35 resultados para Methods Time Measurement (MTM)

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The real-time monitoring of events in an industrial plant is vital, to monitor the actual conditions of operation of the machinery responsible for the manufacturing process. A predictive maintenance program includes condition monitoring of the rotating machinery, to anticipate possible conditions of failure. To increase the operational reliability it is thus necessary an efficient tool to analyze and monitor the equipments, in real-time, and enabling the detection of e.g. incipient faults in bearings. To fulfill these requirements some innovations have become frequent, namely the inclusion of vibration sensors or stator current sensors. These innovations enable the development of new design methodologies that take into account the ease of future modifications, upgrades, and replacement of the monitored machine, as well as expansion of the monitoring system. This paper presents the development, implementation and testing of an instrument for vibration monitoring, as a possible solution to embed in industrial environment. The digital control system is based on an FPGA, and its configuration with an open hardware design tool is described. Special focus is given to the area of fault detection in rolling bearings. © 2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper aims to survey data to analyze the productive capacity of a machining process of rolling bearings by methods-time measurement, in order to identify its bottlenecks and propose improvements in the system. The production times at the company are not known, the method of separation of operations and identification of its activities and the timing of production times and setup become points of departure for this paper. The results from this method of analysis provide clarity in identifying system weaknesses and by them it was possible to carry out the proposals for improvement in some process steps. The implementation of the improvements was not performed, but with the goals of this work was made possible to raise relevant information of the analyzed system

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the tropical Atlantic Forest, 42 canopy gaps had their areas estimated using four different field methods of measurement: Runkle, Brokaw and Green [Runkle, J.R., 1981. Gap formation in some old-growth forests of the eastern United States. Ecology 62, 1041-1051; Brokaw, N.V.L., 1982. The definition of treefall gap and its effect on measures of forest dynamics. Biotropica 14, 158-160; Green, P.T., 1996. Canopy Gaps in rain forest on Christmas Island, Indian Ocean: size distribution and methods of measurement. J. Trop. Ecol. 12, 427-434] and a new method proposed in this work. It was found that within the same gap delimitation, average gap size varied from 56.0 up to 88.3 m(3) while total sum of gap area varied from 2351.3 to 3707.9 m(3) Differences among all methods and between pairs of method proved to be statistically significant. As a consequence, gap size-class distribution was also different between methods. When one method is held as a standard, deviation on average values of gap size ranged between 11.8 and 59.7% as deviations on single gap size can reach 172.8%. Implications on forest dynamics were expressed by the forest turnover rate that was 24% faster or 15% slower depending on the method adopted for gap measurement. Based on my results and on methods' evaluation, the use of a new method is proposed here for future research involving the measure of gap size in forest ecosystems. Finally, it is concluded that forest comparisons disregarding the influence of different methods of gap measurement should be reconsidered. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes to use a state-space technique to represent a frequency dependent line for simulating electromagnetic transients directly in time domain. The distributed nature of the line is represented by a multiple 1t section network made up of the lumped parameters and the frequency dependence of the per unit longitudinal parameters is matched by using a rational function. The rational function is represented by its equivalent circuit with passive elements. This passive circuit is then inserted in each 1t circuit of the cascade that represents the line. Because the system is very sparse, it is possible to use a sparsity technique to store only nonzero elements of this matrix for saving space and running time. The model was used to simulate the energization process of a 10 km length single-phase line. ©2008 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate reproducibility and precision of ocular measurements by digital photograph analysis, in addition to the transformation of the measures according to the individual iris diameter as an oculometric reference. Methods: Twenty-four eyes have been digitally photographed in a standardized way at two distances. Two researchers have analyzed these printed images using a caliper and these digital forms by ImageJ 1.37 (TM). Several external ocular parameters were estimated (mm and as iris diameter) and methods of measurement compared regarding their precision, agreement and correlation. Results: Caliper and digital analysis of oculometric measures provided significant agreement and correlation, nevertheless the precision of digital measures was higher. The estimates of numeric transformation from oculometric measures according to individual iris diameter resulted in great correlation to caliper measures and high agreement when compared to different distances of taking the photographs. Conclusions: Facial digital photographs allowed oculometric precise and reproducible estimates, endorsing clinical research usefulness. Using iris diameter as individual oculometric reference disclosed high reproducibility when facial photographs were taken at different distances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A fluorometric technique