107 resultados para Lung clearance

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Smoking impairs mucociliary clearance and increases respiratory infection frequency and severity in subjects with and without smoking-related chronic lung diseases. Objective: This study evaluated the effects of smoking intensity on mucociliary clearance in active smokers. Methods: Seventy-five active smokers were grouped into light (1-10 cigarettes/day; n = 14), moderate (11-20 cigarettes/day; n = 34) and heavy smokers (≥21 cigarettes/day; n = 27) before starting a smoking cessation programme. Smoking behaviour, nicotine dependence, pulmonary function, carbon monoxide in exhaled air (exCO), carboxyhaemoglobin (COHb) and mucociliary clearance measured by the saccharin transit time (STT) test were all evaluated. An age-matched non-smoker group (n = 24) was assessed using the same tests. Results: Moderate (49 ± 7 years) and heavy smokers (46 ± 8 years) had higher STT (p = 0.0001), exCO (p < 0.0001) and COHb (p < 0.0001) levels compared with light smokers (51 ± 15 years) and non-smokers (50 ± 11 years). A positive correlation was observed between STT and exCO (r = 0.4; p < 0.0001), STT and cigarettes/day (r = 0.3, p = 0.02) and exCO and cigarettes/day (r = 0.3, p < 0.01). Conclusion: Smoking impairs mucociliary clearance and is associated with cigarette smoking intensity. Copyright © 2013 S. Karger AG, Basel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objectives: The efficiency of mucociliary transport may vary in different conditions, such as in exposure to harmful particles of the cigarette smoke. The present study evaluated the acute and short term effects of smoking on nasal mucociliary clearance in current smokers by the quantification of the Saccharin Transit Time (STT), and to investigate its correlation with the history of tobacco consumption.Methods: Nineteen current smokers (11 men, 51 +/- 16 years; BMI 23 +/- 9 kg/m(2), 27 +/- 11 cigarettes per day, 44 +/- 25 pack-years), entering a smoking cessation intervention program, responded to a questionnaire concerning smoking history and were submitted to lung function assessment (spirometry) and the STT test. STT was assessed immediately after smoking and 8 hours after smoking. The STT test was also performed in nineteen matched healthy non-smokers' who served as control group.Results: When compared to STT in non-smokers' (10 +/- 4 min; mean +/- standard deviation), smokers presented similar STT immediately after smoking (11 +/- 6 min; p = 0.87) and slower SIT 8 hours after smoking (16 +/- 6 min; p = 0.005 versus non-smokers' and p = 0.003 versus immediately after smoking). STT 8 hours after smoking correlated positively with age (r = 0.59; p = 0.007), cigarettes per day (r = 0.53; p = 0.02) and pack-years index (r = 0.74; p = 0.0003).Conclusions: In smokers, although the mucociliary clearance immediately after smoking is similar to non-smokers', eight hours after smoking it is reduced, and this reduction is closely related to the smoking habits. (C) 2010 Sociedade Portuguesa de Pneumologia. Published by Elsevier Espana, S.L. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thalidomide is a selective inhibitor of tumor necrosis factor-alpha (TNF-alpha), a cytokine involved in mycobacterial death mechanisms. We investigated the role of this drug in the functional activity of alveolar macrophages in the presence of infection induced by intranasal inoculation of Mycobacterium avium in thalidomide-treated and untreated adult Swiss mice. Sixty animals were inoculated with 5 x 10(6) M. avium by the respiratory route. Thirty animals received daily thalidomide (30 mg/kg mouse) and 30 received water by gavage up to sacrifice. Ten non-inoculated mice were used as a control group. Lots of animals from each group were evaluated until 6 weeks after inoculation. Infection resulted in an increased total number of inflammatory cells as well as increased activity of pulmonary macrophages. Histologically, intranasal inoculation of bacilli resulted in small mononuclear infiltrates located at the periphery of the organ. Culture of lung fragments revealed the presence of bacilli only at the beginning and at the end of the experimental period. Thalidomide administration did not affect the microbiological or histological features of the infection. Thalidomide-treated and untreated animals showed the same amount of M. avium colonies 3 weeks after infection. Although it did not affect bacillary clearance, thalidomide administration resulted in a decreased percent of spread cells and release of hydrogen peroxide, suggesting that factors other than TNF-alpha play a role in the killing of mycobacteria by alveolar macrophages. Thalidomide administration also reduced the number of spread cells among resident macrophages, suggesting a direct effect of the drug on this phenomenon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a non-isothermal two-phase model for oil-R134a refrigerant mixture flow is presented to predict the R134a leakage through the radial clearance of rolling piston compressors. The flow is divided in a liquid single-phase region and in a two-phase region, in which the homogeneous model is used to simulate the flow. The refrigerant leakage is determined using the mixture mass flow rate and the refrigerant mass fraction variation along the flow. The results are obtained for inlet pressures varying from 200 to 700 kPa, inlet temperatures ranging from 40 to 60 degrees C, and minimal clearances between 10 and 60 mu m. The results are firstly compared to existing isothermal model data, showing that there is a significant difference between the leakage flow rates predicted by isothermal and non-isothermal models. Finally, a useful general equation for compressor designers is proposed to calculate the refrigerant leakage for a large range of operation conditions. (C) 2012 Elsevier Ltd and IIR. