152 resultados para Disinfected impressions

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This in vitro study evaluated the dimensional accuracy of two impression techniques (tapered and splinted) with two stock trays (plastic and metal) for implant-supported prostheses. Materials and Methods: A master cast with four parallel abutment analogs and a passive framework were fabricated. Polyvinyl siloxane impression material was used for all impressions with two metal stock trays and two plastic stock trays (closed and open trays). Four groups (tapered plastic, splinted plastic, tapered metal, and splinted metal) and a control group (master cast) were tested (n = 5 for each group). After the framework was seated on each of the casts, one abutment screw was tightened, and the marginal gap between the abutment and framework on the other side was measured with a stereomicroscope. The measurements were analyzed with the Kruskal-Wallis one-way analysis of variance on ranks test followed by the Dunn method. Results: The mean values (+/- standard deviations) for the abutment/framework interface gaps were: master cast, 32 +/- 2 mu m; tapered metal, 44 +/- 10 mu m; splinted metal, 69 +/- 28 mu m; tapered plastic, 164 +/- 58 mu m; splinted plastic, 128 +/- 47 mu m. No significant difference was detected between the master cast, tapered metal, and splinted metal groups or between the tapered and splinted plastic groups. Conclusions: In this study, the rigidity of the metal stock tray ensured better results than the plastic stock tray for implant impressions with a high-viscosity impression material (putty). Statistically similar results were obtained using tapered impression copings and splinted squared impression copings. The tapered impression copings technique and splinted squared impression copings technique with a metal stock tray produced precise casts with no statistically significant difference in interface gaps compared to the master cast. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:544-550.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to investigate the level of microstrain that is exerted during polymerization of acrylic resins used for splinting during implant impressions. Material and Methods: Two acrylic resins (GC Pattern Resin, Duralay II) and square transfer coping splinting methods were evaluated by means of strain gauge analysis. Two implants were embedded in a polyurethane block, and the abutments were positioned. Sixty specimens were prepared using two square transfer Copings that were rigidly connected to each other using the acrylic resins. The specimens were randomly divided into three groups of 20 each for the splinting methods: Method 1 was a one-piece method; in method 2, the splint was separated and reconnected after 17 minutes; and in method 3, the splint was separated and reconnected after 24 hours. In each group, half the specimens were splinted with GC Pattern Resin and the other half were splinted with Duralay II. Three microstrain measurements were performed by four strain gauges placed on the upper surface of the polyurethane blocks at 5 hours after resin polymerization for all groups. The data were analyzed statistically. Results: Both resin type and splinting method significantly affected microstrain. interaction terms were also significant. Method 1 in combination with Duralay II produced significantly higher microstrain (1,962.1 mu epsilon) than the other methods with this material (method 2: 241.1 mu epsilon; method 3: 181.5 mu epsilon). No significant difference was found between splinting methods in combination with GC Pattern Resin (method 1: 173.8 mu epsilon; method 2: 112.6 mu epsilon; method 3: 105.4 mu epsilon). Conclusions: Because of the high microstrain generated, Duralay II should not be used for one-piece acrylic resin splinting, and separation and reconnection are suggested. For GC Pattern Resin, variations in splinting methods did not significantly affect the microstrain created. Int J Oral Maxillofac Implants 2012;27:341-345

