10 resultados para Upper semi-continuity

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we prove a stability result about the asymptotic dynamics of a perturbed nonautonomous evolution equation in ℝn governed by a maximal monotone operator. Copyright © 2013 John Wiley & Sons, Ltd. Copyright © 2013 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

For eta >= 0, we consider a family of damped wave equations u(u) + eta Lambda 1/2u(t) + au(t) + Lambda u = f(u), t > 0, x is an element of Omega subset of R-N, where -Lambda denotes the Laplacian with zero Dirichlet boundary condition in L-2(Omega). For a dissipative nonlinearity f satisfying a suitable growth restrictions these equations define on the phase space H-0(1)(Omega) x L-2(Omega) semigroups {T-eta(t) : t >= 0} which have global attractors A(eta) eta >= 0. We show that the family {A(eta)}(eta >= 0), behaves upper and lower semi-continuously as the parameter eta tends to 0(+).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

defect metal alloy strip when thixorolling directly from the semi-solid state. To facilitate the study lead/tin alloys were chosen for their relatively low operating temperature. The objective is to extrapolate these findings to the higher temperature aluminium, alloys. Three alloys (70%Pb30%Sn, 60%Pb-40%Sn, 50%Pb-50%wtSn) were used particularly to study the influence of the solidification interval. The equipment consists of a two roll mill arranged as an upper and lower roller, where both rollers are driven at a controlled speed. The lower roller is fed with semi solid alloy through a ceramic nozzle attached to the lower end of a cooling slope. Several types of nozzle and their position at the roller were tested. This produced different solidifications and consequently different finished strip. The alloys were first cast and then poured onto the cooling slope through a tundish in order to create a continuous laminar flow of slurry and uniformity of metal strip quality. The pouring was tested at different positions along the slope. The cooling slope was coated with colloidal graphite to promote a smooth slurry flow and avoid the problem of adherence and premature solidification. The metallic slurry not only cools along the slope but is also initially super-cooled to a mush by the lower roller whilst at room temperatures, thus enabling thixorolling. It was also found that the nozzle position could be adjusted to enable the upper roller to also contribute to the solidification of the metallic slurry. However the rollers and the cooling slope naturally heat up. Temperature distribution in these zones was analysed by means of three thermocouples positioned along the cooling slope and a fourth in the base of the semi solid pool within the nozzle. The objective being to design an optimum pouring and cooling system. The formed strip was cooled down to room temperature with a shower of water. Microstructures of the thixorolling process were analysed. The differences in solidification conditions resulted in differing qualities of finished strip and corresponding defect types, all of which are a serious quality issue for the rolled product.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work we obtain some continuity properties on the parameter p at p = 2 for the Takeuchi-Yamada problem which is a degenerate p-Laplacian version of the Chafee-Infante problem. We prove the continuity of the flows and the equilibrium sets, and the upper semicontinuity of the global attractors. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The operational details of the apparent electrical conductivity (ECa) sensor manufactured by Veris Technologies have been extensively documented in literature reports, but the geographical distribution of these research studies indicate a strong regional concentration in the US Mid-west and Southern states. The agricultural lands of these states diverge significantly to the soil conditions and water regime of irrigated land in the US South-western states such as Arizona where there is no previous research reports of the use of this particular sensor. The objectives of the present study were to analyze the performance of this sensor under the conditions of typical soils in irrigated farms of Central Arizona. We tested under static conditions the performance of the sensor on three soils of contrasting texture. Observations were collected as time series data as soil moisture changed from saturation to permanent wilting point. Observations were repeated at the hours of lowest and highest temperatures. In addition, this study included soil penetration resistance and salinity determinations. Preliminary results indicate that soil temperature of the upper layer caused the most dynamic change in the sensor output. The ECa curves of the three soil textures tested had well defined distinctive characteristics. Final multivariate analysis is pending.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To describe the preoperative upper limb lymphoscintigraphic pattern in women with breast cancer. Methods: Thirty-seven patients undergoing lymphoscintigraphy within 30 days of surgery were investigated. Lymphoscintigraphic studies of 37 upper limbs ipsilateral to surgery and 32 contralateral upper limbs were performed. The examination protocol consisted in obtaining static images of the upper limb in semi-flexion after 10 minutes, and 1 and 2 hours after subcutaneous injection of 1 mCi (37 MBq) of Tc-99m-dextran in the dorsum of the hand. The velocity of axillary lymph node visualization (I, visible at 10 minutes; II, 1 hour; III, 2 hours; and IV, invisible) and degree (intensity) of nodal uptake (a, marked; b, moderate; c,mild; and d, absent) were analyzed. Results: Optimal lymphatic functional pattern (Ia) was observed in four (11%) patients, in the ipsilateral upper limb, and six (19%), in the contralateral upper limb. Worse condition was observed in three (8%) patients (IVd) in the ipsilateral upper limb and two (6%) patients in the contralateral upper limb. The remaining patients showed intermediate states of velocity and uptake intensity. Conclusion: This study found relevant changes in preoperative lymphoscintigraphy, demonstrating preexisting functional differences in the lymphatic system. © 2011 Elsevier Editora Ltda.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To describe the preoperative upper limb lymphoscintigraphic pattern in women with breast cancer. Thirty-seven patients undergoing lymphoscintigraphy within 30 days of surgery were investigated. Lymphoscintigraphic studies of 37 upper limbs ipsilateral to surgery and 32 contralateral upper limbs were performed. The examination protocol consisted in obtaining static images of the upper limb in semi-flexion after 10 minutes, and 1 and 2 hours after subcutaneous injection of 1 mCi (37 MBq) of Tc-99m-dextran in the dorsum of the hand. The velocity of axillary lymph node visualization (I, visible at 10 minutes; II, 1 hour; III, 2 hours; and IV, invisible) and degree (intensity) of nodal uptake (a, marked; b, moderate; c,mild; and d, absent) were analyzed. Optimal lymphatic functional pattern (Ia) was observed in four (11%) patients, in the ipsilateral upper limb, and six (19%), in the contralateral upper limb. Worse condition was observed in three (8%) patients (IVd) in the ipsilateral upper limb and two (6%) patients in the contralateral upper limb. The remaining patients showed intermediate states of velocity and uptake intensity. This study found relevant changes in preoperative lymphoscintigraphy, demonstrating preexisting functional differences in the lymphatic system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)