121 resultados para Garantia da qualidade (Implantação)

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Geologia Regional - IGCE

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study is to perform a situational analysis of the Laboratory of pulp and paper-UNESP ITAPEVA for conducting proposal the accreditation according to ISO / IEC 17025:2005. The ISO / IEC 17025 establishes the criteria for those laboratories wishing to demonstrate their technical competence, which have an effective quality system and are able to generate technically valid results, establishing a single international standard for certifying the competence of laboratories to carry tests and / or calibrations, including sampling. The case study was conducted on laboratory Pulp and Paper Universidade Estadual Paulista (UNESP), campus Itapeva, where we compared the views of the technician responsible for the laboratory and a regular user. The generated conclusion is that the laboratory is unable to initiate an accreditation process, because it fails the requirements such as quality manual, register of subcontractors, research of customer satisfaction, schedule of internal audits, schedule for completion of critical analysis, profile of the functions required, functions current description, documentation of technical requirements for accommodation and environmental conditions, calibration programs, equipment calibration program, programs calibration standards and reports and / or certificate of test and / or calibration, that are in accordance with ISO / IEC 17025:2005, beyond that there is not the possibility to develop and implement a quality system without the commitment of everyone involved, regardless of the functional hierarchy

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The computed tomography, devised by Godfrey Hounsfield and Allan Cormack, is in its fourth decade of the clinical use and has presented to be a very useful tool in the diagnosis of several pathologies. For this reason, its use is increasing each day, due to technological progress since its creation. Due to be more and more utilized, the equipment must be in good operating conditions, because it is subject to variance and wearing, damage the quality of diagnosis. To evaluate whether the performance of the scanner remains constant along the time and the dose received by the patient is within the desired limits, periodic tests of quality control must be performed. For this subject, the regulation 453 (June 01, 1998) was created, which determines the need of the implementation of a program for quality assurance (PGQ), where, in addition to the tests of quality control, are established the necessary measurements for the proper functioning of the equipment, generating a trustworthy diagnosis, reducing the dose for the patient and the costs. In this document, are presented tests of quality control carried out in hospitals of the city of Sao Paulo carried out together with the Technical Section of Applications by Imaging Diagnostic (STADI) of the Institute of Electrotechnics and Energy of the University of São Paulo (IEE/USP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Brazil , the construction industry is on an upward trend, mainly by the housing shortage , and yet there are few builders that take a Quality Management System ( QMS ) to improve the quality of its services and processes . The ISO 9001 standards are guidelines for an effective QMS and this certificate is recognized worldwide as a seal of quality standard. This paper will describe and analyze the implementation of a QMS in a small construction company of Guaratinguetá - SP, identifying best practices and major difficulties , besides proposing preparatory recommendations for other companies that seek the ISO 9000 certification. Access to company’s data made the nonconformities and the customer satisfaction research analysis possible, and a questionnaire and unstructured interviews allowed a deeper understanding of the situation. Despite this ISO 9000 QMS not being fully implemented, the company has already conquered some improvements in document control, project planning, process traceability and established focus on customer

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Ciência da Computação - IBILCE

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Enfermagem (mestrado profissional) - FMB

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Currently, with the competitiveness that is seen in the market, it is crucial to the success of the business, develop new strategies to keep and win new customer preference. To ensure the success of a particular service or product, the secret is to continually meet the wishes and demands of the customers, which are the key parts of the business, through innovation, variety and quality assurance. To achieve this goal managers should be aware of all types of process that exist in the company, as they are primarily responsible and interested by quality service, customer satisfaction and consequently, generating favorable financial results. A tool used to ensure good results to business is the Quality Function Deployment (QFD) that seeks to hear and interpret customers requirements and turn them into essential features for a project

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Radiotherapy is a multidisciplinary speciality which uses complex equipment and radiation sources for delivery of treatment, using high-energy ionizing radiation to treat cancer at several stages of complexity. Since radiation therapy is a technique which involves a precalculated radiation dose, it shall be established quality assurance programs that provide an efficient and safety treatment. The International Commission on Radiation Units and Measurements (ICRU) report No. 50 has recommended dose uniformity between 5% of the prescribed dose throughout the region of interest. This is one of the most primordial points that justify the importance of a suitable attendance of the equipments quality and performance. For quality control, the medical physicist will be involved with establishing and running a Quality Control Program (QCP). He must adapt or develop the procedures of equipment acceptance and commissioning, besides verifying the use of principles and accepted protocols of national and international reports to assure the correct quality, quantity, and placement of radiation during the performance of a radiological procedure, establishing adequate protocols to ensure accurate patient dosimetry. This present work consists of a description of the activities carried through the Sectors of Radiation Therapy of the Hospital of Clinics of the Campinas State University (Unicamp), particularly in the implementation of the Quality Control Program