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The accuracy of impressions that transfer the relationship of the implant to the metal framework of the prosthesis continues to be a problem. This study was designed to evaluate the accuracy of the transfer process under variable conditions with regard to implant analog angulations, impression materials, and techniques. Replicas (n = 60) of a metal matrix (control) containing four implants at 90°, 80°, 75°, and 65° in relation to the horizontal surface were obtained by using three impression techniques: T1 - indirect technique with conical copings in closed trays; T2 - direct technique with square copings in open trays; and T3 - square copings splinted with autopolymerizing acrylic resin; and four elastomers: P-polysulfide; I-polyether; A-addition silicone; and Z-condensation silicone. The values of the implant analog annulations were assessed by a profilometer to the nearest 0.017°, then submitted to analysis of variance for comparisons at significance of 5% (P < .05). For implant analog at 90°, the material A associated with T2 and material Z with T3 behaved differently (P < .05) from all groups. At 80°, all materials behaved differently (P < .01) with T1. At 75°, when T1 was associated, materials P and A showed similar behavior, as well as materials I and Z; however, P and A were different from I and Z (P < .01). When T3 was associated, all experimental groups behaved differently among them (P < .01). At 65°, the materials P and Z behaved differently (P < .01) from the control group with T1, T2, and T3; the materials I and A behaved differently from the control group (P < .01) when T1 and T2, respectively, were associated. The more perpendicular the implant analog annulation is in relation to the horizontal surface, the more accurate the impression. The best materials were material I and A and the most satisfactory technique was technique 3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the biosecurity measures adopted in dental prosthesis laboratories of the city of João Pessoa, PB, Brazil with respect to prosthetic works sent by dentists. Method: Twenty-five dental prosthesis technicians (DPT) of the city of João Pessoa, PB, filled out a questionnaire referring to their knowledge of the biosecurity principles, disinfection of impressions and other prosthetic items, and the use of individual protection equipment (IPE). Results: Although 92% of the interviewees believed in the possible occurrence of cross-infection between dental prosthesis laboratories and dental offices, 64% declared that the prosthetic works received in their laboratories do not undergo any disinfection procedure. It was also observed that, for disinfection of impressions and stone casts, the chemical substances are not used as recommended by the manufacturers or are innocuous to microorganisms. Regarding the use of IPE, 60% of the DPT used mask, but only 4% used gowns. With respect to the measures taken regarding the impressions received from dental offices, 56% of the interviewees only wash them in running tap water, and 56% of the stone casts that arrive at the laboratory are not disinfected in any way. Conclusion: There is a need for more motivation and instructions to DPT regarding the prevention of cross-contamination during sending and receiving of prosthetic works between dental prosthesis laboratories and dental offices because the DPT evaluated in this study were found negligent with respect to disinfection procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research aimed at studying the oxidation process, to verify the effectiveness of coliform inactivation and to evaluate the formation of ozonation disinfection byproducts (DBP) in anoxic sanitary wastewater treated with ozone/hydrogen peroxide applied at doses of 2.6 mg O3 L-1 and 2.0 mg H2O2 L-1 with contact time of 10 min and 8.1 mg O3 L-1 and 8.0 mg H2O2 L-1 with contact time of 20 min. The mean chemical oxygen demand (COD) reductions were 7.50 and 9.40% for applied dosages of 2.5-2.8 and 6.4-9.4 mg O3 L-1 + 2.0 and 8.0 mg H2O2.L-1, respectively. The Escherichia coli (E. coli) inactivation range was 2.98-4.04 log10 and the total coliform inactivation range was 2.77-4.01 log10. The aldehydes investigated were formaldehyde, acetaldehyde, glyoxal and methylglyoxal. It was observed only the formation of acetaldehyde that ranged 5.53 to 29.68 μg L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cares at the manipulation of the alginate (condensation, disinfection of the impression and the time elapsed until the leak of the plaster) deserve special attention considering the great amount of distortions occurring every time the impression is not fill of plaster in a brief space of time and appropriate storage conditions. Besides its adaptation to the plaster suffers influence of the events happened after the impression is removed of the mouth. The purpose of this research was to evaluate the wetting capacity of three brands of alginate (Jeltrate™,Hydrogum™ e Orthoprint™) by the plaster type III (Rio™) under the influence of disinfection by sodium hypochlorite 1% sprays and the time of storage of 15 minutes,30 minutes, 1 hour, 6, 12 and 24 hours. There were made 60 impressions of each brand of alginate divided in two groups (water and sodium hypochlorite 1%) rearranged