15 resultados para Error control

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Grinding process is usually the last finishing process of a precision component in the manufacturing industries. This process is utilized for manufacturing parts of different materials, so it demands results such as low roughness, dimensional and shape error control, optimum tool-life, with minimum cost and time. Damages on the parts are very expensive since the previous processes and the grinding itself are useless when the part is damaged in this stage. This work aims to investigate the efficiency of digital signal processing tools of acoustic emission signals in order to detect thermal damages in grinding process. To accomplish such a goal, an experimental work was carried out for 15 runs in a surface grinding machine operating with an aluminum oxide grinding wheel and ABNT 1045 e VC131 steels. The acoustic emission signals were acquired from a fixed sensor placed on the workpiece holder. A high sampling rate acquisition system at 2.5 MHz was used to collect the raw acoustic emission instead of root mean square value usually employed. In each test AE data was analyzed off-line, with results compared to inspection of each workpiece for burn and other metallurgical anomaly. A number of statistical signal processing tools have been evaluated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To evaluate the velocity of canine retraction, anchorage loss and changes on canine and first molar inclinations using self-ligating and conventional brackets.Materials and Methods: Twenty-five adults with Class I malocclusion and a treatment plan involving extractions of four first premolars were selected for this randomized split-mouth control trial. Patients had either conventional or self-ligating brackets bonded to maxillary canines randomly. Retraction was accomplished using 100-g nickel-titanium closed coil springs, which were reactivated every 4 weeks. Oblique radiographs were taken before and after canine retraction was completed, and the cephalograms were superimposed on stable structures of the maxilla. Cephalometric points were digitized twice by a blinded operator for error control, and the following landmarks were collected: canine cusp and apex horizontal changes, molar cusp and apex horizontal changes, and angulation changes in canines and molars. The blinded data, which were normally distributed, were analyzed through paired t-tests for group differences.Results: No differences were found between the two groups for all variables tested.Conclusions: Both brackets showed the same velocity of canine retraction and loss of anteroposterior anchorage of the molars. No changes were found between brackets regarding the inclination of canines and first molars.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The problem of signal tracking, in the presence of a disturbance signal in the plant, is solved using a zero-variation methodology. A state feedback controller is designed in order to minimise the H-2-norm of the closed-loop system, such that the effect of the disturbance is attenuated. Then, a state estimator is designed and the modification of the zeros is used to minimise the H-infinity-norm from the reference input signal to the error signal. The error is taken to be the difference between the reference and the output signals, thereby making it a tracking problem. The design is formulated in a linear matrix inequality framework, such that the optimal solution of the stated control problem is obtained. Practical examples illustrate the effectiveness of the proposed method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A number of studies have analyzed various indices of the final position variability in order to provide insight into different levels of neuromotor processing during reaching movements. Yet the possible effects of movement kinematics on variability have often been neglected. The present study was designed to test the effects of movement direction and curvature on the pattern of movement variable errors. Subjects performed series of reaching movements over the same distance and into the same target. However, due either to changes in starting position or to applied obstacles, the movements were performed in different directions or along the trajectories of different curvatures. The pattern of movement variable errors was assessed by means of the principal component analysis applied on the 2-D scatter of movement final positions. The orientation of these ellipses demonstrated changes associated with changes in both movement direction and curvature. However, neither movement direction nor movement curvature affected movement variable errors assessed by area of the ellipses. Therefore it was concluded that the end-point variability depends partly, but not exclusively, on movement kinematics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes an approach of optimal sensitivity applied in the tertiary loop of the automatic generation control. The approach is based on the theorem of non-linear perturbation. From an optimal operation point obtained by an optimal power flow a new optimal operation point is directly determined after a perturbation, i.e., without the necessity of an iterative process. This new optimal operation point satisfies the constraints of the problem for small perturbation in the loads. The participation factors and the voltage set point of the automatic voltage regulators (AVR) of the generators are determined by the technique of optimal sensitivity, considering the effects of the active power losses minimization and the network constraints. The participation factors and voltage set point of the generators are supplied directly to a computational program of dynamic simulation of the automatic generation control, named by power sensitivity mode. Test results are presented to show the good performance of this approach. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The serological detection of antibodies against human papillomavirus (HPV) antigens is a useful tool to determine exposure to genital HPV infection and in predicting the risk of infection persistence and associated lesions. Enzyme-linked immunosorbent assays (ELISAs) are commonly used for seroepidemiological studies of HPV infection but are not standardized. Intra-and interassay performance variation is difficult to control, especially in cohort studies that require the testing of specimens over extended periods. We propose the use of normalized absorbance ratios (NARs) as a standardization procedure to control for such variations and minimize measurement error. We compared NAR and ELISA optical density (OD) values for the strength of the correlation between serological results for paired visits 4 months apart and HPV-16 DNA positivity in cervical specimens from a cohort investigation of 2,048 women tested with an ELISA using HPV-16 virus-like particles. NARs were calculated by dividing the mean blank-subtracted (net) ODs by the equivalent values of a control serum pool included in the same plate in triplicate, using different dilutions. Stronger correlations were observed with NAR values than with net ODs at every dilution, with an overall reduction in nonexplained regression variability of 39%. Using logistic regression, the ranges of odds ratios of HPV-16 DNA positivity contrasting upper and lower quintiles at different dilutions and their averages were 4.73 to 5.47 for NARs and 2.78 to 3.28 for net ODs, with corresponding significant improvements in seroreactivity-risk trends across quintiles when NARs were used. The NAR standardization is a simple procedure to reduce measurement error in seroepidemiological studies of HPV infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Substitution