53 resultados para Dominant frequencies

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abnormal intragastric distribution of food (IDF) and a phasic contractility in the proximal stomach have been related to dyspeptic symptoms. Thus, the behaviour of the stomach and the proximal region, in particular, continues to attract attention and demand for reliable and comfortable techniques. The aims of this study were to employ AC Biosus-ceptometry (ACB) and scintigraphy to evaluate IDF and gastric motor activity in humans. Fifteen healthy volunteers ingested 60 mL of yogurt containing 2 mCi of Tc-99m and 4 g of ferrite. Each volunteer had gastric motility and IDF evaluated twice on separate days; on one occasion by ACB and another by scintigraphy. Digital signal processing was performed in MatLab (Mathworks Inc., Natick, MA, USA). Results were expressed as mean +/- SD. Similar results of distal accumulation time (P < 0.001) were obtained for scintigraphy (6.93 +/- 3.25 min) and for ACB (7.04 +/- 3.65 min). Fast Fourier Transform revealed two dominant frequencies (P > 0.9). Besides the well-know frequency of 3 cpm, our results showed identical frequencies in proximal stomach recordings (P < 0.001) for scintigraphic (1.01 +/- 0.01 cpm) and ACB (0.98 +/- 0.06 cpm). In summary, our data showed that scintigraphy and ACB are promising techniques to evaluate several aspects of gastric motility. Moreover, ACB is non-invasive, radiation-free and deserves the same importance as conventional methods for this kind of analysis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Successful application of shallow seismic reflection method is related directly to the ability of the ground to transmit high-frequency seismic energy from a seismic source. The dominant frequencies of reflection data are in the range of 50 to 100 Hz and depend on the surface materials and water table. A spread of geophones send the siemsic signal to be recorded on a 12, 24 or 48 channel portable seismograph, using a single high-frequency geophone per channel. Although it is possible to find seismographs with display and processing unities, it is also possible to transfer digitalized data to a personal computer to be processed and interpreted by using specific programs. Some results of two recent field studies to specify the underground structure in the tidal flats area of Baie St. Paul (Quebec-Canada) and in glacial terrains, in the Waterloo (Ontario-Canada) region. -from English summary

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study is to analyze the vocalizations of Dendropsophus nanus and its responses to the dominant frequencies of conspecific calls. There were made playback experiments by broadcasting calls of different dominant frequencies towards particular individuals, while their behavioral responses were registered. The results suggest that the playbacks cause behavioral complexity and aggressiveness to increase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After removal of the Selective Availability in 2000, the ionosphere became the dominant error source for Global Navigation Satellite Systems (GNSS), especially for the high-accuracy (cm-mm) demanding applications like the Precise Point Positioning (PPP) and Real Time Kinematic (RTK) positioning.The common practice of eliminating the ionospheric error, e. g. by the ionosphere free (IF) observable, which is a linear combination of observables on two frequencies such as GPS L1 and L2, accounts for about 99% of the total ionospheric effect, known as the first order ionospheric effect (Ion1). The remaining 1% residual range errors (RREs) in the IF observable are due to the higher - second and third, order ionospheric effects, Ion2 and Ion3, respectively. Both terms are related with the electron content along the signal path; moreover Ion2 term is associated with the influence of the geomagnetic field on the ionospheric refractive index and Ion3 with the ray bending effect of the ionosphere, which can cause significant deviation in the ray trajectory (due to strong electron density gradients in the ionosphere) such that the error contribution of Ion3 can exceed that of Ion2 (Kim and Tinin, 2007).The higher order error terms do not cancel out in the (first order) ionospherically corrected observable and as such, when not accounted for, they can degrade the accuracy of GNSS positioning, depending on the level of the solar activity and geomagnetic and ionospheric conditions (Hoque and Jakowski, 2007). Simulation results from early 1990s show that Ion2 and Ion3 would contribute to the ionospheric error budget by less than 1% of the Ion1 term at GPS frequencies (Datta-Barua et al., 2008). Although the IF observable may provide sufficient accuracy for most GNSS applications, Ion2 and Ion3 need to be considered for higher accuracy demanding applications especially at times of higher solar activity.This paper investigates the higher order ionospheric effects (Ion2 and Ion3, however excluding the ray bending effects associated with Ion3) in the European region in the GNSS positioning considering the precise point positioning (PPP) method. For this purpose observations from four European stations were considered. These observations were taken in four time intervals corresponding to various geophysical conditions: the active and quiet periods of the solar cycle, 2001 and 2006, respectively, excluding the effects of disturbances in the geomagnetic field (i.e. geomagnetic storms), as well as the years of 2001 and 2003, this time including the impact of geomagnetic disturbances. The program RINEX_HO (Marques et al., 2011) was used to calculate the magnitudes of Ion2 and Ion3 on the range measurements as well as the total electron