268 resultados para Scared Straight
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Purpose: The present study was designed to analyze strain distributions caused by varying the fixture-abutment design and fixture alignment.Materials and Methods: Three implants of external, internal hexagon, and Morse taper were embedded in the center of each polyurethane block in straight placement and offset placement. Four strain gauges (SGs) were bonded on the surface of polyurethane block, which was designated SG1 placed mesially adjacent to implant A, SG2 and SG3 were placed mesially and distally adjacent to the implant B and SG4 was placed distally adjacent to the implant C. The 30 superstructures' occlusal screws were tightened onto the Microunit abutments with a torque of 10 N cm using the manufacturers' manual torque-controlling device.Results: There were statistically significant differences in prosthetic connection (P value = 0.0074 < 0.5). There were no statistically significant differences in placement configuration/alignment (P value = 0.7812 > 0.5).Conclusion: The results showed fundamental differences in both conditions. There was no evidence that there was any advantage to offset implant placement in reducing the strain around implants. The results also revealed that the internal hexagon and Morse taper joints did not reduce the microstrain around implants. (Implant Dent 2011; 20:e24-e32)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The aim of this in vitro study was to quantify strain development during axial and nonaxial loading using strain gauge analysis for three-element implant-supported FPDs, varying the arrangement of implants: straight line (L) and offset (O). Materials and Methods: Three Morse taper implants arranged in a straight line and three implants arranged in an offset configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, applying a 20 Ncm torque. Plastic copings were screwed onto the abutments, which received standard wax patterns cast in Co-Cr alloy (n = 10). Four strain gauges were bonded onto the surface of each block tangential to the implants. The occlusal screws of the superstructure were tightened onto microunit abutments using 10 Ncm and then axial and nonaxial loading of 30 Kg was applied for 10 seconds on the center of each implant and at 1 and 2 mm from the implants, totaling nine load application points. The microdeformations determined at the nine points were recorded by four strain gauges, and the same procedure was performed for all of the frameworks. Three loadings were made per load application point. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (mu). The data were analyzed statistically by two-way ANOVA and Tukey's test (p < 0.05). Results: The configuration factor was statistically significant (p= 0.0004), but the load factor (p= 0.2420) and the interaction between the two factors were not significant (p= 0.5494). Tukey's test revealed differences between axial offset (mu) (183.2 +/- 93.64) and axial straight line (285.3 +/- 61.04) and differences between nonaxial 1 mm offset (201.0 +/- 50.24) and nonaxial 1 mm straight line (315.8 +/- 59.28). Conclusion: There was evidence that offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or nonaxial, did not have an influence until 2 mm.
Resumo:
An approach using straight lines as features to solve the photogrammetric space resection problem is presented. An explicit mathematical model relating straight lines, in both object and image space, is used. Based on this model, Kalman Filtering is applied to solve the space resection problem. The recursive property of the filter is used in an iterative process which uses the sequentially estimated camera location parameters to feedback to the feature extraction process in the image. This feedback process leads to a gradual reduction of the image space for feature searching, and consequently eliminates the bottleneck due to the high computational cost of the image segmentation phase. It also enables feature extraction and the determination of feature correspondence in image and object space in an automatic way, i.e., without operator interference. Results obtained from simulated and real data show that highly accurate space resection parameters are obtained as well as a progressive processing time reduction. The obtained accuracy, the automatic correspondence process, and the short related processing time show that the proposed approach can be used in many real-time machine vision systems, making possible the implementation of applications not feasible until now.
Resumo:
This work determined toxicity and attractiveness of straight-chain fatty acids (C 5 to C 12) to Atta sexdens rubropilosa (Forel) workers. The effect to the symbiotic fungus, Leucoagaricus gongylophorus (Singer) Möller, was also tested with the fatty acids C 6 to C 12. A strong mortality of leaf-cutting ants that were fed with an artificial diet containing fatty acids C to C at concentrations above 1.0 mg.ml -1 was observed. Rice flakes impregnated with solutions of these fatty acids were repellent to leaf-cutting ants. Contact experiments showed that treatments with C 6 and C 7 at concentration of 100 mg.ml -1 significantly reduced the survival rate of leaf-cutting ants. The fatty acids C 8 to C 11 were toxic to leaf-cutting ants when topically tested at concentration of 200 mg.ml -1. In relation to the fungus' bioassays, the fatty acids C 6 to C 12 at concentration of 0.1 mg.ml -1 inhibited 100% of the fungal development. Although when the concentration was reduced by half no inhibition effects were observed. The results showed that straight-chain fatty acids have desirable properties for controlling leaf-cutting ants since they directly interfere with both organisms of the symbiotic relationship. The potential of fatty acids as well as ways to control leaf-cutting ants with these compounds are discussed in this article.