of fuzzy logic control in an electrical system normally controlled by proportional-integral frequency was studied and analyzed. A linear model of an electrical system, the concepts which govern the theory of fuzzy logic, and the application of this theory to systems control, are briefly presented. The methodology of fuzzy logic was then applied to develop a model for an electrical energy system. The results of the simulation demonstrated that fuzzy logic control eliminated the area frequency error and permitted that only the area experiencing an increase in charge responds to this variation. Based on the results, it is concluded that control based on fuzzy logic is simple, is easy to maintain, is of low cost, and can be used to substitute traditional velocity controllers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates both theoretically and experimentally the effect of the location and number of sensors and magnetic bearing actuators on both global and local vibration reduction along a rotor using a feedforward control scheme. Theoretical approaches developed for the active control of beams have been shown to be useful as simplified models for the rotor scenario. This paper also introduces the time-domain LMS feedforward control strategy, used widely in the active control of sound and vibration, as an alternative control methodology to the frequency-domain feedforward approaches commonly presented in the literature. Results are presented showing that for any case where the same number of actuators and error sensors are used there can be frequencies at which large increases in vibration away from the error sensors can occur. It is also shown that using a larger number of error sensors than actuators results in better global reduction of vibration but decreased local reduction. Overall, the study demonstrated that an analysis of actuator and sensor locations when feedforward control schemes are used is necessary to ensure that harmful increased vibrations do not occur at frequencies away from rotor-bearing natural frequencies or at points along the rotor not monitored by error sensors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last decades there was a great development in the study of control systems to attenuate the harmful effect of natural events in great structures, as buildings and bridges. Magnetorheological fluid (MR), that is an intelligent material, has been considered in many proposals of project for these controllers. This work presents the controller design using feedback of states through LMI (Linear Matrix Inequalities) approach. The experimental test were carried out in a structure with two degrees of freedom with a connected shock absorber MR. Experimental tests were realized in order to specify the features of this semi-active controller. In this case, there exist states that are not measurable, so the feedback of the states involves the project of an estimator. The coupling of the MR damper causes a variation in dynamics properties, so an identification methods, based on experimental input/output signal was used to compare with the numerical application. The identification method of Prediction Error Methods - (PEM) was used to find the physical characteristics of the system through realization in modal space of states. This proposal allows the project of a semi-active control, where the main characteristic is the possibility of the variation of the damping coefficient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper deals with the problem of establishing a state estimator for switched affine systems. For that matter, a modification on the Luenberger observer is proposed, the switched Luenberger observer, whose idea is to design one output gain matrix for each mode of the original system. The efficiency of the proposed method relies on a simplification on estimation error which is proved always valid, guaranteeing the estimation error to asymptotically converge to zero, for any initial state and switching law. Next, a dynamic output-dependent switching law is formulated. Then, design methodologies using linear matrix inequalities are proposed, which, to the authors's knowledge, have not yet been applied to this problem. Finally, observers for DC-DC converters are designed and simulated as application examples. © 2013 Brazilian Society for Automatics - SBA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Colombian Reference National Laboratory, GENES LTDA, have organized and coordinated for the past two years (2009 and 2010) the Quality Control Exercise for laboratories undertaking paternity, maternity and forensic tests with DNA markers. Twenty-two laboratories have participated in 2009, increasing the number to 27 in 2010. Laboratories in Colombia, Brazil, Ecuador, Peru, Dominican Republic and Panama have participated in these exercises. There have been some similarities in the two controls: A practical exercise, three blood samples on FTA cards were sent to each participating laboratory to be genotyped for DNA markers using the routine methodologies in their laboratories; theoretical exercises including optional and obligatory cases. For the theoretical exercises, the participating laboratories should calculate the partial and final PI or BRI (Biological Relationship Index or Paternity Index). Forty-nine and 52 markers were under consensus for 2009 and 2010, respectively, distributed in autosomal, Y and X chromosomes STR. With respect to 2008, 12 and 15 additional markers were under consensus for 2009 and 2010, respectively. The rate of reporting error was 2.9% in 2009 while in 2010, 4.7% error was reported. The Proficiency Test conducted through the Colombian National Reference Laboratory has become a useful tool for quality assurance of all Colombian laboratories and some of Latin America that do DNA testing to establish biological relationships and an excellent opportunity for ongoing training of experts from the region.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The number of electronic devices connected to agricultural machinery is increasing to support new agricultural practices tasks related to the Precision Agriculture such as spatial variability mapping and Variable Rate Technology (VRT). The Distributed Control System (DCS) is a suitable solution for decentralization of the data acquisition system and the Controller Area Network (CAN) is the major trend among the embedded communications protocols for agricultural machinery and vehicles. The application of soil correctives is a typical problem in Brazil. The efficiency of this correction process is highly dependent of the inputs way at soil and the occurrence of errors affects directly the agricultural yield. To handle this problem, this paper presents the development of a CAN-based distributed control system for a VRT system of soil corrective in agricultural machinery. The VRT system is composed by a tractor-implement that applies a desired rate of inputs according to the georeferenced prescription map of the farm field to support PA (Precision Agriculture). The performance evaluation of the CAN-based VRT system was done by experimental tests and analyzing the CAN messages transmitted in the operation of the entire system. The results of the control error according to the necessity of agricultural application allow conclude that the developed VRT system is suitable for the agricultural productions reaching an acceptable response time and application error. The CAN-Based DCS solution applied in the VRT system reduced the complexity of the control system, easing the installation and maintenance. The use of VRT system allowed applying only the required inputs, increasing the efficiency operation and minimizing the environmental impact.