174 resultados para Irrigation system design

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In trickle irrigation systems, the design is based on the pre-established emission uniformity (EU) which is the combined result of the equipment characteristics and its hydraulic configuration. However, this desired value of the EU may not be confirmed by the final project (in field conditions) and neither by the yield uniformity. The hypotheses of this research were: a) the EU of a trickle irrigation system at field conditions is equal to the emission uniformity pre-established in the its design; b) EU has always the lowest value when compared with other indicators of uniformity; c) the discharge variation coefficient (VC) is not equal to production variation coefficient in the operational unit; d) the difference between the discharge variation coefficient and the productivity variation coefficient depends on the water depth applied. This study aimed to evaluate the relationship between EU used in the irrigation system design and the final yield uniformity. The uniformity indicators evaluated were: EU, distribution uniformity (UD) and the index proposed by Barragan & Wu (2005). They were compared estimating the performance of a trickle irrigation system applied in a citrus orchard with dimensions of 400m x 600m. The design of the irrigation system was optimized by a Linear Programming model. The tree rows were leveled in the larger direction and the spacing adopted in the orchard was 7m x 4m. The manifold line was always operating on a slope condition. The sensitivity analysis involved different slopes, 0, 3, 6, 9 and 12%, and different values of emission uniformity, 60, 70, 75, 80, 85, 90 and 94%. The citrus yield uniformity was evaluated by the variation coefficient. The emission uniformity (EU) after design differed from the EU pre-established, more sharply in the initial values lower than 90%. Comparing the uniformity indexes, the EU always generated lower values when compared with the UD and with the index proposed by Barragan. The emitter variation coefficient was always lower than the productivity variation coefficient. To obtain uniformity of production, it is necessary to consider the irrigation system uniformity and mainly the water depth to be applied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cogeneration system design deals with several parameters in the synthesis phase, where not only a thermal cycle must be indicated but the general arrangement, type, capacity and number of machines need to be defined. This problem is not trivial because many parameters are considered as goals in the project. An optimization technique that considers costs and revenues, reliability, pollutant emissions and exergetic efficiency as goals to be reached in the synthesis phase of a cogeneration system design process is presented. A discussion of appropriated values and the results for a pulp and paper plant integration to a cogeneration system are shown in order to illustrate the proposed methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cogeneration system design deals with several parameters in the synthesis phase, where not only a thermal cycle must be indicated but the general arrangement, type, capacity and number of machines need to be defined. This problem is not trivial because many parameters are considered as goals in the project. An optimization technique that considers costs and revenues, reliability, pollutant emissions and exergetic efficiency as goals to be reached in the synthesis phase of a cogeneration system design process is presented. A discussion of appropriated values and the results for a pulp and paper plant integration to a cogeneration system are shown in order to illustrate the proposed methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the comparison of three topologies of multilevel inverters applied to drive an induction motor of 500 kVA/4.16 kV. The multilevel inverters analyzed are: a neutral point clamped inverter, a symmetrical cascaded multilevel inverter and a hybrid asymmetrical cascaded multilevel inverter. The performance indexes used in the comparison are total harmonic distortion, first order distortion factor, semiconductors power losses distribution and heat-sink volume. The comparison is developed with the purpose of finding the efficiency and the heat-sink volume where the three systems present the same output filter. ©2008 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The constant increase in digital systems complexity definitely demands the automation of the corresponding synthesis process. This paper presents a computational environment designed to produce both software and hardware implementations of a system. The tool for code generation has been named ACG8051. As for the hardware synthesis there has been produced a larger environment consisting of four programs, namely: PIPE2TAB, AGPS, TABELA, and TAB2VHDL. ACG8051 and PIPE2TAB use place/transition net descriptions from PIPE as inputs. ACG8051 is aimed at generating assembly code for the 8051 micro-controller. PIPE2TAB produces a tabular version of a Mealy type finite state machine of the system, its output is fed into AGPS that is used for state allocation. The resulting digital system is then input to TABELA, which minimizes control functions and outputs of the digital system. Finally, the output generated by TABELA is fed to TAB2VHDL that produces a VHDL description of the system at the register transfer level. Thus, we present here a set of tools designed to take a high-level description of a digital system, represented by a place/transition net, and produces as output both an assembly code that can be immediately run on an 8051 micro-controller, and a VHDL description that can be used to directly implement the hardware parts either on an FPGA or as an ASIC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Visando caracterizar a distribuição de freqüência da evapotranspiração de referência na região de Piracicaba, SP, e avaliar as práticas usuais de estimativa da necessidade de água para fins de dimensionamento de sistemas de irrigação, foram utilizados 30 anos de dados de evapotranspiração do mês de setembro, que foi dividido em períodos de 5, 10, 15 e 30 dias. As distribuições Beta e Normal foram aplicadas aos dados e ambas mostraram-se aptas para representá-los. Para valores de probabilidade de ocorrência iguais ou superiores a 60%, verificou-se o aumento do valor da evapotranspiração de referência com a diminuição do período. Adotando como parâmetros o período de máxima exigência hídrica de 2 a 3 semanas e a evapotranspiração de referência ao nível de 75% de probabilidade, verificou-se que o uso do valor médio mensal da evapotranspiração no dimensionamento de sistemas de irrigação conduz ao subdimensionamento, enquanto a adoção do máximo valor diário da evapotranspiração acarreta o superdimensionamento.