51 resultados para Ultrasonic waves

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Applications of ultrasound were starting from 1912 with the primary objective the detection of icebergs on prevention of maritime accidents. Algae, fish deaths and destruction were observed in the vicinity of sonar that equipped ships and submarines during the First World War.The evolutions of research and studies with ultrasound have big advances following the discovery of piezoelectric transducers in science and technology. As an example we can mention its application in microsurgery, fatigue detection in aerospace mechanics, catalysis sonochemical, biotechnology and others.The work presented here aims to demonstrate the application of ultrasonic in pulsed mode beams in biotechnology with the aim of improving the fermentation of a culture broth containing biological agents. In these experiments we used as ultrasound equipment and oscilator Sonics VCX-600 (20KHz), probe type wave guide. The experiments were conducted in a glass reactor of 200 mL of biomaterial containing cane juice and Saccharomyces cerevisiae in suspension. The parameters analyzed were related to the content Alcohlic (FID gas chromatography), and cell viability (Neubauer chamber), TRS (refractometry). Analysis of results showed that the total production exceeded in irradiated samples compared to normal fermentation (without ultrasound), suggesting additional advantage of ultrasound activation. Lastin Trials 1400 min, showed ethanol production systems 12% more than non-enabled systems. In this context alternatives for ethanol production, bio fuel and many other byproducts of the alcohol industries and chemicals could benefit from the use of ultrasound beams in this range of frequencies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the last 30 years several studies have been made to understand the relaxation mechanisms of the hydrogen atoms present in transition metals and their alloys. In this work, we observed the stress-induced ordering of hydrogen atoms around the interstitial oxygen atoms near the niobium matrix atoms. We studied this relaxation process by measuring the attenuation of longitudinal ultrasonic waves. These measurements were made in Nb1.0%Zr polycrystalline alloys at 10 and 30 MHz, pure and doped with 0.7 and 4.2 at.% hydrogen. The results revealed a thermally activated relaxation structure around 202 K and 235 K for 10 MHz and 30 MHz respectively. This relaxation structure increases with increasing hydrogen concentration. © 1994.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper adresses the problem on processing biological data such as cardiac beats, audio and ultrasonic range, calculating wavelet coefficients in real time, with processor clock running at frequency of present ASIC's and FPGA. The Paralell Filter Architecture for DWT has been improved, calculating wavelet coefficients in real time with hardware reduced to 60%. The new architecture, which also processes IDWT, is implemented with the Radix-2 or the Booth-Wallace Constant multipliers. Including series memory register banks, one integrated circuit Signal Analyzer, ultrasonic range, is presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Secondary phases such as Laves and carbides are formed during the final solidification stages of nickel based superalloy coatings deposited during the gas tungsten arc welding cold wire process. However, when aged at high temperatures, other phases can precipitate in the microstructure, like the γ″ and δ phases. This work presents a new application and evaluation of artificial intelligent techniques to classify (the background echo and backscattered) ultrasound signals in order to characterize the microstructure of a Ni-based alloy thermally aged at 650 and 950 °C for 10, 100 and 200 h. The background echo and backscattered ultrasound signals were acquired using transducers with frequencies of 4 and 5 MHz. Thus with the use of features extraction techniques, i.e.; detrended fluctuation analysis and the Hurst method, the accuracy and speed in the classification of the secondary phases from ultrasound signals could be studied. The classifiers under study were the recent optimum-path forest (OPF) and the more traditional support vector machines and Bayesian. The experimental results revealed that the OPF classifier was the fastest and most reliable. In addition, the OPF classifier revealed to be a valid and adequate tool for microstructure characterization through ultrasound signals classification due to its speed, sensitivity, accuracy and reliability. © 2013 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Several Lamb wave modes can be coupled to a particular structure, depending on its geometry and transducer used to generate the guided waves. Each Lamb mode interacts in a particular form with different types of defects, like notches, delamination, surface defects, resulting in different information which can be