139 resultados para Thermal energy
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Photoassociation is a possible route for the formation of chemical bonds. In this process, the binding of colliding atoms can be induced by means of a laser field. Photoassociation has been studied in the ultracold regime and also with temperatures well above millikelvins in the thermal energy domain, which is a situation commonly encountered in the laboratory. A photoassociation mechanism can be envisioned based on the use of infrared pulses to drive a transition from free colliding atoms on the electronic ground state to form a molecule directly on that state. This work takes a step in this direction, investigating the laser-pulse-driven formation of heteronuclear diatomic molecules in a thermal gas of atoms including rotational effects. Based on the assumption of full system controllability, the maximum possible photoassociation yield is deduced. The photoassociation probability is calculated as a function of the laser parameters for different temperatures. Additionally, the photoassociation yield induced by subpicosecond pulses of a priori fixed shape is compared to the maximum possible yield.
Resumo:
Nove vacas Holandesas lactantes com 526 ± 5 kg de peso corporal (cinco predominantemente pretas e quatro predominantemente brancas), criadas em região tropical e manejadas em pastagens, foram observadas com os objetivos de determinar simultaneamente as taxas de evaporação cutânea e respiratória em ambiente tropical e desenvolver modelos de predição. Para a medição da perda de calor latente pela superfície corporal, utilizou-se uma cápsula ventilada e, para a perda por respiração, utilizou-se uma máscara facial. Os resultados mostraram que as vacas que tinham maior peso corporal (classe 2 e 3) apresentaram maiores taxas evaporativas. Quando a temperatura do ar aumentou de 10 para 36ºC e a umidade relativa do ar caiu de 90 para 30%, a eliminação de calor por evaporação respiratória aumentou de aproximadamente 5 para 57 W m-2 e a evaporação na superfície corporal passou de 30 para 350 W m-2. Esses resultados confirmam que a eliminação de calor latente é o principal mecanismo de perda de energia térmica sob altas temperaturas (>30ºC); a evaporação cutânea é a maior via e corresponde a aproximadamente 85% da perda total de calor, enquanto o restante é eliminado pelo sistema respiratório. O modelo para predizer o fluxo de perda de calor latente baseado em variáveis fisiológicas e ambientais pode ser utilizado para estimar a contribuição da evaporação na termorregulação, enquanto o modelo baseado somente na temperatura do ar deve ser usado apenas para a simples caracterização do processo evaporativo.
Resumo:
O objetivo deste estudo foi avaliar a viabilidade econômica da implantação de dois biodigestores com uso de dejetos animais em área do Assentamento de Trabalhadores Rurais no município de Itaberá - SP, no ano de 2005; um deles para o fornecimento de energia para os domicílios e outro para as atividades produtivas. Foram avaliados os benefícios referentes ao fornecimento de energia elétrica e térmica, a partir do biogás, para cinco domicílios da agrovila do assentamento e para as atividades produtivas, comparativamente aos custos de construção e operação para produção de biogás. Os resultados mostraram a viabilidade econômica da produção de gás em ambos os biodigestores. Foram gerados benefícios no valor de R$ 3.698,00 por ano e R$ 9.080,57 por ano, nos biodigestores para os domicílios e produção, respectivamente; bem como o equivalente a R$ 1.478,28 por ano referentes à produção de biofertilizante. O custo anual do processo é de R$ 1.218,50 em cada biodigestor. O prazo de recuperação do investimento é de 2,5 anos e 11 meses, para a produção de biogás nos domicílios e na produção, respectivamente. Os resultados podem ser utilizados para subsidiar políticas públicas direcionadas ao aproveitamento de biomassa para a produção de energia a baixos custos no segmento da agricultura familiar.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this Letter, an entropy operator for the general unitary SU(1, 1) TFD formulation is proposed and used to lead a bosonic system from zero to finite temperature. Namely, considering the closed bosonic string as the target system, the entropy operator is used to construct the thermal vacuum. The behaviour of such a state under the breve conjugation rules is analyzed and it was shown that the breve conjugation does not affect the thermal effects. From this thermal vacuum the thermal energy, the entropy and the free energy of the closed bosonic string are calculated and the appropriated thermal distribution for the system is found after the free energy minimization. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Sharp transitions are perhaps absent in QCD, so that one looks for physical quantities which may reflect the phase change. One such quantity is the sound velocity which was shown in lattice theory to become zero at the transition point for pure glue. We show that even in a simple bag model the sound velocity goes to zero at temperature T = T(v) not-equal 0 and that the numerical value of this T(v) depends on the nature of the meson. The average thermal energy of mesons goes linearly with T near T(v), with much smaller slope for the pion. The T(v) - s can be connected with the Boltzmann temperatures obtained from transverse momentum spectrum of these mesons in heavy-ion collision at mid-rapidity. It would be interesting to check the presence of different T(v) - s in present day finite T lattice theory.
