33 resultados para Subjective effort
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The purpose of this randomized study was to evaluate EMG spectral, subjective and cardiovascular recovery parameters after isometric lumbar extension contractions. Ten healthy women performed isometric lumbar extensions until exhaustion with 5%, 10%, 15% and 20% of maximal voluntary isometric contraction on 4 different days (random order). One baseline five second contraction was performed before the fatiguing task which was followed by eight submaximal five second extension contractions (until 20 minutes after the end of the fatiguing task) at the same intensity as the trial to evaluate muscle recovery. EMG (Median Frequency, Peak Power, Peak Power Frequency, Total Power and Zero-crossing Rate) and cardiovascular variables did not demonstrate any statistical difference between the 5-second contractions (p > 0.05) performed before and after the fatiguing task, showing a quick EMG recovery. However, the data analysis showed that the perceived effort variable had not recovered even 10 minutes after the fatigue contraction (p < 0.05). Our results represent a data basis for future comparisons and since subjective felling can affect performance, this study shows the importance of its analysis, since the subjective effort rate was not fully recovered after 10 minutes the end of the exhaustion contraction. © 2008 IOS Press. All rights reserved.
Resumo:
The application of ergonomics in product design is essential to its accessibility and usability. The development of manual devices should be based on ergonomic principles. Effort perception analysis is an essential approach to understand the physical and subjective aspects of the interface. The objective of the present study was to analyze the effort perception during a simulated task with different door handles by Portuguese subjects of both genders and different ages. This transversal study agreed with ethical aspects. 180 subjects of both genders pertaining to three age groups have participated. Five door handles with different shapes were evaluated. A subjective numeric rating scale of 5 levels was used to evaluate the effort. For statistical analysis it was applied the Friedman non-parametric test. The results have showed no significant differences of effort perception in door handles "A" and "B"; "A" and "D"; and "D" and "C". Door handle "E" presented the lowest values of all. In general, there's an inverse relationship between the results of biomechanical studies and the effort perception of the same task activity. This shows that door handles design influence directly these two variables and can interfere in the accessibility and usability of these kinds of products.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The study was conducted to analyze the histology of the ovaries of adults rats treated with steroids, and submitted or not to physical effort. The control group consisted of females submitted to physical effort and sedentary females, both of which received a physiological solution of 0.9% saline. Treated females, sedentary or not, received 6 mg/kg of body weight of nandrolone decanoate. The steroid and physiological solution were administered intraperitoneally, with a single injection per week for 4 consecutive weeks. The applied physical effort was swimming (20 minutes daily, 5 days/week, for the 4 weeks of treatment). Serial sections (5 mu m) of ovaries were prepared for histological evaluation and follicular score. The weight of ovaries and hypophysis, the number of antral and atretic follicles, and the area of corpus luteum were all affected by the steroids. In the ovaries of the control groups, well-developed corpus luteum was observed. In the treated groups, the cortical stroma was occupied by ovarian interstitial tissue. The females treated with steroids presented estral acyclicity. The use of nandrolone decanoate, whether associated with physical effort or not, affected the morphological pattern of the ovaries.
Resumo:
Objective: To evaluate the influence of alternative erasing times of DenOptix (R) (Dentsply/Gendex, Chicargo, IL) digital plates oil subjective image quality and the probability of double exposure image not Occurring.Methods: Human teeth were X-rayed with phosphor plates using tell different erasing times. Two observers evaluated the images for subjective Image quality (sharpness, brightness, contrast, enamel definition, dentin definition and dentin-enamal Junction definition) and for the presence or absence of double exposure image. Spearman's correlation analysis and ANOVA was performed to verify the existence ora linear association between the subjective image quality parameters and the alternative erasing times. A contingency table was constructed to evaluate the agreement among the observers, and a binominal logistic regression was performed to verify the correlation between the erasing time and the probability of double exposure image not occurring.Results: All 6 parameters or image quality were rated high by the examiners for the erasing times between 25 s and 130 s. The same erasing time range, from 25 to 130 s, was considered a safe erasing time interval, with no probability of a double exposure image Occurring.Conclusions: The alternative erasing times from 25 s to 130 s showed high quality and no probability of double image Occurrence. Thus, it is possible to reduce the operating time or the DenOptix (R) digital system Without jeopardizing the diagnostic task.Dentomaxillofacial Radiology (2010) 39, 23-27. doi: 10.1259/dmfr/49065239.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The population biology of Uca thayeri was studied in a subtropical mangrove in Ubatuba, State of São Paulo, Brazil. Two sampling techniques were used: transect sampling and catch-per-unit-effort. Size frequency distribution, sex-ratio, and reproductive period were analysed. For juvenile crabs (CW < 4.6 mm), the transect procedure was most efficient, while ovigerous females were most collected during the capture effort. Males were most numerous in the transect technique, while in the catch-per-unit-effort there was no difference between sexes. The species showed a different size frequency distribution for each sampling procedure. The reproduction of U. thayeri is seasonal, being more pronounced in the warmer months of the year. However, juveniles occurred all over the year, although more numerous in the colder months. The success of the species in reproductive activity and the constant colonization of the area can be attributed to the availability of food resources and differential occupation of the habitat by ovigerous females.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)