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When an area to be irrigated has a high slope gradient in the manifold line direction, an option is to use a tapered pipeline to economize on pipe costs and to keep pressure head variations within desired limits. The objective of this paper is to develop a linear optimization model to design a microirrigation system with tapered, downhill manifold lines, minimizing the equivalent annual cost of the hydraulic network and the annual pumping cost, and maximizing the emission uniformity previously established to the subunit. The input data are irrigation system layout, cost of all hydraulic network components, and electricity price. The output data are equivalent annual cost, pipeline diameter in each line of the system, pressure head in each node, and total operating pressure head. To illustrate its capability, the model is applied in a citrus orchard in Sao, Paulo State, Brazil, considering slopes of 3, 6, and 9%. The model proved to be efficient in the design of the irrigation system in terms of the emission uniformity desired.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Upland rice (Oryza sativa L.) cultivation has been increasing in importance in Asia while water availability for irrigation has been decreasing because of rapid growth in industry and urban centers. Therefore, the development of technologies that increase upland rice yields under aerobic conditions, thereby saving water, would be an effective strategy to avoid a decrease in global rice grain production. The use of the no-tillage system (NTS) and cover crops that maintain soil moisture would prove advantageous in the move toward sustainable agriculture. However, upland rice develops better in plowed soil, and it has been reported that this crop does not perform well under the NTS. Therefore, the aim of this study was to investigate the effect of cover crops on upland rice grain yield and yield components sowed in a NTS. A field experiment was conducted during two growing seasons (2008-2009 and 2009-2010), and treatments consisted of growing rice under five cover crops in a NTS and two control treatments under the conventional tillage system (plowing once and disking twice). Treatments were carried out in a randomized block design with three replications. Our findings are as follows: On average, Brachiaria brizantha (12.32Mgha-1), Brachiaria ruziziensis (11.08Mgha-1) and Panicum maximum (11.62Mgha-1) had outstanding biomass production; however, these grasses provided the worst upland rice yields (2.30, 2.04, and 2.67Mgha-1, respectively) and are not recommended as cover crops before upland rice. Millet and fallow exhibited the fastest straw degradation (half-lives of 52 and 54 days, respectively), and millet exhibited the fastest nitrogen release (N half-life of 28 days). The use of a NTS was promising when millet was used as a cover crop; this allowed the highest upland rice yield (3.94Mgha-1) and did not statistically differ from plowed fallow (3.52Mgha-1). © 2012 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quando a área a ser irrigada apresenta um elevado gradiente de declive na direção das linhas de derivação, uma opção de dimensionamento é o uso de tubulações com vários diâmetros para economizar no custo e também para manter a variação de pressão dentro dos limites desejados. O objetivo deste trabalho foi desenvolver um modelo de programação linear para dimensionar sistemas de irrigação por microaspersão com linhas de derivação com mais de um diâmetro e operando em declive, visando a minimização do custo anualizado da rede hidráulica e do custo anual com energia elétrica, além de assegurar que a máxima variação de carga hidráulica na linha será respeitada. Os dados de entrada são: configuração da rede hidráulica do sistema de irrigação, custo de todos os componentes da rede hidráulica e custo da energia. Os dados de saída são: custo anual total, diâmetro da tubulação em cada linha do sistema, carga hidráulica em cada ponto de derivação e altura manométrica total. Para ilustrar a potencialidade do modelo desenvolvido, ele foi aplicado em um pomar de citros no Estado de São Paulo, Brasil. O modelo demonstrou ser eficiente no dimensionamento do sistema de irrigação quanto à obtenção da uniformidade de emissão desejada. O custo anual com bombeamento deve ser considerado no dimensionamento de sistemas de irrigação por microaspersão porque ele gera menores valores de custo anual total quando comparado com a mesma alternativa que não considera aquele custo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare the use of water and nitrogen on ratoon sugarcane during irrigated and rain-fed conditions, and to assess the production potential of stalks and sugar with different rates of N-fertilizer on the subsurface drip-irrigated management. The experimental design was a randomized block with four replications for each experiment and treatments: (T1) irrigated, 0kg N ha-1; (T2) irrigated, 70kg N ha-1; (T3) irrigated, 140kg N ha-1; (T4) irrigated, 210kg N ha-1; (T5) not irrigated, 0kg N ha-1, and (T6) not irrigated, 140kg N ha-1. Biometric, technological, dry matter and yield variables were analyzed among the treatments. The irrigation system together with the application of N-fertilizer at 140kg ha-1 presented significant differences in dry matter accumulation of shoots, and for the production of stalks and sugar, respectively 94, 105 and 106%, higher when compared to the not irrigated, without N-fertilizer (T5). There was a positive and synergistic effect of irrigation with N-fertilizer on the productivity of stalks and sugar. Ratoon sugarcane irrigated with subsurface dripping had the highest yield (22Mg ha-1 of sugar) with the dosage of 140kg ha-1 N.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A aplicação de fertilizantes fosfatados por meio de fertirrigação com sistemas de irrigação localizada pode causar obstrução de emissores. Para evitar esse problema, pode ser utilizado o ácido fosfórico como fonte de fósforo às plantas. Porém, têm sido pouco investigados os efeitos da irrigação relacionados às perdas de CO2 do solo para a atmosfera, em conseqüência da decomposição do carbono orgânico e da infiltração de água no solo. Neste trabalho, investigou-se, no período de um mês, o efeito da fertirrigação com ácido fosfórico nas taxas de emissão de CO2 de um latossolo desprovido de vegetação, na Área Experimental de Irrigação da UNESP, Câmpus de Jaboticabal - SP. Utilizou-se de um sistema de irrigação por gotejamento, com delineamento experimental em blocos casualizados, constando de cinco repetições e cinco tratamentos (0; 30; 60; 90 e 120 kg ha-1de P2O5), aplicados via fertirrigação com ácido fosfórico. Verificou-se que as taxas de emissão de CO2 aumentaram significativamente após as fertirrigações, porém não houve efeito da dose do ácido fosfórico sobre as taxas. A umidade do solo mostrou-se um fator importante na relação entre as variações das taxas de emissão e a temperatura do solo ao longo do período estudado.