after the application of the sodium hypochlorite spray according to the storage time (15 or 30 minutes and 1,6,12, or 24 hours). On the surface of the impressions 2ml of plaster were flowed, proportioned and condensed in agreement with manufacturer‘s instructions. After the final setting expansion the casts were sectioned vertically and medially, regularized at the cut surface (emery paper 400) and setted for reading the contact angle at the microscope Carl Zeiss. The obtained results, submitted to statistical treatment (ANOVA) revealed significant differences when compared the employed solutions (water and sodium hypochlorite 1%) and the time of storage. The sodium hypochlorite 1% exhibited the smallest contact angles and the times of storage of 15 minutes and 6 hours the smallest and larger angles, respectively. It can be concluded that the alginate impressions exhibited larger adaptation to the plaster when disinfected by hypochlorite of sodium 1% and stocked by 15 minutes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Foram utilizados frutos de goiabeiras das cultivares Pedro Sato e Paluma, provenientes de pomar comercial, no estádio de maturação de vez, correspondente à coloração verde-mate e considerados ótimo para o consumo. Os frutos foram inicialmente imersos em solução de hipoclorito de sódio (150mg de cloro.L-1) por 5 minutos, para desinfecção superficial. Pessoas treinadas, utilizando proteção adequada e equipamentos desinfetados descascaram os frutos, cortaram-nos longitudinalmente ao meio e eliminaram a polpa com as sementes, em ambiente a 12°C. Após enxágüe com água clorada (20mg de cloro.L-1) foram embalados em contentores de tereftalato de polietileno (PET) com tampa. Estas unidades foram armazenadas a 3°C por 10 dias. Foram realizadas análises microbiológicas ao longo do período. Determinaram-se quimicamente os conteúdos de lignina, ácido ascórbico, acidez total titulável, sólidos solúveis totais e porcentagem de solubilização das pectinas, bem como as variáveis sensoriais de textura, sabor e preferência. A textura tornou-se mais frágil e os conteúdos de ácido ascórbico se reduziram, ao longo do período de armazenamento, nos produtos de ambas as cultivares. Durante este período houve aumento no conteúdo de lignina e manutenção dos conteúdos de sólidos solúveis totais (SST), acidez total titulável (ATT) e da relação SST/ATT. O produto da cultivar Pedro Sato apresentou menor perda de textura que o da 'Paluma', sendo considerado pelos provadores como o mais saboroso e, portanto, o mais preferido. Devido aos cuidados higiênicos tomados durante o processamento o produto apresentou baixa contagem microbiana (< 10³ UFC.g-1), em todas as avaliações efetuadas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente trabalho teve como objetivo avaliar o efeito do tipo de preparo (rodelas e metades) e da temperatura de armazenamento (3ºC, 6ºC e 9ºC) na conservação de produto minimamente processado de abacaxi-'Pérola'. Os frutos, depois de selecionados, lavados e desinfectados com cloro, foram armazenados por 12 horas a 10ºC, antes de serem processados sob condições higiênicas, embalados em contentores de polietileno tereftalatado (rodelas) ou bandeja de isopor recoberta com filme de cloreto de polivinila esticável (metades) e armazenados por até 12 dias. Os produtos foram avaliados quanto à evolução da atmosfera interna na embalagem, respiração, quantidade de suco drenado e evolução da massa fresca e da aparência. Foram testadas, durante o período de armazenamento, a aceitabilidade pelos consumidores, no início do experimento e enquanto a aparência e a análise microbiológica permitiram. A presença de bactérias mesofílicas e coliformes totais e fecais foi avaliada a cada três dias. Durante o armazenamento, a porcentagem de O2 nas embalagens apresentou decréscimo, enquanto a de CO2 aumentou até 20% para as metades e até 1,86% para as rodelas. A intensidade dos cortes no preparo teve influência direta na respiração, assim como nas perdas de suco e de massa fresca. A temperatura influenciou na respiração e foi fator limitante à vida de prateleira do produto, pois os produtos armazenados a 9ºC, conservaram-se por 6 dias, enquanto os mantidos a 3ºC e 6ºC, por até 9 dias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar, física e quimicamente, produtos minimamente processados de abacaxi-'Pérola', rodelas e metades, armazenados sob diferentes temperaturas (3ºC, 6ºC e 9ºC). Frutos selecionados, quanto ao grau de maturação e ausência de danos, foram lavados, desinfeccionados com cloro (200 mg.L-1) e armazenados a 10ºC, por 12 horas, antes do processamento. O produto minimamente processado foi embalado em bandejas de