9 resultados para EFFLUX PUMP
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Microbial biofilms are responsible for a variety of microbial infections in different parts of the body, such as urinary tract infections, catheter infections, middle-ear infections, gingivitis, caries, periodontitis, orthopedic implants, and so on. The microbial biofilm cells have properties and gene expression patterns distinct from planktonic cells, including phenotypic variations in enzymic activity, cell wall composition and surface structure, which increase the resistance to antibiotics and other antimicrobial treatments. There is consequently an urgent need for new approaches to attack biofilm-associated microorganisms, and antimicrobial photodynamic therapy (aPDT) may be a promising candidate. aPDT involves the combination of a nontoxic dye and low-intensity visible light which, in the presence of oxygen, produces cytotoxic reactive oxygen species. It has been demonstrated that many biofilms are susceptible to aPDT, particularly in dental disease. This review will focus on aspects of aPDT that are designed to increase efficiency against biofilms modalities to enhance penetration of photosensitizer into biofilm, and a combination of aPDT with biofilm-disrupting agents. © 2013 Informa UK Ltd.
Resumo:
Objective - Kidney dysfunction is a common complication after cardiac surgery. It occurs in 7 to 31% of the patients. The lowest haematocrit after cardiopulmonary bypass surgery (LHCT) has been identified as a risk factor for kidney dysfunction after cardiac surgery. The aim of this study is to determine whether different levels of haematocrit during cardiopulmonary bypass surgery are related to kidney dysfunction.Methods and results-A prospective study was conducted on consecutive adult patients undergoing myocardial revascularization. Preoperative renal function was assessed by baseline serum creatinine level (CrPre). Peak postoperative creatinine (CrPost) was defined as the highest daily in-hospital postoperative value. Peak fractional change in creatinine (% Delta Cr) was defined as the difference between the CrPre and CrePost represented as a percentage of the preoperative value. The LHTC was defined as the lowest recorded haematocrit prior to weaning from the initial pump run. A category variable was created for haematocrit based on the distribution of values. The category variable had the following cut-off points: less than 23%, 23.1 to 28% and greater than 28.1 %. Lowest haematocrit (26.62 +/- 4.15%), CPB (74.71 +/- 24.90 min), CrPre (1.23 +/- 0.37 mg/dl) and highest CrPost (1.52 +/- 0.47 mg/dl) data varied in near-normal fashion. Statistical significance has been observed in the < 23% lowest haematocrit group (CrIPOD and Cr5POD; P = 0.006) and the 23.1 28% lowest haematocrit level group (CrPre and Cr2POD; P = 0.047). CrPre and Cr5POD did not differ between groups (P > 0.05). The multiple linear regression model confirmed that the determinants for higher %Delta Cr were age, body surface area and preoperative serum creatinine level.Conclusion - The LHTC was not identified as a risk factor for kidney dysfunction after myocardial revascularization.
Resumo:
The primary excited state absorption processes relating to the (5)I(6) -> (5)I(7) 3 mu m laser transition in singly Ho(3+)-doped fluoride glass have been investigated in detail using time-resolved fluorescence spectroscopy. Selective laser excitation of the (5)I(6) and (5)I(7) energy levels established the occurrence of two excited state absorption transitions from these energy levels that compete with previously described energy transfer upconversion processes. The (5)I(7) -> (5)I(4) excited state absorption transition has peak cross sections at 1216 nm (sigma(esa)=2.8x10(-21) cm(2)), 1174 nm (sigma(esa)=1x10(-21) cm(2)), and 1134 nm (sigma(esa)=7.4x10(-22) cm(2)) which have a strong overlap with the (5)I(8) -> (5)I(6) ground state absorption. on the other hand, it was established that the excited state absorption transition (5)I(6) -> (5)S(2) had a weak overlap with ground state absorption. Using numerical solution of the rate equations, we show that Ho(3+)-doped fluoride fiber lasers employing pumping at 1100 nm rely on excited state absorption from the lowest excited state of Ho(3+) to maintain a population inversion and that energy transfer upconversion processes compete detrimentally with the excited state absorption processes in concentrated Ho(3+)-doped fluoride glass. (c) 2008 American Institute of Physics.
Resumo:
Os solos agrícolas podem atuar como dreno ou fonte de C atmosférico, dependendo do sistema de manejo adotado. Este estudo foi desenvolvido em experimento de longa duração (22 anos), durante o período de 30 dias do outono, com o objetivo de avaliar o impacto de sistemas de preparo de solo (preparo convencional-PC e plantio direto-PD) nas emissões de C-CO2 de um Latossolo Vermelho distrófico, em Cruz Alta, RS. As emissões de C-CO2 do solo foram avaliadas com câmaras dinâmica (Flux Chamber 6400-09, Licor) e estática (com captação em solução alcalina), imediatamente após a colheita da soja. A temperatura e a umidade do solo foram registradas, concomitantemente com as emissões de C-CO2, por meio de sensor de temperatura e TDR manual, respectivamente, integrantes do Licor-6400. Estimou-se que, em 30 dias, uma quantidade equivalente a menos de 30 % do C aportado pelos resíduos de soja foi emitida na forma de C-CO2. As emissões de C-CO2 no solo em PD foram similares às emissões do solo em PC, independentemente do tipo de câmara utilizada. Diferenças entre sistemas de preparo quanto à emissão de C-CO2, avaliadas com a câmara dinâmica, foram verificadas somente a curto prazo (leituras diárias), com o PD apresentando maiores emissões do que o PC no início do período experimental e menores no final. A câmara dinâmica foi mais eficiente do que a estática em captar as alterações das emissões de C-CO2 em função da variação da temperatura e a porosidade preenchida por água (PPA) no solo em PD, as quais explicaram 83 e 62 % das emissões de C-CO2, respectivamente. O fator Q10, que avalia a sensibilidade da emissão de C-CO2 à temperatura do solo, foi estimado em 3,93, indicando alta sensibilidade da atividade microbiana à temperatura do solo durante o outono. As emissões de C-CO2 registradas no solo em PD com a câmara estática foram correlacionadas às da câmara dinâmica, porém com valores subestimados em relação àquela notadamente nos maiores valores de fluxo. em condições de baixa temperatura e PPA, o preparo de solo induziu limitado incremento de emissão de C-CO2.