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The treatment of a tumor with ionizing radiation is an ongoing process with well differentiated stages. These ones include the tumor diagnosis and location, the decision on the treatment strategy, the absorbed dose planning and calculation, the treatment administration, the absorbed dose verification and the evaluation of results in short and long terms. The quality of a radiotherapy procedure is closely linked to factors that may be classified as clinical, such as the diagnosis, the tumor location, the treatment strategy chosen and the continuous treatment reassessment; dosimetric or physical, such as the uncertainty in the dose calculation, its optimization and verification, the suitability of the equipment to provide a radiation beam consistent with the treatment planning; finally, others which are related to the practical application of radiotherapy treatment and the handling of the patient. In order to analyze the radiotherapy quality, one should realize that the three aspects (medical, physical or dosimetric and practical application) should be considered in a combined way. This means that numerous actions of the radiotherapists, medical physicists and technicians in radiotherapy should be held jointly and their knowledge level will significantly affect the treatment quality. In this study, the main physical parameters used in dosimetry are defined as well as determined experimentally for a linear accelerator Mevatron - MXT. With this, it is intended to provide recommendations for the physical aspects of Quality Assurance (QA) in the radiotherapy treatments, and these will usually be applied by professionals in Medical Physics. In addition to these instructions, it is recommended that additional texts are prepared to address in detail the clinical aspects of the treatments QA

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This graduate work approaches the study of Statistical Process Control - SPC, in a stage production of an industrial frame, aiming to use the tool of statistical process control (SPC) to assess the process capability. Where the process needs improvement as well not meet the specifications. Assessing the needs that the company needs to improve quality management, and the difficulties they present during the implementation of the CEP. The present study is to use the method of case study. The results are presented through study of the level of defects using Pareto diagrams and control chart by - (p) fraction defective, and checking the capacity and stability of the process using control charts and histograms XbarraR. The process demonstrated the need for improvements in process and quality management. At the end of the work are presented suggestions for improving the quality system of the company

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The fishery products are sources of protein of high biological value and an important component in a balanced diet. However, they are highly subject to deterioration, which represents a serious risk to public health. Thus, rigorous methods are needed for quality assurance of fish in all stages of the production chain. Traditionally, the Brazilian population does not have the habit of eating fish, although the country presents a great potential for aquaculture, which is underexploited. The consumption of fish is limited by socio-economic factors. Currently, the search for food security is a global trend. Thus, it is necessary to change the profile of the consumer, by offering a competitive and safe food. In this paper, we address issues related to quality, hygiene and health of fish

Relevância:

90.00% 90.00%

Publicador:

Resumo:

No ambiente competitivo em que as empresas estão inseridas, verifica-se um crescimento significativo da divulgação sobre a importância de uma gestão adequada, objetivando a manutenção de sua sustentação competitiva. As exigências de mercado fazem crescer continuamente a preocupação em implantar Sistemas de Gestão da Qualidade, não só no universo das grandes corporações, mas também das empresas prestadoras de serviços, como por exemplo, os laboratórios de ensaio. A Promulgação da Lei dos medicamentos Genéricos (LEI 9787), por meio da RDC 299/99 estabelece que os laboratórios possuem o dever de prestar serviços que atendam aos princípios fundamentais de gestão da qualidade analítica e de boas práticas de laboratório. Nesse contexto e visando a condução dos ensaios exigidos para o registro de medicamentos genéricos, a Rede Brasileira de Laboratórios Analíticos em Saúde teve sua origem. Dentre os requisitos estabelecidos pela REBLAS para habilitação de laboratórios na condução de ensaios de Equivalência Farmacêutica, é determinado que “o laboratório deve estabelecer, implementar e manter um Sistema da Qualidade apropriado ao escopo das suas atividades” (ANVISA, 2002). Assim, torna-se indispensável a existência de um Manual da Qualidade, ferramenta que descreve o Sistema de Gestão da Qualidade de acordo com a política e objetivos que são declarados pela organização, bem como um Manual de Segurança em Laboratório para a Unidade Operacional de Equivalência Farmacêutica da UNESP.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This graduate work approaches the study of Statistical Process Control - SPC, in a stage production of an industrial frame, aiming to use the tool of statistical process control (SPC) to assess the process capability. Where the process needs improvement as well not meet the specifications. Assessing the needs that the company needs to improve quality management, and the difficulties they present during the implementation of the CEP. The present study is to use the method of case study. The results are presented through study, and checking the capacity and stability of the process using control charts XbarraR. The process demonstrated the need for improvements in process and quality management. At the end of the work are presented suggestions for improving the quality system of the company

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)