based on a liquid drop excited from its interior by an optical fiber is described for the measurement of low concentrations of atmospheric hydrogen sulfide (H2S). A drop of alkaline fluorescein mercuric acetate (FMA) solution is suspended in a flowing air sample stream and serves as a renewable sensor. An optical fiber contained within the conduit that forms the drop, brings in the excitation beam; the fluorescence emission is measured by an inexpensive photodiode positioned close to the drop. As H2S in the sample is collected by the alkaline drop, it reacts rapidly with FMA resulting in a significant decrease in fluorescence intensity, proportional to the concentration of H2S sampled. The chemistry of this uniquely selective reaction has been well established for many years, the present technique permits a simple fast inexpensive near real-time measurement with very little reagent consumption. Even without prolonged sampling/preconcentration steps, limits of detection (LODs) in the double digit ppbv range is readily attainable. (C) 1997 Elsevier B.V. B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and sensitive method to determine parts per billion (ppb) of atmospheric formaldehyde in situ, using chromotropic acid, is described. A colorimetric sensor, coupled to a droplet of 15.5 muL chromotropic acid, was constructed and used to sample and quantify formaldehyde. The sensor was set up with two optical fibers, a right emitting diode (LED) and two photodiodes. The reference and transmitted light were measured by a photodetection arrangement that converts the signals into units of absorbance. Air was sampled around the chromotropic acid droplet. A purple product was formed and measured after the sampling terminated (typically 7 min). The response is proportional to the sampling period, analyte concentration and sample flow rate. The detection limit is similar to2 ppb and can be improved by using longer sampling times and/or a sampling flow rate higher than that used in this work, 200 mL min(-1). The present technique affords a simple, inexpensive near real-time measurement with very little reagent consumption. The method is selective and highly sensitive. This sensor could be used either for outdoor or indoor atmospheres.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The measurement of sulfur dioxide in air at the parts-per-billion level is described. The experimental arrangement consists of two optical fibers placed on opposite sides of a liquid droplet of malachite green solution. After light has been passed through the droplet, the transmitted light is measured by a referenced photodetection arrangement. The light used in this absorption process is from a monochromatic source (lambda(max) 625 nm). This arrangement permits the variation of color in the droplet to be measured. The sulfur dioxide in the sample is collected by the droplet; it reacts with malachite green resulting in a colorless dye. The decoloration of the solution is proportional to the concentration of sulfur dioxide sampled. The signal depends on the sample flow rate. The present technique is simple, inexpensive, and permits a fast and near real time measurement while consuming very little reagent, (C) 1999 Academic Press.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The inclusion of the corona effect in a frequency dependent transmission line model is proposed in this paper. The transmission line is represented through a cascade of π circuits and the frequency dependence of the longitudinal parameters is synthesized with series and parallel resistors and inductors. The corona effect will be represented using the Gary and Skilling-Umoto models. The currents and voltages along the line are calculated by using state-space technique. To demonstrate the accuracy and validity of the proposed frequency dependent line model, time domain simulations of a 10 km length single-phase line response under energization procedure will be presented. ©2008 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a computational model based on lumped elements for the mutual coupling between phases in three-phase transmission lines without the explicit use of modal transformation matrices. The self and mutual parameters and the coupling between phases are modeled using modal transformation techniques. The modal representation is developed from the intrinsic consideration of the modal transformation matrix and the resulting system of time-domain differential equations is described as state equations. Thus, a detailed profile of the currents and the voltages through the line can be easily calculated using numerical or analytical integration methods. However, the original contribution of the article is the proposal of a time-domain model without the successive phase/mode transformations and a practical implementation based on conventional electrical circuits, without the use of electromagnetic theory to model the coupling between phases. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a computational model based on lumped elements for the mutual coupling between phases in transmission lines without the explicit use of modal transformation matrices. The self and mutual parameters and the coupling between phases are modeled using modal transformation techniques. The modal representation is developed from the intrinsic consideration of the modal transformation matrix and the resulting system of time-domain differential equations is described as state equations. Thus, a detailed profile ofthe currents and the voltages through the line can be easily calculated using numerical or analytical integration methods. However, the original contribution of the article is the proposal of a time-domain model without the successive phase/mode transformations and a practical implementation based on conventional electrical circuits, without the use of electromagnetic theory to model the coupling between phases. © 2003-2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)