30 resultados para Plastic hinge

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Summary In this work the structural dependence of plastic rotation capacity in RC beams is evaluated using the Finite Element Method. The objective is to achieve a better understanding of the non-linear behavior of reinforced concrete members and perform extensive parameter studies, using a rational model developed by Bigaj [1] to analyze the phenomenon of plastic rotation capacity in reinforced concrete members. It is assumed that only bending failure is relevant due to sufficient member resistance against shear and torsion. The paper begins with the physical and theoretical background of the phenomenon of plastic hinge development in RC structures. Special emphasis is laid on the issue of structural dependence of deformation capacity of plastic hinges in RC members. Member size dependence and influence of properties of construction materials were emphasized as well. The essential components of the Bigajs model for calculating the plastic rotation capacity are discussed. The behaviour of the plastic hinge is analysed taking into account the strain localisation in the damage zones of the hinge region. The Fictitious Crack Model (FCM) and the Compressive Damage Zone Model (CDZ) are adopted in a Fracture Mechanics approach to model the behaviour of concrete in tension and compression, respectively. The approach is implemented in FEMOOP, a FEM in-house solver under development, and applied to evaluate ductility in 2D beams. The models were generated with GiD, a pre-processor and post-processor developed by CIMNE, and analyzed with the capabilities implemented in FEMOOP. © Universitat Politècnica de Catalunya, Barcelona, España 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo examinou as respostas de estresse de juvenis de pirarucu transportados em sistema fechado. Pirarucu (Arapaima gigas) é um peixe nativo da bacia Amazônica, da família Osteoglossidae que possui respiração aérea obrigatória. Foi realizado um transporte de curta duração (6 h) em sacos de polietileno inflados com ar atmosférico (grupo ar) ou com oxigênio puro (grupo oxi). O oxigênio dissolvido foi o único parâmetro de qualidade da água que apresentou diferença estatística entre os grupos, e como esperado, o oxigênio estava supersaturado para o grupo oxi. Não houve mortalidade após o transporte em ambos os grupos. Os peixes se alimentaram 36 h após o transporte e apresentaram um consumo de ração habitual após 72 h. As respostas fisiológicas foram semelhantes nos dois grupos. O cortisol não apresentou mudança significativa durante o período de amostragem. Ao contrário da maioria das espécies, os valores de cortisol se apresentaram inalterados nos dois grupos durante a amostragem, enquanto a glicose teve um aumento significativo até 12 h após o transporte. Os resultados mostram que o transporte de pirarucu em sacos de polietileno pode ser realizado com ar atmosférico ou oxigênio puro, uma vez que as respostas de estresse, a qualidade da água e o comportamento alimentar após 36 h foram similar entre os grupos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an experimental investigation of the characteristics of leak noise in plastic water-filled pipes. An experimental set-up was designed to identify the physical mechanisms of leak noise generation. Possible mechanisms include cavitation and turbulence. The experiments show that cavitation is not responsible for leak noise generation and clearly indicate that turbulence is the main mechanism, at least in the experiments conducted. An alternative experimental set-up was also designed to identify the characteristics of leak noise spectra and to investigate how the spectra are affected by the leak size and the leak flow velocity. A number of different hole sizes (leaks) starting from 1 mm diameter, increasing progressively every 0.5 mm until a size of 4 mm diameter were tested for different jet velocities and an empirical model that describes this behaviour is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A interação entre arte e ciência foi intensa durante o Renascimento, sofrendo declínio nos anos posteriores com retomada significativa no século XX, principalmente com o uso de técnicas de identificação, datação de obras de arte e o desenvolvimento de novos materiais. O relacionamento entre artes plásticas e Cirurgia da Mão mantêm-se intenso , sendo freqüente o uso de reproduções artísticas da mão nas ilustrações de textos científicos. Objetivando compreender o papel da mão nas artes plásticas, reproduções de obras de artes (esculturas e pinturas) representativas de vários estilos ou períodos da história da arte foram analisadas com enfoque no estudo das mãos. Detalhes anatômicos, relacionamento com outras estruturas do corpo humano, papel na composição e aspectos simbólicos das mãos foram estudados no contexto histórico e artístico de obras de arte do período paleolítico (pré-história) até o século XX. A representação da mão nas artes plásticas está diretamente relacionada ao estilo ou período da obra e à capacidade individual de interpretação e execução do artista.