68 resultados para In Vitro Techniques
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The aim of this study was to compare 2 different methods of assessment of implants at different inclinations (90 degrees and 65 degrees)-with a profilometer and AutoCAD software. Materials and Methods: Impressions (n = 5) of a metal matrix containing 2 implants, 1 at 90 degrees to the surface and 1 at 65 degrees to the surface, were obtained with square impression copings joined together with dental floss splinting covered with autopolymerizing acrylic resin, an open custom tray, and vinyl polysiloxane impression material. Measurement of the angles (in degrees) of the implant analogs were assessed by the same blinded operator with a profilometer and through analysis of digitized images by AutoCAD software. For each implant analog, 3 readings were performed with each method. The results were subjected to a nonparametric Kruskal-Wallis test, with P <= .05 considered significant. Results: For implants perpendicular to the horizontal surface of the specimen (90 degrees), there were no significant differences between the mean measurements obtained with the profilometer (90.04 degrees) and AutoCAD (89.95 degrees; P=.9142). In the analyses of the angled implants at 65 degrees in relation to the horizontal surface of the specimen, significant differences were observed (P=.0472) between the mean readings with the profilometer (65.73 degrees) and AutoCAD (66.25 degrees). Conclusions: The degrees of accuracy of implant angulation recording vary among the techniques available and may vary depending on the angle of the implant. Further investigation is needed to determine the best test conditions and the best measuring technique for determination of the angle of the implant in vitro.
Resumo:
Among the osteotomies performed in orthognathic surgery, the sagittal osteotomy of the mandibular ramus (SOMR) is the most common, allowing a great range of movements and stable internal fixation (SIF), therefore eliminating the need of maxillomandibular block in the postoperative period. Objectives: The purpose of this study was to evaluate the biomechanical resistance of three national systems used for SIF in SOMR in sheep mandibles. Material and methods: The study was performed in 30 sheep hemi-mandibles randomly divided into 3 experimental groups, each containing 10 hemi-mandibles. The samples were measured to avoid discrepancies and then subjected to SOMR with 5-mm advancement. In group I, 2.0x12 mm screws were used for fixation, inserted in an inverted "L" pattern (inverted "L" group). In group II, fixation was performed with two 2.0x12 mm screws, positioned in a linear pattern and a 4-hole straight miniplate and four 2.0x6.0 mm monocortical screws (hybrid group). In group III, fixation was performed with two-hole straight miniplates and eight 2.0x6.0 mm monocortical screws (mini plate group). All materials used for SIF were supplied by Osteosin - SIN. The hemimandibles were subjected to vertical linear load test by Kratos K2000MP mechanical testing unit for loading registration and displacement. Results: All groups showed similar resistance during mechanical test for loading and displacement, with no statistically significant differences between groups according to analysis of variance. Conclusion: These results indicate that the three techniques of fixation are equally effective for clinical fixation of SOMR.
Resumo:
Objectives: This in vitro study compared the dimensional accuracy of stone index (I) and three impression techniques: tapered impression copings (T), squared impression copings (S) and modified squared impression copings (MS) for implant-supported prostheses. Methods: A master cast, with four parallel implant abutment analogs and a passive framework, were fabricated. Vinyl polysiloxane impression material was used for all impressions with two metal stock trays (open and closed tray). Four groups (I, T, S and MS) were tested (n = 5). A metallic framework was seated on each of the casts, one abutment screw was tightened, and the gap between the analog of implant and the framework was measured with a stereomicroscope. The groups' measurements (80 gap values) were analyzed using software (LeicaQWin - Leica Imaging Systems Ltd.) that received the images of a video camera coupled to a Leica stereomicroscope at 100× magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, 0.05. Results: The mean values of abutment/framework interface gaps were: Master Cast = 32 μm (SD 2); Group I = 45 μm (SD 3); Group T = 78 μm (SD 25); Group S = 134 μm (SD 30); Group MS = 143 μm (SD 27). No significant difference was detected among Index and Master Cast (P = .05). Conclusion: Under the limitations of this study, it could be suggested that a more accurate working cast is possible using tapered impression copings techniques and stone index. © 2013 Japan Prosthodontic Society.
Resumo:
A study was made to compare dry matter, crude protein and gross energy digestibility of corn silage, associated to concentrate, through in vitro and in vivo digestion techniques. A completely randomized design was used, with two treatments and nine replications, involving three assays. The in vivo digestion assay was conducted with 12 Holstein heifers, on a 24 h permanent sample collection. The in vitro digestion assay was achieved with three collection methods: manual (M), vacuum pump (VP) and nasoesophagic (N). The collection methods VP and M can he used to determine the dry matter digestibility, instead of in vivo method, for the present study ration. The digestion methods influenced the DM, CP and GE digestibility for the studied ration.
