51 resultados para PIC 18F8722

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This monograph proposes the implementation of a low cost PID controller utilizing a PIC microcontroller, and its application in a positioning system previously controlled by a dedicated integrated circuit for a positioning system. Applying the closed-loop PID control, the system instability was reduced, and its response was smoother, eliminating vibrations and mechanical wear compared to its response with the dedicated integrated circuit, which has a very limited control action. The actuator of the system is a DC motor, whose speed is controlled by the Pulse Width Modulation (PWM) technique, using a Full-Bridge circuit, allowing the shift of direction of rotation. The utilized microcontroller was the PIC16F684, which has an enhanced PWM module, with its analog converters used as reference and position feedback. The positioning sensor is a multiturn potentiometer coupled to the motor axis by gears. The possibility of programming the PID coefficients in the microcontroller, as well as the adjustment of the sampling rate, allows the implemented system achieving high level of versatility

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Langmuir-Blodgett (LB) films from a ruthenium complex mer-[RuCl3 (dppb)(4-Mepy)] (dppb = PPh2 (CH2)(4)-PPh2; 4-Mepy = 4-methylpyridine), termed Ru-Pic, display a distinct color, which is different from the coloration exhibited by cast films or chloroform solutions. The solution and cast films are red, while the LB films are green-bluish. The manifestation of the blue color in the LB film finds its explanation in a unique absorption band at 690 nm, which is associated with the oxidation of the phosphine moieties. Fluorescence emission and absorption-reflection infrared spectroscopy measurements revealed the molecular organization in the LB films. In contrast, cast films showed a random distribution of complexes. Surface-enhanced Raman scattering was also used in an attempt to identify the main interactions in Ru-Pic.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent studies have demonstrated that sheath dynamics in plasma immersion ion implantation (PIII) is significantly affected by an external magnetic field, especially in the case when the magnetic field is parallel to the workpiece surface or intersects it at small angles. In this work we report the results from two-dimensional, particle-in-cell (PIC) computer simulations of magnetic field enhanced plasma immersion implantation system at different bias voltages. The simulations begin with initial low-density nitrogen plasma, which extends with uniform density through a grounded cylindrical chamber. Negative bias voltage is applied to a cylindrical target located on the axis of the vacuum chamber. An axial magnetic field is created by a solenoid installed inside the target holder. A set of simulations at a fixed magnetic field of 0.0025 T at the target surface is performed. Secondary electron emission from the target subjected to ion bombardment is also included. It is found that the plasma density around the cylindrical target increases because of intense background gas ionization by the electrons drifting in the crossed E x B fields. Suppression of the sheath expansion and increase of the implantation current density in front of the high-density plasma region are observed. The effect of target bias on the sheath dynamics and implantation current of the magnetic field enhanced PIII is discussed. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The behavior of plasma and sheath characteristics under the action of an applied magnetic field is important in many applications including plasma probes and material processing. Plasma immersion ion implantation (PIII) has been developed as a fast and efficient surface modification technique of complex shaped three-dimensional objects. The PIII process relies on the acceleration of ions across a high-voltage plasma sheath that develops around the target. Recent studies have shown that the sheath dynamics is significantly affected by an external magnetic field. In this work we describe a two-dimensional computer simulation of magnetic field enhanced plasma immersion implantation system. Negative bias voltage is applied to a cylindrical target located on the axis of a grounded cylindrical vacuum chamber filled with uniform nitrogen plasma. An axial magnetic field is created by a solenoid installed inside the cylindrical target. The computer code employs the Monte Carlo method for collision of electrons and neutrals in the plasma and a particle-in-cell (PIC) algorithm for simulating the movement of charged particles in the electromagnetic field. Secondary electron emission from the target subjected to ion bombardment is also included. It is found that a high-density plasma region is formed around the cylindrical target due to the intense background gas ionization by the magnetized electrons drifting in the crossed ExB fields. An increase of implantation current density in front of high density plasma region is observed. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estudou-se retrospectivamente a evolução clínica de dois pacientes, até sua falência cardíaca irreversível (FCI), submetidos à monitorização contínua da pressão intracraniana (PIC). O estudo detalhado desses traçados mostrou que, nos dois casos a PIC atingiu valores máximos 5 e 12 h antes de ocorrer diminuição na amplitude das ondas, observada 47 e 60 h pré-FCI. Essa diminução foi progressiva e tornou-se linear cerca de 30 h antes da FCI, em ambos os casos. O diagnóstico clínico de morte encefálica (ME) foi obtido 3 e 28 hs após a linearidade do traçado. Os autores sugerem que o diagnóstico de ME pode ser definido mais precocemente com o uso da monitorização da PIC desde que o paciente não esteja sob sedação, e salientam a necessidade de mais observações, em número maior de pacientes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estudaram-se possíveis alterações hemodinâmicas e intracranianas em cães submetidos à hemorragia aguda e anestesiados pelo isofluorano. Verificou-se também a influência do anestésico no mecanismo de auto-regulação cerebral. Utilizaram-se 20 cães adultos que foram induzidos à anestesia geral com isofluorano por máscara naso-oral a 3,5V% (volume %). Após a intubação orotraqueal, reajustou-se o vaporizador para 2,1V%. Induziu-se a hipovolemia retirando-se volume total de 35ml/kg de sangue. Avaliaram-se pressão intracraniana (PIC), temperaturas intracraniana (TIC) e corpórea (T), pressão de perfusão cerebral (PPC), pressões arteriais sistólica (PAS), diastólica (PAD) e média (PAM), freqüências cardíaca (FC) e respiratória (FR), índices cardíaco (IC) e sistólico (IS), pressão venosa central (PVC), pressão da artéria pulmonar (PAP), concentração de dióxido de carbono ao final da expiração (ETCO2) e saturação de oxihemoglobina (SpO2). Imediatamente após a hipovolemia, houve redução significativa da PIC, PPC, PAS, PAD, PAM, IC, IS e PAP. Após 10 minutos, houve aumento gradativo das médias, permanecendo neste patamar até o final do período experimental. Concluiu-se que a hemorragia aguda promoveu redução das variáveis hemodinâmicas, sendo possível verificar a ativação de mecanismos compensatórios. Além disso, houve redução da perfusão sangüínea e ativação do mecanismo de auto-regulação cerebral, conseqüentes à hipovolemia associada à anestesia com isofluorano.