46 resultados para Test data generation
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
This work shows a computational methodology for the determination of synchronous machines parameters using load rejection test data. The quadrature axis parameters are obtained with a rejection under an arbitrary reference, reducing the present difficulties.
Resumo:
This work shows a computational methodology for the determination of synchronous machines parameters using load rejection test data. By machine modeling one can obtain the quadrature parameters through a load rejection under an arbitrary reference, reducing the present difficulties. The proposed method is applied to a real machine.
Resumo:
HLA-E is a non-classical Human Leucocyte Antigen class I gene with immunomodulatory properties. Whereas HLA-E expression usually occurs at low levels, it is widely distributed amongst human tissues, has the ability to bind self and non-self antigens and to interact with NK cells and T lymphocytes, being important for immunosurveillance and also for fighting against infections. HLA-E is usually the most conserved locus among all class I genes. However, most of the previous studies evaluating HLA-E variability sequenced only a few exons or genotyped known polymorphisms. Here we report a strategy to evaluate HLA-E variability by next-generation sequencing (NGS) that might be used to other HLA loci and present the HLA-E haplotype diversity considering the segment encoding the entire HLA-E mRNA (including 5'UTR, introns and the 3'UTR) in two African population samples, Susu from Guinea-Conakry and Lobi from Burkina Faso. Our results indicate that (a) the HLA-E gene is indeed conserved, encoding mainly two different protein molecules; (b) Africans do present several unknown HLA-E alleles presenting synonymous mutations; (c) the HLA-E 3'UTR is quite polymorphic and (d) haplotypes in the HLA-E 3'UTR are in close association with HLA-E coding alleles. NGS has proved to be an important tool on data generation for future studies evaluating variability in non-classical MHC genes.
Resumo:
The aim was to study the efficiency of electrical conductivity test in evaluating the quality of castor seeds. Emergence of seedlings was evaluated in the field, with five seed lots of cv. AL Guarany 2002. The seeds were submitted to the following tests: germination; first count of germination; accelerated aging (45 degrees C by 24 to 100% UR), emergence of seedlings in the field, rate of speed of development of seedlings and electrical conductivity, testing the periods (2, 4, 6, 8 and 24 hours) and the number of seeds (25,50 and 75) in 75ml of distilled water conditioning to 25 degrees C. A completely randomized design was used. The averages were compared by the Tukey test at 5%. The mean laboratory and field test data were correlated. Electrical conductivity test for 4 hours with 25 seeds and 6 hours with 50 seeds, and the rate of speed emergency proved efficient in the selection of lots vigor by providing information equivalent to the emergence of seedlings in the field.
Resumo:
Os objetivos do estudo foram avaliar o alinhamento, no plano sagital, da coluna de indivíduos com alterações na medida da gibosidade, comparando com um grupo sem alterações; testar a confiabilidade do instrumento utilizado e verificar se existem correlações entre as medidas da gibosidade e os valores das curvaturas vertebrais. Foram avaliados 40 jovens, divididos em grupo controle - ausência ou presença de gibosidades inferiores a 0,5 cm na curvatura torácica e 0,7 cm na lombar (n=20) e, grupo experimental - gibosidades superiores às descritas (n=20). A gibosidade e as curvaturas no plano sagital foram mensuradas com um instrumento adaptado a um nível d'água e o teste de Adams. As coletas foram realizadas em duas datas distintas, nos dois grupos. Após aplicação do teste Mann-Whitney não foi encontrada diferença entre as ocasiões de coletas e, emparelhando-se os grupos, foi encontrada diferença apenas na medida cervical. Na verificação de existência de relação entre as medidas coletadas, foi encontrada correlação linear (Spearmann) no grupo controle - curvatura torácica e gibosidade torácica; em ambos os grupos - curvaturas torácica e lombar; e no grupo experimental - gibosidade torácica e as curvaturas lombar e sacral e, curvatura sacral e curvaturas torácica e lombar. Pôde-se concluir que a medida da gibosidade tem relações com as curvaturas no plano sagital. Por ser um método confiável, simples e acessível, pode ser reproduzido sem altos custos financeiros e sem causar prejuízo à saúde do paciente.