20 resultados para Optical measurement.
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The class of piezoelectric actuators considered in this paper consists of a multi-flexible structure actuated by two or more piezoceramic devices that must generate different output displacements and forces at different specified points of the domain and in different directions. The devices were modeled by finite element using the software ANSYS and the topology optimization method. The following XY actuators were build to achieve maximum displacement in the X and Y directions with a minimum crosstalk between them. The actuator prototypes are composed of an aluminum structure, manufactured by using a wire Electrical Discharge Machining, which are bonded to rectangular PZT5A piezoceramic blocks by using epoxy resin. Multi-actuator piezoelectric device displacements can be measured by using optical interferometry, since it allows dynamic measurements in the kHz range, which is of the order of the first resonance frequency of these piezomechanisms. A Michelson-type interferometer, with a He-Ne laser source, is used to measure the displacement amplitudes in nanometric range. A new optical phase demodulation technique is applied, based on the properties of the triangular waveform drive voltage applied to the XY piezoelectric nanopositioner. This is a low-phase-modulation-depth-like technique that allows the rapid interferometer auto-calibration. The measurements were performed at 100 Hz frequency, and revealed that the device is linear voltage range utilized in this work. The ratio between the generated and coupled output displacements and the drive voltages is equal to 10.97 nm/V and 1.76 nm/V, respectively, which corresponds to a 16% coupling rate. © 2010 IEEE.
Resumo:
In this work, doped AlGaAs/GaAs parabolic quantum wells (PQW) with different well widths (from 1000 angstrom up to 3000 angstrom) were investigated by means of photoluminescence (PL) measurements. In order to achieve the 2DEG inside the PQW Si delta doping is placed at both side of the well. We have observed that the thickness of this space layer plays a major rule on the characteristics of the 2DEG. It has to be thicker enough to prevent any diffusions of Si to the well and thin enough to allow electrons migration inside the well. From PL measurement, we have observed beside the intra well transitions, indirect transitions involving still trapped electron on the delta doping and holes inside the PQW. For the thinness sample, we have measured a well defined PL peak at low energy side of the GaAs bulk emission. With the increasing of the well thickness this peak intensity decreases and for the thickest sample it almost disappears. Our theoretical calculation indicated that carriers (electron and holes) are more placed at the center of the PQW. In this way, when the well thickness increases the distance between electrons on the delta doping and holes on the well also increases, it decreases the probability of occurrence of these indirect optical transitions. (C) 2012 Published by Elsevier B.V. Selection and/or peer-review under responsibility of Universidade Federal de Juiz de Fora, Brazil.
Resumo:
Em 12 fêmeas e 12 machos da raça Puro Sangue Inglês com idade média de 12 meses, avaliou-se os valores normais da densidade mineral óssea do carpo acessório em milímetros de alumínio (mmAl) até o momento do fechamento completo da epífise distal do rádio, por meio do método de densitometria óptica em imagens radiográficas. A avaliação foi realizada por meio de um programa computacional (software) especialmente desenvolvido para medida de densidade óptica em filmes de raios-X, o qual contém a imagem radiográfica do osso carpo acessório, região de partes moles adjacente ao carpo acessório e os degraus de uma escala de alumínio (phatom), que permitiu a medida de densidade mineral óssea, sendo esta a média aritmética da região de interesse determinada no osso carpo acessório correspondente ao valor em milímetros da escala. Os valores da densidade mineral óssea em mmAl do acessório do carpo em função da idade não apresentaram diferenças entre os sexos (p=0,86) permitindo que uma equação de reta fosse ajustada para ambos os sexos (densidade mineral óssea (DMO) mmAl = 3.109 + 0,056 x idade em meses), na faixa etária estudada.
