209 resultados para Sterilized impressions

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This in vitro study evaluated the dimensional accuracy of two impression techniques (tapered and splinted) with two stock trays (plastic and metal) for implant-supported prostheses. Materials and Methods: A master cast with four parallel abutment analogs and a passive framework were fabricated. Polyvinyl siloxane impression material was used for all impressions with two metal stock trays and two plastic stock trays (closed and open trays). Four groups (tapered plastic, splinted plastic, tapered metal, and splinted metal) and a control group (master cast) were tested (n = 5 for each group). After the framework was seated on each of the casts, one abutment screw was tightened, and the marginal gap between the abutment and framework on the other side was measured with a stereomicroscope. The measurements were analyzed with the Kruskal-Wallis one-way analysis of variance on ranks test followed by the Dunn method. Results: The mean values (+/- standard deviations) for the abutment/framework interface gaps were: master cast, 32 +/- 2 mu m; tapered metal, 44 +/- 10 mu m; splinted metal, 69 +/- 28 mu m; tapered plastic, 164 +/- 58 mu m; splinted plastic, 128 +/- 47 mu m. No significant difference was detected between the master cast, tapered metal, and splinted metal groups or between the tapered and splinted plastic groups. Conclusions: In this study, the rigidity of the metal stock tray ensured better results than the plastic stock tray for implant impressions with a high-viscosity impression material (putty). Statistically similar results were obtained using tapered impression copings and splinted squared impression copings. The tapered impression copings technique and splinted squared impression copings technique with a metal stock tray produced precise casts with no statistically significant difference in interface gaps compared to the master cast. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:544-550.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to investigate the level of microstrain that is exerted during polymerization of acrylic resins used for splinting during implant impressions. Material and Methods: Two acrylic resins (GC Pattern Resin, Duralay II) and square transfer coping splinting methods were evaluated by means of strain gauge analysis. Two implants were embedded in a polyurethane block, and the abutments were positioned. Sixty specimens were prepared using two square transfer Copings that were rigidly connected to each other using the acrylic resins. The specimens were randomly divided into three groups of 20 each for the splinting methods: Method 1 was a one-piece method; in method 2, the splint was separated and reconnected after 17 minutes; and in method 3, the splint was separated and reconnected after 24 hours. In each group, half the specimens were splinted with GC Pattern Resin and the other half were splinted with Duralay II. Three microstrain measurements were performed by four strain gauges placed on the upper surface of the polyurethane blocks at 5 hours after resin polymerization for all groups. The data were analyzed statistically. Results: Both resin type and splinting method significantly affected microstrain. interaction terms were also significant. Method 1 in combination with Duralay II produced significantly higher microstrain (1,962.1 mu epsilon) than the other methods with this material (method 2: 241.1 mu epsilon; method 3: 181.5 mu epsilon). No significant difference was found between splinting methods in combination with GC Pattern Resin (method 1: 173.8 mu epsilon; method 2: 112.6 mu epsilon; method 3: 105.4 mu epsilon). Conclusions: Because of the high microstrain generated, Duralay II should not be used for one-piece acrylic resin splinting, and separation and reconnection are suggested. For GC Pattern Resin, variations in splinting methods did not significantly affect the microstrain created. Int J Oral Maxillofac Implants 2012;27:341-345

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The accuracy of impressions that transfer the relationship of the implant to the metal framework of the prosthesis continues to be a problem. This study was designed to evaluate the accuracy of the transfer process under variable conditions with regard to implant analog angulations, impression materials, and techniques. Replicas (n = 60) of a metal matrix (control) containing four implants at 90°, 80°, 75°, and 65° in relation to the horizontal surface were obtained by using three impression techniques: T1 - indirect technique with conical copings in closed trays; T2 - direct technique with square copings in open trays; and T3 - square copings splinted with autopolymerizing acrylic resin; and four elastomers: P-polysulfide; I-polyether; A-addition silicone; and Z-condensation silicone. The values of the implant analog annulations were assessed by a profilometer to the nearest 0.017°, then submitted to analysis of variance for comparisons at significance of 5% (P < .05). For implant analog at 90°, the material A associated with T2 and material Z with T3 behaved differently (P < .05) from all groups. At 80°, all materials behaved differently (P < .01) with T1. At 75°, when T1 was associated, materials P and A showed similar behavior, as well as materials I and Z; however, P and A were different from I and Z (P < .01). When T3 was associated, all experimental groups behaved differently among them (P < .01). At 65°, the materials P and Z behaved differently (P < .01) from the control group with T1, T2, and T3; the materials I and A behaved differently from the control group (P < .01) when T1 and T2, respectively, were associated. The more perpendicular the implant analog annulation is in relation to the horizontal surface, the more accurate the impression. The best materials were material I and A and the most satisfactory technique was technique 3.