45 resultados para Superprotonic solid acid

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The babassu (Orbignya phalerata) is a native tree found in northern Brazil. Extracts of the babassu coconut have been widely used in industry. Babassu flour has about 60% starch, thus, besides nourishment it can be used as an alternative biofuel source. However, the properties of this starch lack of study and understanding. The main purpose of this study was to investigate the thermal behavior of raw babassu flour and its solid hydrolyzed fraction. The analyses were carried out using SHIMADZU DSC and TG thermic analyzers. The results demonstrated a reduction in thermal stability of the solid hydrolyzed fraction compared to raw matter. The kinetic parameters were investigated using non-isothermal methods and the parameters obtained for its decomposition process were an E(a) of 166.86 kJ mol(-1) and a frequency factor (beta) of 6.283 x 1014 min(-1); this was determined to be a first order reaction (n = 1). (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The electrochemical redox behavior of usnic acid, mainly known for its antibiotic activity, has been investigated using cyclic, differential pulse and square wave voltammetry in aqueous electrolyte. These studies were carried out by solid state voltammetry with the solid mechanically attached on the surface of a glassy carbon electrode and at different pH values. Usnic acid did not present any reduction reaction. The pH-dependent electrochemical oxidation occurs in three steps, one electron and one proton irreversible processes, assigned to each of the hydroxyl groups in the molecule. Adsorption of the non-electroactive oxidation product was also observed, blocking the electrode surface. An oxidation mechanism was proposed and electroanalytical methodology was developed to determine usnic acid.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

O ácido 2-metoxicinamalpirúvico (2-MeO-HCP) foi sintetizado e caracterizado por ressonância magnética nuclear (¹H and 13C NMR), espectrometria de massas (MS), espectroscopia na região do infravermelho (FTIR) e calorimetria exploratória diferencial (DSC). A técnica DSC foi usada para determinação da pureza do composto e as principais bandas de absorção na região do infravermelho foram atribuídas utilizando-se o programa GaussView 3.0.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A simultaneous method for the trace determination of acidic, neutral herbicides and their transformation products in estuarine waters has been developed through an on-line solid-phase extraction method followed by liquid chromatography with diode array and mass spectrometric detection. An atmospheric pressure chemical ionization (APCI) interface was used in the negative ionization mode after optimization of the main APCI parameters. Limits of detection ranged from 0.1 to 0.02 ng/ml for 50 mi of acidified estuarine waters preconcentrated into polymeric precolumns and using time-scheduled selected ion monitoring mode. Two degradation products of the acidic herbicides (4-chloro-2-methylphenol and 2,4-dichlorophenol) did not show good signal response using APCI-MS at the concentration studied due to the higher fragmentor voltage needed for their determination For molinate and the major degradation product of propanil, 3,4-dichloroaniline, positive ion mode was needed for APCI-MS detection. The proposed method was applied to the determination of herbicides in drainage waters from rice fields of the Delta del Ebro (Spain). During the S-month monitoring of the herbicides, 8-hydroxybentazone and 4-chloro-2-methylphenoxyacetic acid were successively found in those samples. (C) 2000 Elsevier B.V. B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

AgSIE was used for the direct analysis of folic acid (FA), with a detection limit and lower level of quantitation of 6.8 x10-10 mol L-1 and 2.3 x 10 8 mol L-1. The analysis in fresh and processed fruits was done without any sample pretreatment. In strawberry and acerola juices, FA concentration level values were below the method detection limit. FA was detectable in peach (77.7 0.4 mg L-1 and 64.4 0.5 mgL-1), Persian lime (45.4 0.7 mg L-1), pineapple Hawaii (66.2 0.4 mgL-1), pear pineapple (35.3 0.6 mgL-1), cashew (54.4 0.5 mgL-1) , passion fruit (73.2 0.3 mgL-1), and apple (84.4 0.5 mg L-1 ).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Solid state chelates of general formula H-2[M(EDTA)] . nH2O, where M is Co, Ni, Cu or Zn, and EDTA is ethylenediaminetetraacetate, were prepared. Thermogravimetry-derivative thermogravimetry (TG-DTG), differential thermal analysis (DTA) and complexometry were used to characterize and to study the thermal stability and thermal decomposition of these compounds.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Solid state chelates of general formula H[Ln(EDTA)] · nH2O (Ln = trivalent lanthanide (except for promethium) or yttrium; EDTA = ethylenediaminetetraacetate) were prepared. Thermogravimetry, differential thermal analysis. X-ray diffraction and complexometry were used to characterize and study the thermal stability and thermal decomposition of these compounds. © 1993.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The layer-by-layer technique was exploited to immobilize the enzyme uricase onto indium tin oxide substrates coated with a layer of Prussian Blue. Uricase layers were alternated with either poly(ethylene imine) or poly(diallyidimethylammoniumchloride), and the resulting films were used as amperometric biosensors for uric acid. Biosensors with optimum perfomance had a limit of detection of 0.15 mu A mu mol 1(-1) cm(-2) with a linear response between 0.1 and 0.6 mu M of uric acid, which is sufficient for use in clinical tests. Bioactivity was preserved for weeks, and there was negligible influence from interferents, as detection was carried out at 0.0 V vs saturated calomel electrode.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Solid paraffin-based carbon paste electrodes modified with 2-aminothiazole organofunctionalized silica have been applied to the anodic stripping determination of copper ions in ethanol fuel samples without any sample treatment. The proposed method comprised four steps: (1) copper ions preconcentration at open circuit potential directly in the ethanol fuel sample; (2) exchange of the solution and immediate cathodic reduction of the absorbate at controlled potential; (3) differential pulse anodic stripping voltammetry; (4) electrochemical surface regeneration by applying a positive potential in acid media. Factors affecting the preconcentration, reduction and stripping steps were investigated and the optimum conditions were employed to develop the analytical procedure. Using a preconcentration time of 20 min and reduction time of 120 s at -0.3 V versus Ag/AgCl(sat) a linear range from 7.5 x 10(-8) to 2.5 x 10(-6) mol L(-1) with detection limit of 3.1 x 10(-8) mol L(-1) was obtained. Interference studies have shown a decrease in the interference effect according to the sequence: Ni > Zn > Cd > Pb > Fe. However, the interference effects of these ions have not forbidden the application of the proposed method. Recovery values between 98.8 and 102.3% were obtained for synthetic samples spiked with known amounts of Cu(2+) and interfering metallic ions. The developed electrode was successfully applied to the determination of Cu(2+) in commercial ethanol fuel samples. The results were compared to those obtained by flame atomic absorption spectroscopy by using the F-test and t-test. Neither F-value nor t-value have exceeded the critical values at 95% confidence level, confirming that there are no significant differences between the results obtained by both methods. (c) 2006 Elsevier B.V. All rights reserved.