Resumo:
A significant part of film production by the coating industry is based on wet bench processes, where better understanding of their temporal dynamics could facilitate control and optimization. In this work, in situ laser interferometry is applied to study properties of flowing liquids and quantitatively monitor the dip coating batch process. Two oil standards Newtonian, non-volatile, with constant refractive indices and distinct flow properties - were measured under several withdrawing speeds. The dynamics of film physical thickness then depends on time as t(-1/2), and flow characterization becomes possible with high precision (linear slope uncertainty of +/-0.04%). Resulting kinematic viscosities for OP60 and OP400 are 1,17 +/- 0,03. St and 9,9 +/- 0,2 St, respectively. These results agree with nominal values, as provided by the manufacturer. For more complex films (a multi-component sol-gel Zirconyl Chloride aqueous solution) with a varying refractive index, through a direct polarimetric measurement, allowing also determination of the temporal evolution of physical thickness (uncertainty of +/- 0,007 microns) is also determined during dip coating.
Resumo:
Measurement of the phase difference between the 0th and the 1st transmitted diffraction orders of a symmetrical surface-relief grating recorded on a photoresist film is carried out by replacement of the grating in the same setup with which it was recorded. The measurement does not depend on lateral shifts of the replaced grating relative to the interference pattern, on environmental phase perturbations or on the wave-front quality of the interfering beams. The experimental data agree rather well with theoretical results calculated for sinusoidal profiled gratings. (C) 2003 Optical Society of America.
Resumo:
Profilometry by electronic speckle pattern interferometry with multimode diode lasers is both theoretically and experimentally studied. The multiwavelength character of the laser emission provides speckled images covered with interference fringes corresponding to the surface relief in single-exposure processes. For fringe pattern evaluation, variations of the phase-stepping technique are investigated for phase mapping as a function of the number of laser modes. Expressions for two, three, and four modes in four and eight stepping are presented, and the performances of those techniques are compared in the experiments through the surface shaping of a flat bar. The surface analysis of a peach points out the possibility of applying the technique in the quality control of food production and agricultural research. (c) 2007 Optical Society of America.
Resumo:
The J(1)...J(3) is a recent optical method for linear readout of dynamic phase modulation index in homodyne interferometers. In this work, the J(1)... J(3) method is applied to measure voltage in an optical voltage sensor. Based on the classical J(1)...J(4) method, the J(1)... J(3) technique shows to be more stable to phase drift and simpler for implementation than the original one. The sensor dynamic range is enhanced. The agreement between theoretical and experimental results, based on 1/f noise, is demonstrated.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The serological detection of antibodies against human papillomavirus (HPV) antigens is a useful tool to determine exposure to genital HPV infection and in predicting the risk of infection persistence and associated lesions. Enzyme-linked immunosorbent assays (ELISAs) are commonly used for seroepidemiological studies of HPV infection but are not standardized. Intra-and interassay performance variation is difficult to control, especially in cohort studies that require the testing of specimens over extended periods. We propose the use of normalized absorbance ratios (NARs) as a standardization procedure to control for such variations and minimize measurement error. We compared NAR and ELISA optical density (OD) values for the strength of the correlation between serological results for paired visits 4 months apart and HPV-16 DNA positivity in cervical specimens from a cohort investigation of 2,048 women tested with an ELISA using HPV-16 virus-like particles. NARs were calculated by dividing the mean blank-subtracted (net) ODs by the equivalent values of a control serum pool included in the same plate in triplicate, using different dilutions. Stronger correlations were observed with NAR values than with net ODs at every dilution, with an overall reduction in nonexplained regression variability of 39%. Using logistic regression, the ranges of odds ratios of HPV-16 DNA positivity contrasting upper and lower quintiles at different dilutions and their averages were 4.73 to 5.47 for NARs and 2.78 to 3.28 for net ODs, with corresponding significant improvements in seroreactivity-risk trends across quintiles when NARs were used. The NAR standardization is a simple procedure to reduce measurement error in seroepidemiological studies of HPV infection.
