitosana, na proteção pós-colheita de uva 'Itália' contra B. cinerea. In vivo, avaliou-se o efeito direto e indireto da quitosana pelo tratamento dos cachos de uva, antes e após a inoculação com o patógeno. Utilizou-se quitosana nas concentrações de 0,00; 0,25; 0,50; 1,00; 1,50 e 2,00 % (v/v). Para inoculação, em 10 bagas de cada cacho de uva foram feitos ferimentos de ±2 mm de profundidade, procedendo-se em seguida, a aspersão da suspensão de conídios (±10(5) conídios.mL-1) de B. cinerea. Após os tratamentos, os cachos foram mantidos a 25±1 °C / 80-90 % UR e avaliados diariamente quanto à incidência e severidade da podridão. Avaliações in vitro do efeito do produto sobre o patógeno também foram realizadas analisando-se o crescimento micelial e a germinação dos conídios de B. cinerea. A solução de quitosana, nas concentrações de 1,5 e 2,0 % (v/v), quando empregada após a inoculação com B cinerea, reduziu significativamente o índice de doença no entanto, quando os cachos foram tratados antes da inoculação, não houve efeito significativo do tratamento sobre o desenvolvimento da doença. Nos ensaios in vitro, a solução de quitosana, nas maiores concentrações, suprimiu o crescimento micelial do patógeno e retardou a germinação dos conídios.
Resumo:
OBJETIVO: Atualmente, entre as mulheres, a relação sexual é a forma de transmissão que mais tem contribuído para a feminização da epidemia de HIV/Aids. Na busca constante de se estabelecer padrões mais adequados de orientação para saúde, investigou-se o uso de medidas contraceptivas, que também sirvam de proteção da transmissão do HIV, entre mulheres portadoras de HIV/Aids. MÉTODOS: Estudo exploratório desenvolvido em um serviço público ambulatorial de um hospital universitário, referência aos portadores de HIV/Aids da região centro-sul do Estado de São Paulo, no período de cinco meses (2000 a 2001). Foram estudadas 73 mulheres portadoras da infecção pelo HIV, ou com Aids. Os dados foram obtidos por meio de um formulário que investigava a caracterização sociodemográfica, as formas de anticoncepção utilizada e a situação sorológica do parceiro sexual. Os dados foram analisados descritivamente e os conteúdos das respostas abertas, agrupados em temas. Foi aplicado o teste exato de Fisher para análise de algumas variáveis, em nível de 5%. Para a análise de conteúdo utilizou-se a proposta de Bardin. RESULTADOS: A maioria das mulheres estava em fase de vida reprodutiva, eram casadas e foram contaminadas quase exclusivamente por meio da relação heterossexual. Entre elas, 35,4% referiam parceiro sexual discordante quanto à sorologia anti-HIV, e 13,7% utilizavam formas inadequadas de anticoncepção que também não protegiam da transmissão do HIV. CONCLUSÕES: Os resultados alertam para a necessidade de ações educativas continuadas quanto a experiências sexuais mais seguras entre portadoras de HIV/Aids, para que elas possam discutir com seus parceiros outras formas de exercerem sua sexualidade, sendo capazes de estabelecer opção contraceptiva mais consciente, de maneira a zelar pela sua saúde, do parceiro e até do concepto.
Resumo:
Estudo de natureza quantitativa descritiva em um Hospital Universitário do Estado de São Paulo, teve como objetivo avaliar a promoção, proteção e apoio ao aleitamento materno através da verificação do cumprimento dos dez passos para o sucesso do aleitamento de acordo com a iniciativa Hospital Amigo da Criança, proposta pelo Ministério da Saúde. A avaliação revela práticas facilitadoras da amamentação, no entanto, faz-se necessário algumas mudanças nas rotinas hospitalares para a efetivação dos dez passos. em média, 79% das respostas foram afirmativas para o cumprimento dos passos, o que está próximo aos 80% preconizado. No entanto, se analisarmos as respostas para cada passo, identificamos pontos para serem melhorados. Chamou-nos a atenção o fato de que a prática de colocar o recém-nascido junto à mãe logo após o nascimento, permitindo a amamentação na primeira meia hora, foi relatada por 100% das mães entrevistadas que tiveram parto normal e por 80% daquelas que tiveram parto cesárea. Investimentos e mudanças em direção ao cumprimento dos dez passos contribuirão para um melhor atendimento à população e para a formação de profissionais amigos da criança.
Resumo:
Os objetivos do trabalho foram: quantificar as exposições dérmicas e respiratórias potenciais proporcionadas ao tratorista em pulverizações de agrotóxicos, na cultura de goiaba, com o turbopulverizador; avaliar a eficiência de duas vestimentas de proteção individual; avaliar a segurança e classificar estas condições de trabalho em seguras ou inseguras para cada agrotóxico considerado. A exposição dérmica potencial proporcionada ao tratorista pela condição de trabalho foi de 3.807,3 mL de calda/7h. A eficiência do conjunto de proteção individual Agro Light foi de 96,7 %, e a do Azeredo, 96,2 %. A exposição dérmica potencial nas regiões do corpo mais expostas do tratorista à pulverização, em ordem decrescente, foram os pés, os braços, as coxas+pernas-frente e o tronco-atrás. A exposição dérmica não-controlada pelos conjuntos de proteção individual foi igualmente distribuída em todas as regiões do corpo do tratorista devido aos controles das exposições dérmicas que proporcionaram às regiões mais expostas do corpo. Foram classificadas como seguras as pulverizações de três dos 17 agrotóxicos considerados e sete com o uso das vestimentas de proteção individual. As demais foram classificadas como inseguras.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)