Resumo:
The objective of this work was to evaluate the effect of the variables number of recipients, synchronization protocol, reproductive efficiency indicators and pregnancy cost, in the economic effectiveness of in vivo and in vitro bovine embryo production. A simulation application was elaborated to allow the user to insert the input variable parameters. A basic scenario, from the efficiency traditional rates of in vivo (ET) and in vitro production (IVP) techniques of bovine embryos, was introduced in the software as a criterion to compare the results. This software was able to reproduce both ET and IVP scenarios. The embryo production was simulated through stochastic simulation. The optimal number of recipients using sensitivity analysis was determined. The net present value and cost per pregnancy were used as a decision parameter. The synchronization for fixed-time embryo transfer decreased the recipient idleness and, consequently, the final cost of pregnancy, in comparison to the traditional methodology. Foetal sexing must be associated to IVP of bovine embryos. In addition, the optimal recipient number per donor is variable and depends on data inserted in the system.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The Joro spider toxin (JSTX-3), derived from Nephila clavata, has been found to block glutamate excitatory activity. Epilepsy has been studied in vitro, mostly on rat hippocampus, through brain slices techniques. The aim of this study is to verify the effect of the JSTX-3 on the epileptiform activity induced by magnesium-free medium in rat CA1 hippocampal neurons. Experiments were performed on hippocampus slices of control and pilocarpine-treated Wistar rats, prepared and maintained in vitro. Epileptiform activity was induced through omission of magnesium from the artificial cerebrospinal fluid (0-Mg2+ ACSF) superfusate and iontophoretic application of N-methyl-D-aspartate (NMDA). Intracellular recordings were obtained from CA] pyramidal neurons both of control and epileptic rats. Passive membrane properties were analyzed before and after perfusion with the 0-Mg2+ ACSF and the application of toxin JSTX-3. During the ictal-like activity, the toxin JSTX-3 was applied by pressure ejection, abolishing this activity. This effect was completely reversed during the washout period 2. when the slices were formerly perfused with artificial cerebrospinal fluid (ACSF) and again with 0-Mg2+ ACSF. Our results suggest that the toxin JSTX-3 is a potent blocker of induced epileptiform activity. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
OBJETIVO: Avaliar se fontes de luz aumentam a eficácia do peróxido de hidrogênio na técnica de clareamento profissional. METODOLOGIA: Foram empregados 60 dentes incisivos bovinos, com dimensões coronárias e radiculares padronizadas a partir do limite amelo-cementário, sendo descartada a porção lingual. Os corpos-de-prova (cp) foram limpos em ultra-som por 20 min e a dentina condicionada com H3PO4 a 38% por 15 s, sendo os (cp) imersos em solução de café solúvel a 25% por duas semanas. A dentina foi impermeabilizada com esmalte e os (cp) divididos em 5 grupos, sendo a cor inicial mensurada através do espectofotômetro-EasyShade (VITA). Todos os (cp) receberam três aplicações por 10 min do gel clareador Opalescence Xtra-Boost (Ultradent) conforme segue: Grupo 1 - controle, não recebeu fotoativação, Grupo 2 - ativado com luz halôgena, Grupo 3 - ativado com LED azul/LASER, Grupo 4 - ativado com LED verde/LASER e Grupo 5 - ativado com LED vermelho. Após o clareamento foi mensurada a variação de cor E, a*, b*e L* e as referentes à escala de cor Vita Clássico. Os dados foram submetidos à análise de variância, teste de Tukey e de Dunn (α=5%). RESULTADOS: A diferença geral da cor foi reduzida quando se empregou LED Azul e Luz Halógena, sendo que o desempenho do peróxido de hidrogênio a 38% foi intensificado dependendo da fonte de luz utilizada. A avaliação quantitativa de cor, obtida por espectrofotômetro e pela escala de cor Vita Clássico, foram coincidentes. CONCLUSÃO: O tipo de fonte de luz empregada interfere na eficácia do agente clareador.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Statement of problem. Prosthetic restorations that fit poorly may affect periodontal health and occlusion. Studies that have evaluated the accuracy of fit of ceramic restorations before and after cementation assessed primarily intracoronal restorations.Purpose. This in vitro study evaluated the effect of different finish lines, ceramic manufacturing techniques, and luting agents on the vertical discrepancy of ceramic copings.Material and methods. Two stainless steel molars were prepared for complete crowns with 2 different finish lines (heavy chamfer and rounded shoulder); each molar was duplicated to fabricate 90 copings. A total of 180 copings generated 18 groups (n=10 for each finish line-coping material-luting agent combination). Luting agents tested included zinc phosphate, resin-modified glass ionomer (Fuji Plus), and resin composite cements (Panavia F). A metal frame was developed on which to screw the stainless steel model and a ceramic coping; the distance (mum) between 2 predetermined points was measured before and after cementation by a profile projector under a torquing force. A 4-way ANOVA with repeated measurements was performed to assess the influence of each factor in the vertical marginal discrepancy: 3 between-coping factors (finish line-coping material-luting agent) and 1 within-coping factor (before and after cementation) (alpha=.05).Results. Procera copings presented the lowest mean values (P<.05) of vertical marginal discrepancy before and after cementation (25/44 mum) when compared to Empress 2 (68/110 mum) and InCeram Alumina copings (57/117 mum), regardless of any combinations among all finish lines and luting agents tested.Conclusion. Considering each factor separately, the ceramic manufacturing technique appeared to be the most important factor tested for the definitive vertical discrepancy of all-ceramic copings, with lower mean values for Procera copings.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)