Resumo:
Fluoroindate glasses containing 1, 2, 3, and 4 mol% ErF3 were prepared in a dry box under an argon atmosphere. Absorption spectra of these glasses at room temperature were obtained. The Judd-Ofelt parameters Ωλ (λ = 2, 4, 6) for f-f transitions of Er3+ ions as well as transition probabilities, branching ratios, radiative lifetimes, and peak cross-sections for stimulated emission of each band were determined. The concentration effect on the intensities is analyzed. The optical properties of the fluoroindate glasses doped with Er3+ ions are compared with those of other glasses described in the literature. © 1995.
Resumo:
Glasses of composition 40InF3-20SrF2-16BaF2-20ZnF 2-2GdF3-2NaF (mol%) have been prepared under controlled atmosphere. The time response of the stresses under the application of a constant strain was determined by microellipsometer technique, performed in ambient atmosphere at T < Tg = 294°C. The glasses show a Newtonian behavior at small stress level. During the relaxation process, very small grooves perpendicular to the applied strain appeared on the glass surface and affected its behavior after a time. The formation of these grooves is associated with the ambient atmosphere. Measurements in dry atmosphere showed that humidity was an important parameter in the relaxation process.
Resumo:
Starting from aqueous colloidal suspensions, undoped and Nb5+ doped SnO2 thin films have been prepared by using the dip-coating sol gel process. X-ray diffraction results show that films are polycrystalline with crystallites of average size1-4nm. Decreasing the thickness of the films and increasing the Nb5+ concentration limits the crystallite size growth during firing. Complex impedance measurements reveal capacitive and resistive effects between adjacent crystallites or grains, characteristic of electrical potential barriers. The transfer of charge throughout these barriers determines the macroscopic electrical resistance of the layer. The analysis of the optical absorption spectra shows that the samples present more than 80% of their transmittance in the visible region and the value of the band gap energy increases with decreasing crystallite size. © 1997 Chapman & Hall.
Resumo:
Optical absorption, Stokes, and anti-Stokes photoluminescence were performed on Er3+-Yb3+ co-doped fluoroindate glasses. For compounds prepared with a fixed 2 mol % ErF3 concentration and YbF3 contents ranging from 0 to 8 mol %, important upconversion processes were observed as a function of temperature and photon excitation energy. Based on the experimental data, two mechanisms for the upconversion (or anti-Stokes photoluminescence) processes were identified and analyzed in detail. At high Yb contents, the upconversion mechanisms are mostly determined by the population of the 2F5/2 levels of Yb3+ ions (or 4I11/2 levels of Er3+ ions, by energy transfer) regardless of the photon excitation energy and temperature of measurement. Moreover, green and red light emission have similar intensities when a large Yb3+ content is present. © 1998 American Institute of Physics.
Resumo:
Piezoelectric actuators are widely used in positioning systems which demand high resolution such as scanning microscopy, fast mirror scanners, vibration cancellation, cell manipulation, etc. In this work a piezoelectric flextensional actuator (PFA), designed with the topology optimization method, is experimentally characterized by the measurement of its nanometric displacements using a Michelson interferometer. Because this detection process is non-linear, adequate techniques must be applied to obtain a linear relationship between an output electrical signal and the induced optical phase shift. Ideally, the bias phase shift in the interferometer should remain constant, but in practice it suffers from fading. The J1-J4 spectral analysis method provides a linear and direct measurement of dynamic phase shift in a no-feedback and no-phase bias optical homodyne interferometer. PFA application such as micromanipulation in biotechnology demands fast and precise movements. So, in order to operate with arbitrary control signals the PFA must have frequency bandwidth of several kHz. However as the natural frequencies of the PFA are low, unwanted dynamics of the structure are often a problem, especially for scanning motion, but also if trajectories have to be followed with high velocities, because of the tracking error phenomenon. So the PFA must be designed in such a manner that the first mechanical resonance occurs far beyond this band. Thus it is important to know all the PFA resonance frequencies. In this work the linearity and frequency response of the PFA are evaluated up to 50 kHz using optical interferometry and the J1-J4 method.