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present article describes the preparation and characterization A anionic Collagen gels obtained from porcine intestinal submucosa after 72 h of alkaline treatment and in the form of rhamsan composites to develop injectable biomaterials for plastic for construction. All materials were characterized by SDS/polyacrylamide gel electrophoresis, infrared spectroscopy, thermal stability, potentiometric titration, rheological properties, and fluidity tests. Biocompatibility was appraised after the injection of anionic collagen:rhamsan composites at 2.5% in 60 North Folk rabbits. Independently of processing, the Collagen's secondary structure was preserved in all cases, and after 72 h of hydrolysis the Collagen was characterized by a carboxyl group content of 346 :L 9, which, at physiological pH, corresponds to an increase of 106 17 negative charges, in comparison to native Collagen, due to the selective hydrolysis of asparagine and glutamine carboxyamide side chain. Rheological studies of composites at pH 7.4 in concentrations of 2, 4, and 6% (in proportions of 75:1 and 50:1) showed a viscoelastic behavior dependent on the frequency, which is independent of concentration and proportion. In both, the concentration of the storage modulus always predominated over the loss modulus (G' > G and delta < 45 degrees). The results from creep experiments confirmed this behavior and showed that anionic collagen:rhamsan composites at pH 7.4 in the proportion of 50:1 are less elastic and more susceptible to deformation in comparison to gels in the proportion of 75:1, independent of concentration. This was further confirmed by flow experiments, indicating that the necessary force for the extrusion of anionic collagen:rhamsan composites, in comparison to anionic Collagen, was significantly smaller and with a smooth flow. Biocompatibility studies showed that the tissue reaction of anionic collagen:rhamsan composites at 2.5% in the proportion of 75:1 was compatible with the application of these gels in plastic reconstruction. These results suggest that the association of Collagen with rhamsan may be a good alternative in the replacement of glutaraidehyde to stabilize the microfibril assembly of commercial Collagen gel preparations. (c) 2005 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This in vitro study evaluated the dimensional accuracy of two impression techniques (tapered and splinted) with two stock trays (plastic and metal) for implant-supported prostheses. Materials and Methods: A master cast with four parallel abutment analogs and a passive framework were fabricated. Polyvinyl siloxane impression material was used for all impressions with two metal stock trays and two plastic stock trays (closed and open trays). Four groups (tapered plastic, splinted plastic, tapered metal, and splinted metal) and a control group (master cast) were tested (n = 5 for each group). After the framework was seated on each of the casts, one abutment screw was tightened, and the marginal gap between the abutment and framework on the other side was measured with a stereomicroscope. The measurements were analyzed with the Kruskal-Wallis one-way analysis of variance on ranks test followed by the Dunn method. Results: The mean values (+/- standard deviations) for the abutment/framework interface gaps were: master cast, 32 +/- 2 mu m; tapered metal, 44 +/- 10 mu m; splinted metal, 69 +/- 28 mu m; tapered plastic, 164 +/- 58 mu m; splinted plastic, 128 +/- 47 mu m. No significant difference was detected between the master cast, tapered metal, and splinted metal groups or between the tapered and splinted plastic groups. Conclusions: In this study, the rigidity of the metal stock tray ensured better results than the plastic stock tray for implant impressions with a high-viscosity impression material (putty). Statistically similar results were obtained using tapered impression copings and splinted squared impression copings. The tapered impression copings technique and splinted squared impression copings technique with a metal stock tray produced precise casts with no statistically significant difference in interface gaps compared to the master cast. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:544-550.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bothropstoxin I(BthTX-I) from the venom of Bothrops jararacussu is a myotoxic phospholipase A2 (PLA2) homologue which, although catalytically inactive due to an Asp49-->Lys substitution, disrupts the integrity of lipid membranes by a Ca2+-independent mechanism, the crystal structures of two dimeric farms of BthLTX-I which diffract X-rays eo resolutions of 3.1 and 2.1 Angstrom have been determined, the monomers in both structures are related by an almost perfect twofold axis of rotation and the dimer interfaces are defined by contacts between the N-terminal alpha-helical regions and the tips of the beta-wings of partner monomers. Significant differences in the relative orientation of the monomers in the two crystal forms results in open and closed dimer conformations, Spectroscopic Investigations of BthTX-I in solution have correlated these conformational differences with changes in the intrinsic fluorescence emission of the single tryptophan residues located at the dimer interface, the possible relevance of this structural transition in the Ca2+-independent membrane damaging activity is discussed. (C) 1998 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a methodology for elastic-plastic fracture reliability analysis of plane and axisymmetric structures. The structural reliability analysis is accomplished by means of the FORM analytical method. The virtual crack extension technique based on a direct minimization of potencial energy is utililized for the calculation of the energy release rate. Results are presented to illustrate the performance of the adopted methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The elastic-plastic structural stability behaviour of arches is analysed in the present work.The application of the developed mathematical model, allows to determine the elastic-plastic equilibrium paths, looking for critical points, bifurcation or limit, along those paths, associated to the critical load, in case it comes to happen.The equilibrium paths in the elastic-plastic behaviour when compared with the paths in the linear elastic behaviour, may show that, due to influence of the material plasticity, modifications paths appear and consequently alterations in the values of its critical loads.