Resumo:
The gravitational properties of a straight cosmic string are studied in the linear approximation of higher-derivative gravity. These properties are shown to be very different from those found using linearized Einstein gravity: there exists a short range gravitational (anti-gravitational) force in the nonrelativistic limit; in addition, the deflection angle of a light ray moving in a plane orthogonal to the string depends on the impact parameter. © 2008 World Scientific Publishing Company.
Resumo:
This study compared the effect of the treatment protocol for correcting Class Il malocclusion using the Herbst appliance followed by full fixed Straigh-wire mechanics, in two populations, one Brazilian and one of North American origin As a untreated control sample the data from the University of Michigan Elementary and Secondary School Growth Study (UMGS) was used. Our sample was composed of 12 males and 12 females, with initial mean age of 12 years 7 months and final mean ages of 15 years and 3 months. The Michigan patients comprised 21 females and 7 males, with an initial mean age of 11 years and 9 months and final mean age of 14 years and 4 months. The control sample was paired in number, sex and age to the treated Michigan sample. ln both treated groups, lateral cephalometric radiographs were obtained before the Herbst appliance was cemented and at the end of the fixed appliance phase, The first comparison involved the Brazil group and the untreated controls, which demonstrated that the association of the Herbst appliance followed by fixed Straight-wire appliances provoked positive effects on the dentofacial complex, improving pre-existing maxillo-mandibular relationships, besides increasing dentoalveolar compensations which contributed to correct the malocclusion. The second comparison, involved the Brazl1ian and North-American patients treated with the same protocol. Although the pre-treatment comparison showed that the two groups were not similar in all aspects, they presented almost identical therapeutic modifications, which indicate that the effect of' treatment was very similar. These results point out that, in Class ll treatment, the combination of Herbst/Straight-wire mechanics produce consistent and systematic effects, correcting or minimizing possible skeletal imbalances
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
PURPOSE: In view of reports in the literature on the benefits achieved with the use of platform switching, described as the use of an implant with a larger diameter than the abutment diameter, the goal being to prevent the (previously) normal bone loss down to the first thread that occurs around most implants, thus enhancing soft tissue aesthetics and stability and the need for implant inclination due to bone anatomy in some cases, the aim of this study was to evaluate bone stress distribution on peri-implant bone, by using three-dimensional finite element analysis to simulate the influence of implants with different abutment angulations (0 and 15 degrees) in platform switching. METHODS: Four mathematical models of an implant-supported central incisor were created with varying abutment angulations: straight abutment (S1 and S2) and angulated abutment at 15 degrees (A1 and A2), submitted to 2 loading conditions (100 N): S1 and A1-oblique loading (45 degrees) and S2 and A2-axial loading, parallel to the long axis of the implant. Maximum (σmax) and minimum (σmin) principal stress values were obtained for cortical and trabecular bone. RESULTS: Models S1 and A1 showed higher σmax in cortical and trabecular bone when compared with S2 and A2. The highest σmax values (in MPa) in the cortical bone were found in S1 (28.5), followed by A1 (25.7), S2 (11.6), and A2 (5.15). For the trabecular bone, the highest σmax values were found in S1 (7.53), followed by A1 (2.87), S2 (2.85), and A2 (1.47). CONCLUSIONS: Implants with straight abutments generated the highest stress values in bone. In addition, this effect was potentiated when the load was applied obliquely.
Resumo:
A lagarta-do-cartucho, Spodoptera frugiperda (J.E. Smith), é uma das principais pragas do milho nas Américas. O estudo de sua distribuição espacial é fundamental para a utilização de estratégias de controle, otimização de técnicas de amostragens, determinação de danos econômicos e incorporação de um programa de agricultura de precisão. em uma área cultivada com milho foram realizadas amostragens com intervalo semanal, correspondendo ao estádio vegetativo que compreende desde a germinação até o pendoamento. Foram amostradas 10 plantas ao acaso por parcela, no total de 2000 plantas em cada amostragem. A produtividade foi obtida através da colheita de todas as parcelas que eram pesadas separadamente no campo e em cada parcela foram coletadas 15 espigas aleatoriamente para estimar o comprimento e o diâmetro médio. As análises espaciais, utilizando geoestatística, mostraram que o modelo esférico apresentou o melhor ajuste às lagartas pequenas. À medida que as lagartas foram se desenvolvendo sua distribuição foi tornando aleatória, representada por um modelo ajustado por uma reta, não tendo sido detectado nenhum tipo de dependência espacial nos pontos de amostragem. A produtividade e o diâmetro e comprimento da espiga foram descritos por modelos esféricos, indicando uma variabilidade espacial nos parâmetros de produtividade na área cultivada. A geoestatística mostrou-se promissora para a aplicação de métodos precisos no controle integrado de pragas.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)