48 resultados para E. Wallace
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Using the exclusive decay B-s(0)-->J/psi(mu(+)mu(-))phi(K+K-), we report the most precise single measurement of the B-s(0) lifetime. The data sample corresponds to an integrated luminosity of approximately 220 pb(-1) collected with the D0 detector at the Fermilab Tevatron Collider in 2002-2004. We reconstruct 337 signal candidates, from which we extract the B-s(0) lifetime, tau(B-s(0))=1.444(-0.090)(+0.098)(stat)+/-0.020(sys) ps. We also report a measurement for the lifetime of the B-0 meson using the exclusive decay B-0-->J/psi(mu(+)mu(-))K-*0(892)(K(+)pi(-)). We reconstruct 1370 signal candidates, obtaining tau(B-0)=1.473(-0.050)(+0.052)(stat)+/-0.023(sys) ps, and the ratio of lifetimes, tau(B-s(0))/tau(B-0)=0.980(-0.071)(+0.076)(stat)+/-0.003(sys).
Resumo:
The DO experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid -argon calorimeters and central muon detector, remaining from Run 1, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of software specific to DO. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Correlations in the azimuthal angle between the two largest transverse momentum jets have been measured using the D0 detector in p (p) over bar collisions at a center-of-mass energy root s=1.96 TeV. The analysis is based on an inclusive dijet event sample in the central rapidity region corresponding to an integrated luminosity of 150 pb(-1). Azimuthal correlations are stronger at larger transverse momenta. These are well described in perturbative QCD at next-to-leading order in the strong coupling constant, except at large azimuthal differences where contributions with low transverse momentum are significant.
Resumo:
We report the observation of the X(3872) in the J/psipi(+)pi(-) channel, with J/psi decaying to mu(+)mu(-), in p (p) over bar collisions at roots=1.96 TeV. Using approximately 230 pb(-1) of data collected with the Run II D0 detector, we observe 522+/-100 X(3872) candidates. The mass difference between the X(3872) state and the J/psi is measured to be 774.9+/-3.1(stat)+/-3.0(syst) MeV/c(2). We have investigated the production and decay characteristics of the X(3872) and find them to be similar to those of the psi(2S) state.
Resumo:
A search for pair production of doubly charged Higgs bosons in the process p (p) over bar -->H++H---->mu(+)mu(+)mu(-)mu(-) is performed with the D0 run II detector at the Fermilab Tevatron. The analysis is based on a sample of inclusive dimuon data collected at an energy of roots=1.96 TeV, corresponding to an integrated luminosity of 113 pb(-1). In the absence of a signal, 95% confidence level mass limits of M(H-L(+/-+/-))>118.4 GeV/c(2) and M(H-R(+/-+/-))>98.2 GeV/c(2) are set for left-handed and right-handed doubly charged Higgs bosons, respectively, assuming 100% branching into muon pairs.
Resumo:
We report the results of a search for supersymmetry (SUSY) with gauge-mediated breaking in the missing transverse energy distribution of inclusive diphoton events using 263 pb(-1) of data collected by the D0 experiment at the Fermilab Tevatron Collider in 2002-2004. No excess is observed above the background expected from standard model processes, and lower limits on the masses of the lightest neutralino and chargino of about 108 and 195 GeV, respectively, are set at the 95% confidence level. These are the most stringent limits to date for models with gauge-mediated SUSY breaking with a short-lived neutralino as the next-to-lightest SUSY particle.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A photocatalyst based on CuO/SiO2 was prepared, and evaluated for the degradation of methylene blue in aqueous medium. The photocatalyst was obtained by calcination method of copper salt, in the presence of silica. The characterization by XRD, FTIR, and TPR techniques confirmed the formation of CuO as active phase. SEM studies showed CuO deposited on the surface of SiO2. By ESI-MS, it was demonstrated that the degradation of methylene blue occurs through successive hydroxylations. Photodegradation assays showed that CuO/SiO2 was efficient for degradation, and that the material worked better in the presence of UV light.
Resumo:
Background Some children with juvenile idiopathic arthritis either do not respond, or are intolerant to, treatment with disease-modifying antirheumatic drugs, including anti-tumour necrosis factor (TNF) drugs. We aimed to assess the safety and efficacy of abatacept, a selective T-cell costimulation modulator, in children with juvenile idiopathic arthritis who had failed previous treatments.Methods We did a double-blind, randomised controlled withdrawal trial between February, 2004, and June, 2006. We enrolled 190 patients aged 6-17 years, from 45 centres, who had a history of active juvenile idiopathic arthritis; at least five active joints; and an inadequate response to, or intolerance to, at least one disease-modifying antirheumatic drug. All 190 patients were given 10 mg/kg of abatacept intravenously in the open-label period of 4 months. of the 170 patients who completed this lead-in course, 47 did not respond to the treatment according to predefined American College of Rheumatology (ACR) paediatric criteria and were excluded. of the patients who did respond to abatacept, arthritis, and 62 were randomly assigned to receive placebo at the same dose and timing. The primary endpoint was time to flare of arthritis. Flare was defined as worsening of 30% or more in at least three of six core variables, with at least 30% improvement in no more than one variable. We analysed all patients who were treated as per protocol. This trial is registered, number NCT00095173.Findings Flares of arthritis occurred in 33 of 62 (53%) patients who were given placebo and 12 of 60 (20%) abatacept patients during the double-blind treatment (p=0.0003). Median time to flare of arthritis was 6 months for patients given placebo (insufficient events to calculate IQR); insufficient events had occurred in the abatacept group for median time to flare to be assessed (p=0.0002). The risk of flare in patients who contined abatacept was less than a third of that for controls during that double-blind period (hazard ratio 0.31, 95% CI 0.16-0.95). During the double-blind period, the frequency of adverse events did not differ in the two treatment groups, Adverse events were recorded in 37 abatacept recipients (62%) and 34 (55%) placebo recipients (p=0.47); only two serious adverse events were reported, bouth in controls (p=0.50).Interpretation Selective modulation of T-cell costimulation with abatacept is a rational alternative treatment for children with juvenile idiopathic arthritis.Funding Bristol-Myers Squibb.
Resumo:
This paper adresses the problem on processing biological data such as cardiac beats, audio and ultrasonic range, calculating wavelet coefficients in real time, with processor clock running at frequency of present ASIC's and FPGA. The Paralell Filter Architecture for DWT has been improved, calculating wavelet coefficients in real time with hardware reduced to 60%. The new architecture, which also processes IDWT, is implemented with the Radix-2 or the Booth-Wallace Constant multipliers. Including series memory register banks, one integrated circuit Signal Analyzer, ultrasonic range, is presented.