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In patients with acute respiratory distress syndrome, positive end-expiratory pressure is associated with alveolar recruitment and lung hyperinflation despite the administration of a low tidal volume. The best positive end-expiratory pressure should correspond to the best compromise between recruitment and distension, a condition that coincides with the best respiratory elastance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the efficiency of an Aeroneb Pro vibrating plate and an Atomisor MegaHertz ultrasonic nebulizer for providing ceftazidime distal lung deposition.Design: In vitro experiments. One gram of cetazidime was nebulized in respiratory circuits and mass median aerodynamic diameter of particles generated by ultrasonic and vibrating plate nebulizers was compared using a laser velocimeter. In vivo experiments. Lung tissue concentrations and extrapulmonary depositions were measured in ten anesthetized ventilated piglets with healthy lungs that received 1 g of ceftazidime by nebulization with either an ultrasonic (n = 5), or a vibrating plate (n = 5) nebulizer.Setting: A two-bed Experimental Intensive Care Unit of a University School of Medicine.Intervention: Following sacrifice, 5 subpleural specimens were sampled in dependent and nondependent lung regions for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography.Measurements and results: Mass median aerodynamic diameters generated by both nebulizers were similar with more than 95% of the particles between 0.5 and 5 mu m. Lung tissue concentrations were 553 +/- 123 [95% confidence interval: 514-638] mu g g(-1) using ultrasonic nebulizer, and 452 +/- 172 [95% confidence interval: 376-528] mu g g(-1) using vibrating plate nebulizers (NS). Extrapulmonary depositions were, respectively, of 38 +/- 5% (ultrasonic) and 34 +/- 4% (vibrating plate) (NS).Conclusions: Vibrating plate nebulizer is comparable to ultrasonic nebulizers for ceftazidime nebulization. It may represent a new attractive technology for inhaled antibiotic therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose of reviewLung ultrasound at the bedside can provide accurate information on lung status in critically ill patients with acute respiratory distress syndrome.Recent findingsLung ultrasound can replace bedside chest radiography and lung computed tomography for assessment of pleural effusion, pneumothorax, alveolar- interstitial syndrome, lung consolidation, pulmonary abscess and lung recruitment/de-recruitment. It can also accurately determine the type of lung morphology at the bedside (focal or diffuse aeration loss), and therefore it is useful for optimizing positive end-expiratory pressure. The learning curve is brief, so most intensive care physicians will be able to use it after a few weeks of training.SummaryLung ultrasound is noninvasive, easily repeatable and allows assessment of changes in lung aeration induced by the various therapies. It is among the most promising bedside techniques for monitoring patients with acute respiratory distress syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The best way to study compensatory lung growth (CLG) is in a transplant without rejection. Since immunosuppressive drugs may influence CLG, it is better to not use them. Therefore we studied CLG in a reimplant of only one lobe after its removal. The objective was to compare lobar transplant CLG with CLG after lobectomy.Methods. Forty eight dogs were distributed in three groups: G1 = control, G2 = left cranial lobectomy, and G3 = left pneumonectomy with reimplantation of the caudal lobe. Five months after surgery the animals underwent lung scintigraphy and were sacrificed for morphometric study.Results. There was no correlation between scintigraphy and lung mass or lung volume. There was both mass and residual volume CLG in the operated groups, both contralateral and ipsilateral to surgery. There was no compensation for total lung capacity or compliance in the remaining caudal lobe (G2) or the reimplanted caudal lobe (G3) at 5 months after surgery. There was more damage in the reimplanted lobe. As previous studies have shown that CLG starts with increased mass and residual volume and compliance is compensated later. This study seemed to document the beginning of CLG, with lung compliance being the limiting factor of CLG at 5 months.Conclusion. There was CLG in both the reimplanted lobe and the contralateral lung, but compliance was still reduced. CLG was similar in both groups, but in the implanted lobe compliance was more prejudiced.