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Background and Objective: evaluate the adhesion of adhesive restorations with and without a base of resin-modified glass-ionomer cement (RMGIC) to dentin irradiated with Er:YAG laser.Study Design/Materials and Methods: Twenty-four human molar teeth were divided into 6 groups (n=4): G1) 37% Phosphoric acid (PA) + Adhesive system (Ad) + Composite resin (CR); G2) RMGIC + CR; G3) Laser (60mJ-5Hz-20s) + PA + Ad + CR; G4) Laser (60 mJ-5 Hz-20 s) + RMGIC + CR; G5) Laser (100mJ-5Hz-20s) + PA + Ad + CR; G6) Laser (100mJ-5Hz-20s) + RMGIC + CR. Teeth were prepared, restored and cut into specimens, according to the treatment proposed and to methodology for microtensile test. Data were submitted to ANOVA and Tukey statistical tests (alpha=5%).Results:. The mean values for adhesion (MPa) and standard deviation (+/- SD) were: G1) 26.30(+/- 4.50), G2) 5.34(+/- 2.87), G3) 21.16(+/- 6.01), G4) 5.22(+/- 1.52), G5) 22.23(+/- 4.98), G6) 5.25(+/- 3.08).Conclusion: the use of Er:YAG laser did not influence on the restorations adhesion.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Os testes de vigor são empregados pelas empresas produtoras de sementes, no controle interno de qualidade. Dentre estes, o teste de comprimento de plântulas tem potencial para ser usado para este fim. Assim, o trabalho objetivou verificar a possibilidade de utilização do teste de comprimento de plântulas como um método de vigor para classificar lotes de sementes de soja de acordo com a sua qualidade fisiológica. Para tanto, variou-se a forma de apresentação dos resultados médios de comprimento de plântulas e de suas partes (raiz e hipocótilo). A qualidade fisiológica de três lotes de soja (Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA) 48), de mesma classe de tamanho e com teor de água semelhante, foi avaliada por testes de viabilidade e vigor, realizados em laboratório e campo. Empregou-se delineamento inteiramente casualizado. As médias foram comparadas pelo teste de Tukey a 5% de probabilidade. Correlacionaram-se os dados médios dos testes realizados em laboratório e em campo. O comprimento da raiz de soja foi mais sensível para diferenciar lotes, apresentando maior correlação com a emergência das plântulas de soja em campo. O comprimento de plântulas ou de suas partes distinguiram os três lotes de soja somente quando seus resultados médios foram divididos pelo número de sementes em teste, mostrando ser a forma mais eficaz para classificar lotes de alta qualidade e com diferenças sutis de vigor.
Resumo:
Pathogenic variation in Colletotrichum gloeosporioides infecting species of the tropical pasture legume Stylosanthes at its center of diversity was determined from 296 isolates collected from wild host population and selected germ plasm of S. capitata, S. guianensis, S. scabra, and S. macrocephala in Brazil. A putative host differential set comprising 11 accessions was selected from a bioassay of 18 isolates on 19 host accessions using principal component analysis. A similar analysis of anthracnose severity data for a subset of 195 isolates on the 11 differentials indicated that an adequate summary of pathogenic variation could be obtained using only five of these differentials. of the five differentials, S. seabrana 'Primar' was resistant and S. scabra 'Fitzroy' was susceptible to most isolates. A cluster analysis was used to determine eight natural race clusters using the 195 isolates. Linear discriminant functions were developed for eight race clusters using the 195 isolates as the training data set, and these were applied to classify a test data set of the remaining 101 isolates. All except 11 isolates of the test data set were classified into one of the eight race clusters. Over 10% of the 296 isolates were weakly pathogenic to all five differentials and another 40% were virulent on just one differential. The unclassified isolates represent six new races with unique virulence combinations, of which one isolate is virulent on all five differentials. The majority of isolates came from six field sites, and Shannon's index of diversity indicated considerable variation between sites. Pathogenic diversity was extensive at three sites where selected germ plasm were under evaluation, and complex race clusters and unclassified isolates representing new races were more prevalent at these sites compared with sites containing wild Stylosanthes populations.
