27 resultados para Document imaging system
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Aim: This in vitro study evaluated the accuracy of primary incisor lengths determined by digital and conventional radiography compared to the actual tooth length. Methods: Twenty extracted primary maxillary incisors were mounted in acrylic blocks. Tooth length was estimated by using a straight-line measurement provided by the distance measurement tool of a digital dental imaging system (Computed Dental Radiography, Schick Technologies Inc.) and conventional E-speed film radiographs by using a digital caliper. Two operators familiar with both radiographic methods performed the estimates. The estimated tooth lengths were compared to the actual tooth lengths measured with the digital caliper. Data were statistically analyzed by Dahlberg's equation, paired t test, Pearson's correlation coefficient and ANOVA at 5% significance level. Results: There were no statistically significant differences (p = 0.85) between tooth length estimated on digital and conventional radiographs. Admitting as clinically acceptable a 0.5-mm discrepancy between the actual tooth lengths and the radiographically estimated lengths, 60% of the radiographic measurements were considered as accurate. When the acceptable difference range was 1.0 mm, the accuracy of the radiographic measurements increased to 100%. Conclusions: Digital and conventional radiography provided similar tooth length measurements and were equivalent to the actual tooth lengths.
Resumo:
Aims: This multi-centre analysis assessed the DNA content of TSCC in 37 young patients (<40 years) and 28 old patients (>50 years) and determined the correlation of DNA ploidy findings with clinicopathological data.Methods and results: Image cytometry was carried out using an automated cellular imaging system on Feulgen-stained histological sections to obtain high-fidelity DNA histograms. Among young patients, 37.8% were females compared to 18.7% in the older group (P = 0.002). In total, 48.6% patients were non-smokers and 40.5% were non-drinkers compared to 10.7% non-smokers and non-drinkers in the older group (P < 0.0001). TNM, clinical stage of disease and histological grade of differentiation did not differ between groups. Tumour aneuploidy was detected in 86.5% and tetraploidy in 24.3% young patients; this was significantly greater than in the older group where 64.3% were aneuploid (P < 0.0001) and 7.2% tetraploid (P < 0.0001). The mean values of DNA index (DI) and DNA heterogeneity index as well as the percentage of cells with DI exceeding 5N were higher in young patients (P < 0.0001).Conclusions: Young patients with TSCC represent a distinct clinical entity. The high incidence of DNA ploidy abnormalities suggest that they may have increased genomic instability and indicates underlying genetic differences between TSCC in young and older patients.
Resumo:
Purpose: the purpose of this in vivo study was to compare the accuracy of primary incisor length determined by direct digital radiography (straight-line measurement and grid superimposition) and measurement of the actual tooth length. Methods. Twenty-two primary maxillary incisors that required extractions were selected from 3- to 5-year-old children. The teeth were radiographed with an intraoral sensor using the long cone technique and a sensor holder (30-cm focus-to-sensor distance). The exposure time was 03 seconds. Tooth length was estimated by using straight-line and grid measurements provided by the distance measurement feature of the Computed Dental Radiography digital dental imaging system. The actual tooth length was obtained by measuring the extracted tooth with G digital caliper. Data were analyzed statistically by Pearson's correlation coefficient and a paired t test. Results: There were statistically significant differences (P=.007) between the 2 measurement techniques and between the actual tooth lengths and grid measurements. There was no statistically significant difference (P=38) between straight-line measurements and actual tooth lengths, showing that the straight-line measurements were more accurate. Underestimation of the actual tooth length, however, occurred in 45% of the straight-line measurements and in 73% of the grid measurements. Conclusion: It is possible to determine primary tooth length in digital radiographs using onscreen measurements with 0 reasonable degree of accuracy.
Resumo:
The aim of this study was to evaluate the effect of radiotherapy on the radiopacity and flexural strength of composite resin. Forty Z250 composite resin specimens were polymerized using a halogen light-curing unit and divided into 5 groups, in accordance with the radiotherapy dose: G1- without irradiation, G2- 30 Gy, G3- 40 Gy, G4- 50 Gy and GS- 60 Gy Digital images were obtained using a GE 100 X-ray. Radiopacity values were obtained with the Digora digital imaging system and the flexural strength was evaluated with an EMIC universal testing machine. Data were submitted to ANOVA and Tukey 's test. G1 presented the highest radiopacity value, followed by G3, G5, G4 and G2. For flexural strength, G1 presented the lowest value, followed by G2, G5, G3 and G4. Differences were no significant (p>0.05). The commonly used dosage of radiotherapy treatment, did not cause alteration in the radiopacity and flexural strength of resin-based composites.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The fierce competitiveness of the current market and the sophistication of customer requirements made the commitment to quality a need within organizations. The search for quality has been carried out by the adoption of quality management systems, a formal organization that should be present throughout the organization, from the initial identification of market needs to the satisfaction of customer requirements. The methodology most commonly used for this purpose is based on the requirements of ISO 9001, latest version of 2008. Considering this scenario, was developed a case study in a small company of the industrial sector with the development of a plan for the implementation of ISO 9001. The proposed methodology involved the construction of a theoretical framework on the subject and the development of a case study with a qualitative approach. Initially, was applied a questionnaire to the representative of the organization about the company's operating procedures, activity logs held, current documentation, planning and resource management for the construction of an assessment about the adequacy of the company needs to ISO 9001. Were obtained as results the characterization of production processes and organizational structure of the company and examples of policy and objectives of quality, performance indicators, document control, system for visualization of non-compliances, among others. Finally, the benefits of adopting a quality management system based on ISO 9001 requirements for the company and its environmental issues such as increased process efficiency, less waste and greater profitability, were pointed out, and the conditions for effective certification in the future
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
P>AimTo compare the efficacy of different digital radiographic imaging systems for determining the length of endodontic files.MethodologyK-type endodontic files were introduced into the canals of 40 extracted human permanent single-rooted teeth and fixed in place at random lengths. The teeth were radiographed using Digora Optime (R), CygnusRay MPS (R) and CDR Wireless (R) digital imaging systems. Six observers measured every file length in all the images and repeated this procedure in 50% of the image samples, and assigned a score to the level of difficulty found. Analysis of variance for differences between digital systems and Tukey's test were performed. The level of intraobserver agreement was measured by intraclass correlation. The assigned scores were evaluated by Kruskal-Wallis and Dunn's tests.ResultsThe CDR Wireless values did not differ significantly from the actual lengths and the CygnusRay MPS values. The Digora Optime system was significantly different from the others and overestimated the values (P < 0.05). The Digora Optime was significantly easier to use for taking measurements and the CygnusRay MPS the most difficult (P < 0.05). All digital radiographic imaging systems showed excellent agreement with the Intraclass Correlation Coefficient > 0.95.ConclusionsThe three digital radiographic imaging systems were precise. The CDR Wireless system was significantly more accurate in determining endodontic file lengths, and similarly to Digora Optime, was considered the least difficult to use when assessing endodontic file lengths.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)