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the effects of salinity in the growth and nitrogen fixation in leucaena. Plants were cultivated in Leonard pots containing clean and sterilized sand. The treatments were distributed in a completely randomized design, in a 3x3 factorial, with five replicates. The first factor corresponded to no inoculation and inoculation with Bradyrhizobium sp SEMIA 6070 and SEMIA 6153 strains. The second factor corresponded to NaCl concentrations: 0, 25 and 50 mol m(-3). Were analyzed the height and dry matter accumulation, the number of nodules and nitrogen in plants. The inoculation of plants with the strain SEMIA 6070 provided higher growth and greater nitrogen accumulation in plants thar were not subject to salinity. Nodulation was not affected by salinity. Inoculation with SEMIA 6153 strain provided greater tolerance to salinity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avaliou-se o ganho de peso de novilhas mestiças, 1/4 Simental e 3/4 Nelore, empregando-se o método experimental de esterilização, que consiste na introdução intrauterina de esferas inoxidáveis. Foram utilizadas 100 novilhas nulíparas, destinadas ao abate, com idades entre 12 e 24 meses e com média de peso de 275kg. Todos os animais receberam o mesmo manejo alimentar, em sistema de pastejo em Brachiaria brizantha, com água e sal mineral ad libitum, e pesagens a intervalos de 28 dias, obedecido o jejum prévio de 16 horas. Os animais foram distribuídos aleatoriamente em quatro grupos (G) experimentais: G1 - composto por 25 novilhas testemunhas; G2 - por 25 novilhas esterilizadas e aplicação de um modificador orgânico; G3 - por 25 novilhas esterilizadas; e G4 - por 25 novilhas não esterilizadas e aplicação de um modificador orgânico. Foram introduzidas 12 esferas de aço inoxidável, previamente esterilizadas, no útero de cada novilha. Houve maior ganho de peso total e diário entre os animais do G2, 140,50kg e 0,578g/dia vs 108,58kg e 0,447g/dia (G1), 103,73kg e 0,427g/dia (G3), 102,68kg e 0,423g/dia (G4), respectivamente. Esta técnica pode ser recomendada aos criadores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avaliou-se a patogenicidade do isolado IBCB 473 de Verticillium lecanii no pulgão-do-pinus Cinara atlantica (Hemiptera, Aphididae), inseto-praga em plantios de Pinus spp. O delineamento experimental utilizado foi o inteiramente casualizado, com cinco repetições por tratamento e cada repetição constituída de uma placa de Petri (9 cm de diâmetro) contendo 10 ninfas. Foram testadas suspensões de inóculo nas concentrações de 1,0 ' 10(6); 0,5 ' 10(7); 1,0 ' 10(7); 0,5 ' 10(8); e 1,0 ' 10(8) conídios/mL, pulverizando-se 1 mL sobre as ninfas. Como tratamento-testemunha, utilizou-se água esterilizada. As placas de Petri foram mantidas em câmara climatizada a 25 ± 1 °C, 70 ± 10% de UR e fotofase de 12 horas. As avaliações foram realizadas diariamente, anotando-se a mortalidade dos indivíduos de cada tratamento. A dose mais eficiente foi de 1,0 x 10(8) conídios/mL, causando mortalidade de 86,0% após cinco dias da pulverização. Os valores de TL50 das concentrações utilizadas foram de 5,82; 5,24; 4,60; 4,34; e 3,83 dias, respectivamente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A superfície interna das bisnagas fabricadas com alumínio não revestido e revestido com resina epóxi, utilizadas para acondicionar cremes, pomadas, géis, etc., foram avaliadas quimicamente e por métodos microbiológicos correlacionados com a aderência de microrganismos. A prova da porosidade e da resistência à remoção da resina foi observada por meio do microscópio eletrônico de varredura (Topcon FM300) e estereoscópio Leica (MZ12) acoplado a Sistema de Digitalização de Imagens. Para avaliar a ação dos microrganismos foram utilizados corpos-de-prova esterilizados (discos de 10mm de diâmetro), imersos em caldo Mueller Hinton (Difco) e colocados em tubos de polipropileno com tampa de rosca (Corning). Foram inoculados tubos com meio de cultura para cada uma das suspensões bacterianas (10(9)UFC/mL) de Streptococcus agalactiae, Staphylococcus aureus, Acinetobacter lwoffii e Candida albicans, incubados a 37°C, sob agitação constante durante 12 dias. O meio de cultura era trocado a cada 3 dias. Após esse período, os corpos-de prova foram removidos, processados e observados em microscópio eletrônico de varredura JEOL-JSM (T330A). A observação por meio do microscopio eletrônico de varredura mostrou a aderência e a formação de biofilme sobre a superfície de alumínio não revestido e revestido com resina epóxi.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ensaios foram conduzidos, em casa de vegetação, com solos de pastagem degradada reflorestada e cerrado preservado (controle) visando avaliar a contribuição de fungos micorrízicos arbusculares (FMA) autóctones no crescimento de mutambo (Guazuma ulmifolia Lamb.). As mudas foram transplantadas para sacos de plástico (2 kg) com substratos esterilizados na proporção 4:1 (solo:areia), e o tratamento inoculado recebeu 300 esporos de FMA por saco. A inoculação não proporcionou aumento significativo na produção da matéria seca da parte aérea, matéria fresca das raízes e altura da planta, sugerindo que a G. ulmifolia não é responsiva à micorrização.