Resumo:
The code STATFLUX, implementing a new and simple statistical procedure for the calculation of transfer coefficients in radionuclide transport to animals and plants, is proposed. The method is based on the general multiple-compartment model, which uses a system of linear equations involving geometrical volume considerations. Flow parameters were estimated by employing two different least-squares procedures: Derivative and Gauss-Marquardt methods, with the available experimental data of radionuclide concentrations as the input functions of time. The solution of the inverse problem, which relates a given set of flow parameter with the time evolution of concentration functions, is achieved via a Monte Carlo Simulation procedure.Program summaryTitle of program: STATFLUXCatalogue identifier: ADYS_v1_0Program summary URL: http://cpc.cs.qub.ac.uk/summaries/ADYS_v1_0Program obtainable from: CPC Program Library, Queen's University of Belfast, N. IrelandLicensing provisions: noneComputer for which the program is designed and others on which it has been tested: Micro-computer with Intel Pentium III, 3.0 GHzInstallation: Laboratory of Linear Accelerator, Department of Experimental Physics, University of São Paulo, BrazilOperating system: Windows 2000 and Windows XPProgramming language used: Fortran-77 as implemented in Microsoft Fortran 4.0. NOTE: Microsoft Fortran includes non-standard features which are used in this program. Standard Fortran compilers such as, g77, f77, ifort and NAG95, are not able to compile the code and therefore it has not been possible for the CPC Program Library to test the program.Memory, required to execute with typical data: 8 Mbytes of RAM memory and 100 MB of Hard disk memoryNo. of bits in a word: 16No. of lines in distributed program, including test data, etc.: 6912No. of bytes in distributed Program, including test data, etc.: 229 541Distribution format: tar.gzNature of the physical problem: the investigation of transport mechanisms for radioactive substances, through environmental pathways, is very important for radiological protection of populations. One such pathway, associated with the food chain, is the grass-animal-man sequence. The distribution of trace elements in humans and laboratory animals has been intensively studied over the past 60 years [R.C. Pendlenton, C.W. Mays, R.D. Lloyd, A.L. Brooks, Differential accumulation of iodine-131 from local fallout in people and milk, Health Phys. 9 (1963) 1253-1262]. In addition, investigations on the incidence of cancer in humans, and a possible causal relationship to radioactive fallout, have been undertaken [E.S. Weiss, M.L. Rallison, W.T. London, W.T. Carlyle Thompson, Thyroid nodularity in southwestern Utah school children exposed to fallout radiation, Amer. J. Public Health 61 (1971) 241-249; M.L. Rallison, B.M. Dobyns, F.R. Keating, J.E. Rall, F.H. Tyler, Thyroid diseases in children, Amer. J. Med. 56 (1974) 457-463; J.L. Lyon, M.R. Klauber, J.W. Gardner, K.S. Udall, Childhood leukemia associated with fallout from nuclear testing, N. Engl. J. Med. 300 (1979) 397-402]. From the pathways of entry of radionuclides in the human (or animal) body, ingestion is the most important because it is closely related to life-long alimentary (or dietary) habits. Those radionuclides which are able to enter the living cells by either metabolic or other processes give rise to localized doses which can be very high. The evaluation of these internally localized doses is of paramount importance for the assessment of radiobiological risks and radiological protection. The time behavior of trace concentration in organs is the principal input for prediction of internal doses after acute or chronic exposure. The General Multiple-Compartment Model (GMCM) is the powerful and more accepted method for biokinetical studies, which allows the calculation of concentration of trace elements in organs as a function of time, when the flow parameters of the model are known. However, few biokinetics data exist in the literature, and the determination of flow and transfer parameters by statistical fitting for each system is an open problem.Restriction on the complexity of the problem: This version of the code works with the constant volume approximation, which is valid for many situations where the biological half-live of a trace is lower than the volume rise time. Another restriction is related to the central flux model. The model considered in the code assumes that exist one central compartment (e.g., blood), that connect the flow with all compartments, and the flow between other compartments is not included.Typical running time: Depends on the choice for calculations. Using the Derivative Method the time is very short (a few minutes) for any number of compartments considered. When the Gauss-Marquardt iterative method is used the calculation time can be approximately 5-6 hours when similar to 15 compartments are considered. (C) 2006 Elsevier B.V. All rights reserved.