content (TEC) observed on each receiver-satellite link. The program also corrects the GPS observation files for Ion2 and Ion3; thereafter it is possible to perform PPP with both the original and corrected GPS observation files to analyze the impact of the higher order ionospheric error terms excluding the ray bending effect which may become significant especially at low elevation angles (Ioannides and Strangeways, 2002) on the estimated station coordinates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new static model for tubular fluorescent lamps (T12 bulb) operated at high frequencies. The main goal of this paper is to investigate the effects of ambient temperature and nominal switching frequency of operation in the static characteristics of tubular fluorescent lamps. The methodology for obtaining the model is based on several two-dimensional mathematical regressions, used to provide the behavior of the fluorescent lamp according to different independent variables, namely: power processed through the lamp and ambient temperature. In addition, the proposed model can be easily converted to a lamp equivalent resistance model, which can be useful for ballast designers. Finally, the curves obtained using the new model are compared to the correspondent experimental data, in order to verify the accuracy of the proposed methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies have suggested that hepatitis C virus (HCV) may infect not only hepatocytes but may also be carried by platelets. Platelets express more than 20 polymorphic antigenic determinants on their surface, which are called human platelet antigens (HPA), To determine the allele frequency of the HPA-1 to -5 in patients infected with HCV, blood samples were collected from 257 blood donors for the control group and from 191 patients infected with HCV. DNA was isolated and amplified for genes HPA-1 to -4 using PCR Sequence Specific Primers (PCR-SSP) and HPA-5 using PCR-Restriction Fragment Length Polymorphism (PCR-RFLP). The allelic and genotypic frequency of HPA-5a in patients infected with HCV was found to be significantly lower(P < 0.05) than in the controls, and HPA-5b from patients infected with HCV was significantly higher (P < 0.05) than in controls. The increase in HPA5b allelic frequency in HCV infection may indicate a possible association between HCV infection and HPAs. J. Med. Virol. 81:757-759, 2009. (C) 2009 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We found evidence of autosomal dominant hereditary transmission of sulcus vocalis. Four dysphonic patients from three generations of the same family were submitted to videolaryngoscopic examination (three patients) and to direct laryngoscopy ( one patient) to diagnose the hoarseness. Sulcus vocalis was diagnosed in all four patients. The finding of four affected individuals in three generations, with vertical transmission affecting man and women, is more consistent with autosomal dominant inheritance pattern; it is an etiological model that we propose for the sulcus vocalis in this pedigree.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Avaliou-se o desempenho de tilápias-do-nilo (Oreochromis niloticus) produzidas em tanque-rede, providas de dispensadores automáticos de ração, alimentadas em diferentes frequências - uma vez por hora e a cada duas horas - e períodos - durante o dia, à noite ou ambos. Dezoito tanques-rede de 1.0m³ foram colocados em um tanque de 2000m² com dois metros de profundidade e renovação de água de 5%. Cento e setenta tilápias, com peso inicial de 16.0±4.9g foram distribuídas em cada tanque-rede de 1m³ e a taxa alimentar foi ajustada a cada 21 dias junto com as biometrias. As medidas foram coletadas de março a julho (outono e inverno). Observou-se diferença significativa para peso final (P<0.05) entre os tratamentos. O aumento da frequência alimentar melhorou o desempenho produtivo de tilápias-do-nilo produzidas em tanque-rede e permitiu melhor manejo alimentar. A melhor conversão alimentar para alta frequência, 24 vezes dia-1, pode resultar em uma economia de até 360kg de ração por tonelada de peixe produzido, melhorando a sustentabilidade econômica para produção de tilápia e sugerindo menor poluição ambiental.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reproductive efficiency is not optimal in high-producing dairy cows. Although many aspects of ovarian follicular growth in cows are similar to those observed in heifers, there are numerous specific differences in follicular development that may be linked with changes in reproductive physiology in high-producing lactating dairy cows. These include: I) reduced circulating estradiol (E2) concentrations near estrus, 2) ovulation of follicles that are larger than the optimal size, 3) increased double ovulation and twinning, and 4) increased incidence of anovulation with a distinctive pattern of follicle growth in anovular dairy cows. The first three changes become more dramatic as milk production increases, although anovulation has not generally been associated with level of milk production. To overcome reproductive inefficiencies in dairy cows, reproductive management programs have been developed to synchronize ovulation and enable the use of timed AI in lactating dairy cows. Effective regulation of the CL, follicles, and hormonal environment during each part of the protocol is critical for optimizing these programs. This review discusses the distinct aspects of follicular development in lactating dairy cows and the methodologies that have been utilized in the past two decades in order to manage the dominant follicle during synchronization of ovulation and timed AI programs. (C) 2011 Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)