isopor recobertas com filme de PVC esticável (metades) ou bandejas de tereftalato de polietileno (rodelas) e armazenado sob refrigeraç ;ão, com avaliação a cada 3 dias, quanto à textura, coloração, pH, e conteúdos de sólidos solúveis totais, acidez total titulável, ácido ascórbico e de açúcares, solúveis e redutores. Durante o armazenamento, o produto tornou-se menos firme, e sua polpa apresentou escurecimento. Os conteúdos de açúcares solúveis e redutores e de sólidos solúveis totais não foram afetados pelo tipo de preparo, temperatura ou embalagem. Os teores de acidez total titulável aumentaram e foram influenciados pela temperatura, sendo que os mantidos a 9ºC apresentaram os maiores teores, havendo, como conseqüência, decréscimo no pH. Os produtos armazenados a 9ºC também apresentaram evolução mais rápida no escurecimento, na redução do teor de ácido ascórbico e menor vida útil (6 dias), enquanto, para os armazenados a 3ºC e 6ºC, este período foi de 9 dias. Os resultados obtidos permitiram concluir que a temperatura de armazenamento foi o fator limitante para a vida útil destes produtos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O trabalho teve como objetivo avaliar os aspectos qualitativos de uvas de mesa apirênicas (sem sementes) quando submetidas ao processamento mínimo e armazenadas sob refrigeração. Para tanto, foram utilizadas uvas da cultivar BRS Morena e da Seleção Avançada nº 8, produzidas na Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA) Uva e Vinho/Estação Experimental de Viticultura Tropical (da Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA) de Jales). Os cachos, depois de higienizados, imersos em água clorada a 300 mg de cloro.L-1 por 5 min., foram mantidos em câmara fria, a 12ºC, por 12 h. Pessoas treinadas e com proteção adequada procederam à degrana dos cachos e ao posterior enxágüe das bagas com água clorada (20 mg.L-1) a 12ºC. Depois de escorrido o excesso de água, as bagas foram acondicionadas em bandejas de tereftalato de polietileno (PET) transparente com tampa e com capacidade para 500 mL. Cada unidade, contendo 200 g de bagas, foi armazenada a 2,5 ± 1ºC e 88% UR por até 36 dias. Avaliaram-se a perda de massa fresca, a evolução da aparência, a coloração e os teores de sólidos solúveis totais (SST), e de acidez titulável (AT). Nas condições do experimento, os produtos minimamente processados da cv. BRS Morena e da Seleção 8 apresentaram baixa perda acumulada de massa fresca (0,16%). O produto da cv. Morena apresentou-se mais escuro (L = 25,04) e mais arroxeado (h° = 332,88) que o da Seleção 8 (L = 29,86 e h° = 345,11), propiciando-lhe melhor qualidade visual. O suco da 'BRS Morena' apresentou maiores teores de SST (22,17 °Brix) e menores para a AT (0,56 %), o que resultou em uma relação SST/AT maior e melhor (39,76) que o da Seleção 8 (18,81). A cv. BRS Morena também apresentou boa manutenção da aparência e, portanto, da qualidade comercial, por 33 dias a 2,5°C, superior ao obtido para a Seleção 8 (24 dias).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar a qualidade de produtos minimamente processados de mamão 'Formosa', fatias ou metades, armazenados sob diferentes temperaturas (3ºC, 6ºC e 9ºC). Utilizou-se de frutos que, depois de selecionados quanto ao grau de maturação e ausência de danos, foram lavados, desinfeccionados com cloro (200 mg.L-1) e armazenados a 12ºC, por 12 horas antes do processamento, que foi feito manualmente, a 12ºC. Os mamões, depois de descascados, foram cortados em fatias (5,0 x 2,5 cm) ou em metades longitudinais sem as pontas, que, depois de enxaguadas com água sanitizada (20 mg de cloro.L-1) e escorridas por 2-3 minutos, foram embaladas em bandejas de isopor recobertas com filme de PVC esticável (metades) ou em bandejas de tereftalato de polietileno - PET (fatias) e imediatamente armazenadas sob refrigeração. A avaliação destes produtos foi feita a cada 3 dias, quanto à resistência da polpa, coloração, pH e conteúdos de sólidos solúveis, acidez titulável, ácido ascórbico e de carboidratos, solúveis e de redutores. Durante o armazenamento, as fatias tenderam a se tornarem mais firmes, com a sua polpa apresentando pequeno escurecimento. Os conteúdos de carboidratos solúveis e de redutores e de sólidos solúveis não foram afetados pelo tipo de corte, temperatura de armazenamento ou embalagem. Durante o armazenamento, os teores de acidez titulável aumentaram nas fatias e diminuíram nas metades e observou-se influência da temperatura. Não se observaram reduções nos teores de ácido ascórbico durante o armazenamento, ou influência dos cortes ou das embalagens. Os produtos mantiveram-se adequados para comercialização até o 10º dia de armazenamento.