Resumo:
The dilatometer test results have been lately applied in foundation design for prediction of settlement and bearing capacity problems. The equipment, its calibration, test procedures and test data interpretation are simple. These advantages seem to explain the increasing use of the dilatometer (DMT) test as a routine technique for subsoil investigation. The DMT test boreholes were carried out on the grounds of the National Research Council (NRC) in Ottawa. Several test results based on laboratory, and other in situ tests available in the literature for the Leda clay deposit in Ottawa area were used to provide correlations between geotechnical properties and soil index parameters as proposed by Marchetti (1980). More appropriated relationships, even though preliminaries, are presented for the crust layer.
Resumo:
A site investigation program was carried out to detect salt-water intrusions in a shallow sedimentary aquifer based on electrical resistivity measurements. The site is located close to Paranaguá harbor, in the Paraná State, Brasil. At this site, high chloride concentration contaminated shallow water wells used to supply water for local industries. The site investigation program included a fieldwork, dipole-dipole electrical profiling, resistivity piezocone tests, physical-chemical analysis of sampled water and interpretation of borehole logs. The resistivity piezocone tests provided two simultaneous information; the soil stratigraphy at a very detailed level and a quasi-continuous resistivity profile. Both information adequately complemented dipole-dipole electrical profiling test data. The integration of all test data allowed identifying the contaminated areas as well as guided the location of new water wells to be installed in this area.
Resumo:
This study evaluated the effect of water-bath and microwave post-polymerization treatments on the flexural strength and Vickers hardness of four autopolymerizing reline resins (Duraliner II-D, Kooliner-K, Tokuso Rebase Fast-TR and Ufi Gel Hard C-UGH) and one heat-polymerized acrylic resin (Lucitone 550-L), processed using two polymerization cycles (short cycle - 90 minutes at 73°C and 100°C for 30 minutes; and long cycle - 9 hours at 71°C). For each material, thirty specimens (64 x 10 x 3.3 mm) were made and divided into 3 groups (n=10). Specimens were tested after: processing (control group); water-bath at 55°C for 10 minutes (reline materials) or 60 minutes (L); and microwave irradiation. Flexural strength tests were performed at a crosshead speed of 5 mm/min using a three-point bending device with a span of 50 mm. The flexural strengths values were calculated in MPa. One fragment of each specimen was submitted to Vickers hardness test. Data were analyzed by 2-way ANOVA followed by Tukey's HSD test (α=0.05). L microwaved specimens (short cycle) exhibited significantly higher flexural strength means than its respective control group (p<0.05). Water-bath promoted a significant increase (p<0.05) in flexural strength of K and L (long cycle). The hardness of the tested materials was not influenced by the post-polymerization treatments. Post-polymerization treatments could be used to improve the flexural strength of some materials tested.
Resumo:
Water is the raw material used most in the production of diverse pharmaceutical forms and, being a constituent of the formulation itself, is subject to a number of physico-chemical and microbiological specifications. In addition, it is indispensable for laboratory tests and the cleaning of equipment and apparatus. The aim of this study was to ascertain the degree of physicochemical and microbiological contamination of purified water used in compounding pharmacies in the city of São José do Rio Preto, SP, Brazil. Samples were taken as recommended in the USP Pharmacopeia, with careful aseptic technique, and sent immediately the to quality control laboratory. Physicochemical properties were analyzed, including appearance, pH, conductivity, residue after evaporation, ammonia, calcium, chloride, heavy metals, sulfate and oxidizable substances, and microbiological tests were performed: total aerobic microbial count and detection of total and thermotolerant coliforms and Pseudomonas aeruginosa. Results showed that some parameters did not conform to the standards, especially pH, conductivity, inorganic impurities, oxidizable substances and microbiological test data, in 10%, 17%, 10%, 14% and 20% of the analyzed samples, respectively, This points to the need for greater care in the production and/or storage of purified water in these pharmaceutical establishments.