Resumo:
Stopping the increase of atmospheric CO2 level is an important task and information on how to implement adjustments on tillage practices could help lower Soil CO2 emissions would be helpful. We describe how rotary tiller use on a red latosol affected Soil CO2 efflux. The impact of changing blade rotation speed and rear shield position on soil CO2 efflux was investigated. Significant differences among treatments were observed up to 10 days after tillage. Cumulative CO2 efflux was as much as 40% greater when blade rotation of 216 rpm and a lowered rear shield was compared to blade rotation of 122 rpm and raised shield. This preliminary work suggests that adjusting rotary tiller settings could help reduce CO2 efflux close to that of undisturbed soil, thereby helping to conserve soil carbon in tropical environments. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Drying kinetics of tomato was studied by using heat pump dryer (HPD) and electric resistance dryers with parallel and crossed airflow. The performance of both systems was evaluated and compared and the influence of temperature, air velocity, and tomato type on the drying kinetics was analyzed. The use of HPD showed to be adequate in the drying process of tomatoes, mainly in relation to the conversion rate of electric energy into thermal energy. The heat pump effective coefficient of performance (COPHT,EF) was between 2.56 and 2.68, with an energy economy of about 40% when compared to the drying system with electric resistance. The Page model could be used to predict drying time of tomato and statistical analysis showed that the model parameters were mainly affected by drying temperature.
Resumo:
The possibility to install a getter vacuum pump and its feasible in the anode of a high-power klystron amplifier is investigated in order to decrease of the pressure in the gun and consequently increasing its lifetime. The study is conducted using a 1.3 GHz, 100 A and 240 kV high-power klystron with five reentrant coaxial cavities, assembled in a cylindrical drift tube 1.2 m long. This work takes into account the specific conductance of components of gun and all important gas sources, like the degassing of the drift tube, the cavity walls, the cathode, the anode, and the collector, as well the position and pumping speed of the getter vacuum pump in anode region. © 2006 IEEE.
Resumo:
Cardiopulmonary bypass (CPB) is often associated with renal dysfunction, as measured by plasma creatinine levels and hemodialysis rates. Aim. To compare creatinine clearance (CrCl), estimated with the Cockroft and Gault formula, between patients undergoing off-pump coronary artery bypass grafting (OPCAB) versus on-pump CABG (on-CAB). Material and methods. Between April 2008 and April 2009, 119 patients underwent coronary bypass graft surgery. Fifty-eight (58) of these patients underwent OPCAB while 61 had on-CAB. Creatinine clearance, plasma creatinine levels, and clinical outcome were compared between the groups. A creatinine clearance value of 50 mL/minute was accepted as the lowest limit of normal renal function. Results. There were two hospital deaths caused by sepses after pulmonary infection. Creatinine clearance (Preoperative OPCAB 73,64±33,72 x on-CAB 75,70±34,30mL/min; discharge OPCAB 75,73±35,07 x on-CAB 79,07±34,71 mL/ min; p=0,609), and creatinine levels (Preoperative OPCAB 1,04±0,38 x on-CAB 1,13±0,53 mg/dL; discharge OPCAB 1,12±0,79 x on-CAB 1,04±0,29mg/dL; p=0,407) did not show statistically inter-group differences. Conclusion. Deterioration in renal function is associated with higher rates of postoperative complications. No significant difference in CrCl could be demonstrated between the groups.
Hot spots, hot moments, and spatio-temporal controls on soil CO2 efflux in a water-limited ecosystem
Resumo:
Soil CO2 efflux is the primary source of CO2 emissions from terrestrial ecosystems to the atmosphere. The rates of this flux vary in time and space producing hot moments (sudden temporal high fluxes) and hot spots (spatially defined high fluxes), but these high reaction rates are rarely studied in conjunction with each other. We studied temporal and spatial variation of soil CO2 efflux in a water-limited Mediterranean ecosystem in Baja California, Mexico. Soil CO2 efflux increased 522% during a hot moment after rewetting of soils following dry summer months. Monthly precipitation was the primary driver of the seasonal trend of soil CO2 efflux (including the hot moment) and through changes in soil volumetric water content (VWC) it influenced the relationship between CO2 efflux and soil temperature. Geostatistical analyses showed that the spatial dependence of soil CO2 efflux changed between two contrasting seasons (dry and wet). During the dry season high soil VWC was associated with high soil CO2 efflux, and during the wet season the emergence of a hot spot of soil CO2 efflux was associated with higher root biomass and leaf area index. These results suggest that sampling designs should accommodate for changes in spatial dependence of measured variables. The spatio-temporal relationships identified in this study are arguably different from temperate ecosystems where the majority of soil CO2 efflux research has been done. This study provides evidence of the complexity of the mechanisms controlling the spatio-temporal variability of soil CO2 efflux in water-limited ecosystems. (C) 2014 Elsevier Ltd. All rights reserved.