34 resultados para PAC

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effects of fish oil acidity on the growth of pacu (Piaractus mesopotamicus) juveniles. Two hundred juveniles with 10.53±0.65 g of weight and 8.74±0.13 cm of total length, were distributed in a totally randomized design in 20, 0.15 m3 meshmade tanks placed in a 25 m3 holding tank. Extruded commercial diets sprayed with soybean oil (control) with acidity index of 0.24 and fish oil with acidity index of 1.48, 6.40 and 9.85 were used. The fish were fed four times a day until apparent satiety. Productive performance, centesimal composition and blood biochemistry were analysed. At the end of the feeding period none of the analyzed parameters was affected by the use of acidified fish oil. Therefore, fish oil may be supplied to the pacu juveniles regardless of their pH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Serviço Social - FCHS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: desenvolver o modelo experimental de hipertensão tipo Goldblatt I (1 rim - 1 clipe), em ratas, para estudar a interação entre hipertensão e prenhez. Métodos: o experimento foi dividido em 5 períodos: adaptação (2 semanas), cirúrgico (1 semana), desenvolvimento da hipertensão (6 semanas), acasalamento e estabilização da pressão arterial (6 semanas) e prenhez (3 semanas). Foram utilizadas 82 ratas virgens da raça Wistar, pesando entre 180-240 gramas e com idade entre 3 e 4 meses. As ratas foram sorteadas para compor os 4 grupos experimentais (controle, manipulação, nefrectomia e hipertensão) e estudadas em 15 momentos distintos (M1 a M15). A hipertensão foi induzida experimentalmente pela técnica de Goldblatt I (1 rim, 1 clipe), que consiste na constrição da artéria renal esquerda e nefrectomia contralateral. Posteriormente, foram realizadas medidas periódicas da pressão arterial pelo método da pletismografia de cauda (PAC). Resultados: os animais sem tratamento cirúrgico (controle) e com manipulação não apresentaram alterações na PAC durante o experimento. A nefrectomia determinou discreta elevação da PAC. Nos grupos de ratas prenhes, observou-se tendência a discreta diminuição da PAC, que se acentuou no final da prenhez. Conclusões: o modelo experimental foi adequado para o objetivo de nosso estudo, pois permitiu a obtenção de animais hipertensos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although the use of periodontal dressings is currently limited, there are some indications for their use. Selection of any material that will have direct contact with live tissues, such as periodontal dressings, should be careful in order to allow surgical wound healing. The aim of this study was to evaluate the intensity of inflammatory response and bone formation in tooth sockets of rats after implantation of three periodontal dressings. After removal of the right maxillary incisors of 84 male rats, each tooth socket received implantation of a polyethylene tube, 63 of which were filled with non-eugenol periodontal dressing and the remaining 21 tubes remained empty (control group). Histological evaluation assessed the intensity of inflammatory response and presence and location of bone tissue formation at postoperative periods of 7, 14 and 28 days. Statistical analysis was performed by the Kruskal-Wallis test at 5% significance level. Regarding the inflammatory infiltrate, at 28 days, there was statistically significant difference between one of periodontal dressings and control group (p < 0.05). Analysis of postoperative periods, showed that the control group presented statistically significant reduction in the inflammatory infiltrate comparing the 14- and 28-day periods (p < 0.05). Regarding bone tissue formation, there was difference in control group between the 7- and 28-day periods (p < 0.05). Within the experimental conditions, it may be concluded that no differences were found in the inflammatory response among the groups at 7 and 14 days and that Voco pac (TM) dressing induced a more intensive inflammatory reaction at 28 days.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the influence of light-curing units (LCUs) on Knoop microhardness (KHN) of different composite resins formulations. Four LCUs, one Quartz-Tungsten-Halogen (QTH) for 20 s, one Argon-Ion-Laser (AL) for 10 s, one Plasma-Arc-Curing (PAC) for 9 s, and one Light-Emitting-Diode (LED) for 20 s, and three composite resins, nanofill and easy cure (Filtek (TM) Supreme), microhybrid and medium cure (Herculite XRV), and microfill and difficult cure (Heliomolar) were used. Discs (4 x 2 mm(2)) of each composite resin were divided in 12 Groups and KHN was measured at the top (T) and bottom (B) surfaces. Data were analyzed using two-way ANOVA and Tukey's test (p < 0.05). Top presented significantly higher KHN than bottom surface for all composite resins and LCUs tested. Statistical significant differences were observed among the LCUs. At the bottom surface QTH and LED presented higher KHN than PAC and LA. However, at the top surface PAC and LA presented similar results than QTH for nanofill and microhybrid composite resins. Different LCUs play an important effect on Knoop microhardness and the composite resin formulations were significant factor on the photosensitivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Compact Muon Solenoid (CMS) detector is described. The detector operates at the Large Hadron Collider (LHC) at CERN. It was conceived to study proton-proton (and lead-lead) collisions at a centre-of-mass energy of 14 TeV (5.5 TeV nucleon-nucleon) and at luminosities up to 10(34)cm(-2)s(-1) (10(27)cm(-2)s(-1)). At the core of the CMS detector sits a high-magnetic-field and large-bore superconducting solenoid surrounding an all-silicon pixel and strip tracker, a lead-tungstate scintillating-crystals electromagnetic calorimeter, and a brass-scintillator sampling hadron calorimeter. The iron yoke of the flux-return is instrumented with four stations of muon detectors covering most of the 4 pi solid angle. Forward sampling calorimeters extend the pseudo-rapidity coverage to high values (vertical bar eta vertical bar <= 5) assuring very good hermeticity. The overall dimensions of the CMS detector are a length of 21.6 m, a diameter of 14.6 m and a total weight of 12500 t.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents and describes in detail the pressure profile in a conical tube with the unavoidable steady-state outgassing, plus a transient gas source, like, for instance, in an accelerator, when particles from the beam hit the walls. Mathematical and physical formulations are given and detailed; specific conductance, specific throughput and a detailed discussion about the boundary conditions are presented. These concepts and approach are applied to usual realistic cases, such as conical tubes, with typical laboratory dimensions. © 2005 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the Knoop hardness of a dual-cured resin cement (Rely-X ARC) activated solely by chemical reaction (control group) or by chemical / physical mode, light-cured through a 1.5 mm thick ceramic (HeraCeram) or composite (Artglass) disc. Light curing was carried out using conventional halogen light (XL2500) for 40 s (QTH); light emitting diodes (Ultrablue Is) for 40 s (LED); and Xenon plasma arc (Apollo 95E) for 3 s (PAC). Bovine incisors had their buccal face flattened and hybridized. On this surface a rubber mold (5 mm in diameter and 1 mm in height) was bulk filled with the resin cement. A polyester strip was seated for direct light curing or through the discs of veneering materials. After dry storage in the dark (24 h 37°C), the samples (n = 5) were sectioned for hardness (KHN) measurements, taken in a microhardness tester (50 gF load 15 s). The data were statistically analyzed by ANOVA and Tukey's test (α = 0.05). The cement presented higher Knoop hardness values with Artglass for QTH and LED, compared to HeraCeram. The control group and the PAC/Artglass group showed lower hardness values compared to the groups light-cured with QTH and LED. PAC/HeraCeram resulted in the worst combination for cement hardness values. © 2009 Sociedade Brasileira de Pesquisa Odontológica.