Resumo:
Drying kinetics of tomato was studied by using heat pump dryer (HPD) and electric resistance dryers with parallel and crossed airflow. The performance of both systems was evaluated and compared and the influence of temperature, air velocity, and tomato type on the drying kinetics was analyzed. The use of HPD showed to be adequate in the drying process of tomatoes, mainly in relation to the conversion rate of electric energy into thermal energy. The heat pump effective coefficient of performance (COPHT,EF) was between 2.56 and 2.68, with an energy economy of about 40% when compared to the drying system with electric resistance. The Page model could be used to predict drying time of tomato and statistical analysis showed that the model parameters were mainly affected by drying temperature.
Resumo:
In this paper we present technical and economic studies of cogeneration systems utilizing combustion engines and gas turbines, applied in two establishments of the tertiary sector, regarding Brazilian conditions (according to Silveria, 1994). In the first step cogeneration systems utilizing combustion engines associated to absorption refrigeration systems are studied, in which electricity and cold air for a university building rate produced. In the second step some possibilities of the use of the gas turbine in cogeneration systems for a hospital are shown. In this case, the exhaust gases are utilized for the production of steam in a heat recovery steam generator (HRSG) or cold water in an absorption refrigeration system (for air conditioning) for the hospital building. The dynamic increment of the energy demand of Brazilian tertiary sector in last years can increase the installation of these cogeneration system (in compact version) as well as strengthen the development of the decentralized energy generation in Brazil.
Resumo:
The electronic structure of Mg impurity in zincblende (c-)GaN is investigated by using the ab initio full potential linear-augmented plane-wave method and the local density-functional approximation. Full geometry optimization calculations, including nearest and next-nearest neighbor displacements, are performed for the impurity in the neutral and negatively charged states. A value of 190 ± 10 meV was obtained for the Franck-Condon shift to the thermal energy, which is in good agreement with that observed in recent low temperature photoluminescence and Hall-effect measurements. We conclude that the nearest and next-nearest neighbors of the Mg impurity replacing Ga in C-GaN undergo outward relaxations which play an important role in the determination of the center acceptor energies.
Resumo:
The current technological development made by the absorption refrigeration system is an economic and ambient alternative in comparison to the vapor cycle, possessing an advantage that uses thermal energy that is less noble. Chillers of absorption are used widely in the air conditioned industries, because they can be set in motion through hot water vapors that burn natural gas, solar energy, biomasses amongst others instead of electricity. These systems allow it to reduce the tips of electric demand and balance the rocking of energy demand. This work has had a main objective to simulate a absorption refrigeration cycle with lithium-water bromide solution using biogas of sanitary landfill, and mixtures of this with natural gas. These results shown to the energy viability of the system burning biogas and its mixtures with natural gas in the generator, when compared with equipments that uses traditional fuels (natural gas, oil diesel, amongst others), for operation the commercial chillers with 15 kW of the refrigeration capacity and temperature of the water in the entrance of 14°C and the exit of 7°C.
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA