133 resultados para TAP
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
p-Phenylenediamine (PPD) and resorcinol (RSN) are hair dye precursors of permanent dyeing more used worldwide. The present work describes a simple and economic voltammetric sensor for simultaneous determination of both components in commercial hair dyeing and tap water at low concentrations. PPD and RSN are oxidized at + 0.17 and + 0.61 V vs. Ag/AgCl at glassy carbon electrode coated by composites of multiwall carbon nanotubes with chitosan (MWNTs-CHT/GCE), which anodic currents density normalized are 10% and 70% higher in relation to the unmodified electrode, respectively. The calibration curve for simultaneous determination of PPD and RSN showed linearity between 0.55 and 21.2 mg L-1 with detection limits of 0.79 and 0.58 mg L-1 to PPD and RSN, respectively. The relative standard deviations found for ten determinations were of 0.73 and 2.35% to 2.70 mg L-1, and 0.87 and 1.08% to 15.96 mg L-1 to PPD and RSN, respectively. The voltammetric sensor was applied to determination of PPD and RSN in tap water and commercial hair dyeing samples and the average recovery for these samples was around 97%. The products generated from PPD and RSN reaction such as was p-quinonediimine and bandrowski base were detected by LC-MS/MS and UV-vis spectrophotometry. (C) 2014 Published by Elsevier B.V.
Resumo:
Sementes de Psidium cattleianum foram acondicionadas em embalagens permeável, semipermeável e impermeável e armazenadas em ambiente não controlado, câmara seca e câmara fria por 1.107 dias, com o objetivo de avaliar a qualidade fisiológica. Desde o início do armazenamento das sementes, e após cada período de 123 dias, foram avaliados o teor de água, a porcentagem e o índice de velocidade de germinação e a condutividade elétrica da solução de embebição. Nos testes de germinação e de condutividade elétrica, as sementes foram previamente imersas em ácido sulfúrico durante 25 minutos, depois lavadas em água corrente e em água destilada. As sementes foram colocadas para germinar, entre vermiculita, na temperatura alternada de 20-30 ºC, sob lâmpadas fluorescentes brancas, com fotoperíodo de 8 horas. O acondicionamento das sementes em embalagem impermeável e o armazenamento em ambiente natural de laboratório ou em câmara seca, bem como o acondicionamento em embalagem semipermeável e armazenamento em câmara fria, são adequados para a conservação das sementes durante 1.107 dias.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Aims: The aim of this study was to identify and determine the diversity, occurrence and distribution of fungi in water used at a haemodialysis centre.Methods and Results: Samples in the hydraulic circuit for the distribution of the water, dialysate samples and samples of sterilization solution from dialysers were collected over a 3-month period, and 500 ml of each sample was filtered through membranes. All together 116 isolates of fungi were recovered from 89% of all water samples collected inside the haemodialysis unit, with prevalence of moulds in tap water samples and of yeasts in dialysate samples. Fusarium spp. was the most abundant genus found, whereas Candida parapsilosis was the predominant yeast species.Conclusions: This study demonstrated that various fungi were present in the water system. These data suggest the inclusion of the detection and quantification of fungi in the water of haemodialysis.Significance and Impact of the Study: The recovery of fungi from aqueous haemodialysis environments implies a potential risk for haemodialysis patients and indicates the need for continuous maintenance and monitoring. Further studies on fungi in haemodialysis water systems are required to investigate the organism ability to persist, their role in biofilm formation and their clinical significance.
Resumo:
The microbiological monitoring of the water used for hemodialysis is extremely important, especially because of the debilitated immune system of patients suffering from chronic renal insufficiency. To investigate the occurrence and species diversity of bacteria in waters, water samples were collected monthly from a hemodialysis center in upstate São Paulo and tap water samples at the terminal sites of the distribution system was sampled repeatedly (22 times) at each of five points in the distribution system; a further 36 samples were taken from cannulae in 19 hemodialysis machines that were ready for the next patient, four samples from the reuse system and 13 from the water storage system. To identify bacteria, samples were filtered through 0.22 mu m-pore membranes; for mycobacteria, 0.45 mu m pores were used. Conventional microbiological and molecular methods were used in the analysis. Bacteria were isolated from the distribution system (128 isolates), kidney machine water (43) and reuse system (3). Among these isolates, 32 were Gram-positive rods, 120 Gram-negative rods, 20 Gram-positive cocci and 11 mycobacteria. We propose the continual monitoring of the water supplies in hemodialysis centers and the adoption of effective prophylactic measures that minimize the exposure of these immunodeficient patients to contaminated sources of water.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The conventional Newton and fast decoupled power flow (FDPF) methods have been considered inadequate to obtain the maximum loading point of power systems due to ill-conditioning problems at and near this critical point. It is well known that the PV and Q-theta decoupling assumptions of the fast decoupled power flow formulation no longer hold in the vicinity of the critical point. Moreover, the Jacobian matrix of the Newton method becomes singular at this point. However, the maximum loading point can be efficiently computed through parameterization techniques of continuation methods. In this paper it is shown that by using either theta or V as a parameter, the new fast decoupled power flow versions (XB and BX) become adequate for the computation of the maximum loading point only with a few small modifications. The possible use of reactive power injection in a selected PV bus (Q(PV)) as continuation parameter (mu) for the computation of the maximum loading point is also shown. A trivial secant predictor, the modified zero-order polynomial which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used in predictor step. These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approach for the IEEE test systems (14, 30, 57 and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that parameters can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The parameterized fast decoupled power flow (PFDPF), versions XB and BX, using either theta or V as a parameter have been proposed by the authors in Part I of this paper. The use of reactive power injection of a selected PVbus (Q(PV)) as the continuation parameter for the computation of the maximum loading point (MLP) was also investigated. In this paper, the proposed versions obtained only with small modifications of the conventional one are used for the computation of the MLP of IEEE test systems (14, 30, 57 and 118 buses). These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approaches are presented and discussed. The results show that the characteristics of the conventional FDPF method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that these versions can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. A trivial secant predictor, the modified zero-order polynomial, which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used for the predictor step. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The conventional Newton and fast decoupled power flow methods are considered inadequate for obtaining the maximum loading point of power systems due to ill-conditioning problems at and near this critical point. At this point, the Jacobian matrix of the Newton method becomes singular. In addition, it is widely accepted that the P-V and Q-theta decoupling assumptions made for the fast decoupled power flow formulation no longer hold. However, in this paper, it is presented a new fast decoupled power flow that becomes adequate for the computation of the maximum loading point by simply using the reactive power injection of a selected PV bus as a continuation parameter. Besides, fast decoupled methods using V and 0 as parameters and a secant predictor are also presented. These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained for the IEEE systems (14 and 118 buses) show that the characteristics of the conventional method are enhanced and the region of convergence around the singular solution is enlarged.
Resumo:
Os métodos de fluxo de carga por Newton-Raphson e fluxo de carga desacoplado rápido convencionais são considerados inadequados para a obtenção do ponto de máximo carregamento de sistemas de potência, devido à problemas de mal-condicionamento neste ponto crítico e na sua vizinhança. Neste ponto a matriz Jacobiana do método de Newton-Raphson torna-se singular e considera-se que não são mais válidas as hipóteses de desacoplamento P-V e Q-teta utilizadas para a formulação do método fluxo de carga desacoplado rápido. No entanto, mostra-se neste trabalho, que com pequenas modificações, as versões XB e BX do fluxo de carga desacoplado rápido tornam-se adequadas para a obtenção do ponto de máximo carregamento. Estas novas versões modificadas são comparadas entre si com o intuito de explicitar suas características, assim como da influência da atuação dos limites de geração de potência reativa e de tap's de transformadores. Os resultados obtidos para os sistemas testes do IEEE (14, 30, 57 e 118 barras) mostram que as características de convergência das versões originais são preservadas. Além disso, durante o traçado das curvas PV, os diversos métodos podem ser comutados entre si possibilitando o cálculo de todos os pontos da curva com um número reduzido de iterações.
Resumo:
Avaliou-se a contaminação da casca e do conteúdo interno de ovos inoculados com Salmonella enterica sorovar enteritidis fagotipo 4, lavados com água de torneira (AT) ou solução de amônia quaternária (AQ) e armazenados a 8ºC e 25ºC. Duzentos e cinqüenta e dois ovos foram divididos em três grupos. Os tratamentos de cada grupo consistiram de imersão em AT, AQ a 25ºC e a 43ºC. Após a secagem natural, todos os grupos foram contaminados com solução de S. enteritidis. Seguindo-se a contaminação, cada grupo tratado foi estocado a 8ºC ou 25ºC, e a presença de S. enteritidis na casca e no conteúdo interno foi avaliada após zero, 24, 96 e 168 horas. A sanitização com AQ mostrou-se eficiente na redução de S. enteritidis nas cascas dos ovos. O armazenamento dos ovos a 8ºC demonstrou ser preponderante na redução e na ausência de S. enteritidis na casca. Nos ovos lavados com AT, o armazenamento a 25ºC permitiu a permanência da bactéria nas cascas até 168 horas. Não se detectou S. enteritidis no conteúdo interno dos ovos em nenhum dos grupos.
Resumo:
Este estudo descritivo coletou informações sociodemográficas, obstétricas e relacionadas ao diagnóstico e tratamento da gestante/puérpera e parceiro das 67 gestantes/puérperas notificadas no Sistema Nacional de Agravos de Notificação, usuárias de maternidades públicas do Distrito Federal, Brasil, entre 2009 e 2010. As informações do acompanhamento clínico e laboratorial recebido pela criança vieram do prontuário médico hospitalar, fichas de notificação compulsória e Cartão da Criança. Das gestantes, 41,8% foram adequadamente tratadas, o principal motivo para a inadequação foi a ausência (83,6%) ou inadequação do tratamento do parceiro (88,1%). Mais de um terço necessitou de novo tratamento na maternidade por falta de documentação terapêutica no pré-natal. Dos recém-nascidos com sífilis congênita, 48% fizeram estudo radiográfico, 42% passaram por punção liquórica e 36% deles não receberam qualquer tipo de intervenção. Nota-se, assim, que a qualidade do pré-natal recebido pela gestante não é suficiente para garantir o controle da sífilis congênita e o alcance da meta de incidência da doença.
Resumo:
OBJETIVO: Analisar os efeitos da ingestão crônica de álcool sobre o nervo óptico em um modelo murino adulto. MÉTODOS: Doze ratos machos da raça Wistar, de 30 dias de idade, foram divididos por sorteio em 2 grupos experimentais: tratado (TG), com 8 animais, alimentados com ração-padrão para roedores de laboratório e uma mistura de água de torneira e etanol ad libitum; controle (CG), com 4 animais, alimentados com a mesma ração e água de torneira pura ad libitum. Após 40 semanas todos os ratos foram sacrificados, sendo os nervos ópticos de ambos os olhos preparados para microscopia óptica e eletrônica. A área de secção transversal de cada nervo a aumento de 500´, assim como número de fibras axonais dentro de 5 campos aleatoriamente selecionados a aumento de 2000´ foram medidos com auxílio de digitalizador de imagens acoplado ao microscópio óptico. Foram realizadas fotomicrografias de 10 campos aleatoriamente selecionados de cada nervo (5 centrais e 5 periféricos) a aumento de 4200´ em microscópio eletrônico de transmissão. RESULTADOS: A análise morfométrica não mostrou diferenças estatisticamente significativas entre os 2 grupos estudados. em contraste com o CG, o exame ultra-estrutural dos nervos ópticos do TG mostrou um intenso desarranjo das bainhas de mielina, que se tornaram espessadas, com separação de suas lamelas, apresentando, por vezes, degenerações interlamelares elétron-densas, além da presença de muitas organelas degeneradas. CONCLUSÃO: Os achados desse estudo mostram alterações ultra-estruturais no nervo óptico de ratos adultos após ingestão crônica de álcool, sem modificações morfométricas significativas.