used to improve damage detection and characterization. An image compounding technique that uses the information obtained from different propagation modes of Lamb waves for non-destructive testing of plate-like structures is proposed. A linear array consisting of 16 piezoelectric elements is attached to a 1 mm thickness aluminum plate, coupling the fundamental A0 and S0 modes at the frequencies of 100 kHz and 360 kHz, respectively. For each mode two images are obtained from amplitude and phase information: one image using the Total Focusing Method (TFM) and one phase image obtained from the Sign Coherence Factor (SCF). Each TFM image is multiplied by the SCF image of the respective mode to improve contrast and reduce side and grating lobes effects. The high dispersive characteristic of the A0 mode is compensated for adequate defect detection. The information in the SCF images is used to select one of the TFM mode images, at each pixel, to obtain the compounded image. As a result, dead zone is reduced, resolution and contrast are improved, enhancing damage detection when compared to the use of only one mode. © 2013 Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ciências Biológicas (Microbiologia Aplicada) - IBRC

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The application of ultrasonic waves during the initial setting of the glass ionomer cements (GIC) has demonstrated increase of the cure speed, reduction of air bubbles and improves in some mechanical properties. The aim of this study was to evaluate the effect of the ultrasound on the microhardness and the superficial roughness in two GICs (FUJI IX GP (GC Corporation) and Ketac Molar EasyMix (3M ESPE)). Forty specimens were confectioned, twenty for evaluation of the superficial roughness and twenty for evaluation of the microhardness. Half of them received for thirty seconds the ultrasonic waves application. The readings of the roughness had been carried before and after the toothbrushing test. The twenty remaining specimens had been polished with abrasive sandpapers of decreasing granulations and submitted to the hardness test. The results, analyzed for the variance analysis (ANOVA) (p<0,05), had demonstrated increase of the hardness for all the groups with the application of ultrasonic waves, being bigger for the Ketac Molar EasyMix. The ultrasound application also caused significant reduction of the superficial roughness for the Ketac Molar EasyMix. After the toothbrushing test, this last property increased for all the materials. It could be concluded that the application of ultrasonic waves was effective in increasing the superficial hardness of the materials and that it improved the roughness of the Ketac Molar EasyMix before the toothbrushing test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a cell to measure dynamic viscosity of liquids using ultrasonic wave mode conversion from longitudinal to shear wave. The strategy used to obtain the viscosity is based on the measurement of the complex reflection coefficient of shear waves at a solid-liquid interface. Viscosity measurements of automotive oils (SAE90 and SAE140) were obtained in the frequency range from 1 to 10 MHz. These results are compared with the Maxwell model with two relaxation times, showing the dependency of viscosity with frequency. Several parameters affecting viscosity measurements, including the solid material properties, liquid viscosity, and operating frequency are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Piezoelectric array transducers applications are becoming usual in the ultrasonic non-destructive testing area. However, the number of elements can increase the system complexity, due to the necessity of multichannel circuitry and to the large amount of data to be processed. Synthetic aperture techniques, where one or few transmission and reception channels are necessary, and the data are post-processed, can be used to reduce the system complexity. Another possibility is to use sparse arrays instead of a full-populated array. In sparse arrays, there is a smaller number of elements and the interelement spacing is larger than half wavelength. In this work, results of ultrasonic inspection of an aluminum plate with artificial defects using guided acoustic waves and sparse arrays are presented. Synthetic aperture techniques are used to obtain a set of images that are then processed with an image compounding technique, which was previously evaluated only with full-populated arrays, in order to increase the resolution and contrast of the images. The results with sparse arrays are equivalent to the ones obtained with full-populated arrays in terms of resolution. Although there is an 8 dB contrast reduction when using sparse arrays, defect detection is preserved and there is the advantage of a reduction in the number of transducer elements and data volume. © 2013 Brazilian Society for Automatics - SBA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)