27 resultados para Density Measurement

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a theoretical analysis of a density measurement cell using an unidimensional model composed by acoustic and electroacoustic transmission lines in order to simulate non-ideal effects. The model is implemented using matrix operations, and is used to design the cell considering its geometry, materials used in sensor assembly, range of liquid sample properties and signal analysis techniques. The sensor performance in non-ideal conditions is studied, considering the thicknesses of adhesive and metallization layers, and the effect of residue of liquid sample which can impregnate on the sample chamber surfaces. These layers are taken into account in the model, and their effects are compensated to reduce the error on density measurement. The results show the contribution of residue layer thickness to density error and its behavior when two signal analysis methods are used. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An ultrasonic density-measurement cell is experimentally characterized as a function of temperature. The measurement of propagation velocity and density of several liquids is performed in the 15 degrees C-40 degrees C temperature range. Results are compared to the tabulated values in the case of distilled water, showing an accuracy of 0.07% for the propagation velocity. The cell was tested with distilled water, alcohol, and homogenized milk, and density values are compared to those obtained with a pycnometer, showing 0.2% accuracy in density measurement for stabilized temperature and 0.4% accuracy under thermal gradient conditions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Em 12 fêmeas e 12 machos da raça Puro Sangue Inglês com idade média de 12 meses, avaliou-se os valores normais da densidade mineral óssea do carpo acessório em milímetros de alumínio (mmAl) até o momento do fechamento completo da epífise distal do rádio, por meio do método de densitometria óptica em imagens radiográficas. A avaliação foi realizada por meio de um programa computacional (software) especialmente desenvolvido para medida de densidade óptica em filmes de raios-X, o qual contém a imagem radiográfica do osso carpo acessório, região de partes moles adjacente ao carpo acessório e os degraus de uma escala de alumínio (phatom), que permitiu a medida de densidade mineral óssea, sendo esta a média aritmética da região de interesse determinada no osso carpo acessório correspondente ao valor em milímetros da escala. Os valores da densidade mineral óssea em mmAl do acessório do carpo em função da idade não apresentaram diferenças entre os sexos (p=0,86) permitindo que uma equação de reta fosse ajustada para ambos os sexos (densidade mineral óssea (DMO) mmAl = 3.109 + 0,056 x idade em meses), na faixa etária estudada.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work presents recent improvements in a density measurement cell with a double-element transducer that can eliminate diffraction effects. A new mechanical design combined with the use of more appropriate materials has resulted in better parallelism between interfaces, more robust assembly, and chemical resistance. A novel method of signal processing, named energy method, is introduced to obtain the reflection coefficient, reducing sensitivity to noise and improving accuracy. The measurement cell operation is verified both theoretically, using an acoustic wave propagation model, and experimentally, using homogeneous liquids with different densities. The accuracy in the density measurement is 0.2% when compared with the measurements made with a pycnometer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes the use of a large-aperture PVDF receiver in the measurement of liquid density and composite material elastic constants. The density measurement of several liquids is obtained with accuracy of 0.2% using a conventional NDE emitter transducer and a 70-mm-diameter, 52-mu m P(VDF-TrFE) membrane with gold electrodes. The determination of the elastic constants is based on the phase velocity measurement. Diffraction can lead to errors around 1% in velocity measurement when using alternatively the conventional pair of ultrasonic transducers (1-MHz frequency and 19-mm-diameter) operating in through-transmission mode, separated by a distance of 100 mm. This effect is negligible when using a pair of 10-MHz, 19-mm-diameter transducers. Nevertheless, the dispersion at 10 MHz can result in errors of about 0.5%, when measuring the velocity in composite materials. The use of an 80-mm diameter, 52-mu m-thick PVDF membrane receiver practically eliminates the diffraction effects in phase velocity measurement. The elastic constants of a carbon fiber reinforced polymer were determined and compared with the values obtained by a tensile test. (C) 2009 Elsevier B. V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Eqüinos da raça Quarto de Milha, 30 machos e 30 fêmeas com idade entre 42 e 48 meses, apresentando a epífise distal do rádio fechada, em plena atividade esportiva, foram analisados quanto à densidade mineral óssea (DMO) do acessório do carpo, tendo os valores expressos em milímetros de alumínio (mmAl). As radiografias da estrutura óssea, juntamente com uma escala de alumínio (penetrômetro) foram analisadas por meio de um programa computacional, especialmente desenvolvido para medida da densidade óptica em imagem radiográfica. O valor médio encontrado para as fêmeas foi de 4,49±0,69mmAl, com idade média de 43±2 meses e, para os machos, de 4,43 ± 0,81mmAl, com idade média de 45±2 meses, não havendo diferença significativa na DMO entre os sexos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Composites containing a matrix of nanometric Ce-stabilized zirconia with an addition of micrometric monoclinic zirconia were processed by slip casting and sintered at a relatively low temperature. The ratio between nanometric and micrometric particles was determined according to the viscosity of the suspensions and the final density of the pellets. An optimum amount of micrometric particles was necessary to achieve improved suspension dispersion and higher pellet density. The amount of deflocculant in the suspensions containing the mixture of micrometric and nanometric particles was optimized by viscosity measurements. The pellets were characterized by dilatometry, Hg porosimetry, density measurement (the Archimedes method) and scanning electron microscopy. Despite the low green density obtained (35-38% of the theoretical density), densities as high as 97.5% were achieved after sintering. (C) 2001 Elsevier B.V. Ltd and Techna S.r.l. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sintering of SnO 2 compacts, obtained through slip casting, was studied by means of dilatometry, Hg porosimetry, scanning electron microscopy, and density measurement (Archimedes method). Sintering is strongly influenced by the green microstructure. Moreover, the sintering mechanisms are not dependent on the slurries' solid content up to 50% of solids in volume. Above this value, agglomerates are formed, leading to differential sintering inside and among the agglomerates. Another important point is the reduction of the temperature of maximum shrinkage rate when compared to tin oxide processed by isostatic pressing. This reduction is more accentuated when ammonium hydroxide is added to the suspension. (C) 2000 Published by Elsevier Science Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to verify the effect of Panicum maximum plant density on the initial growth of Eucalyptus grandis plants, one assay was conducted under semi-controlled conditions of soil fertility and humidity. Dark red Latossol, collected from the arable layer, was used as substrate in 50 liters amianthus cement boxes. One seedling of Eucalyptus was planted in each box. Fifteen days later, seedlings of P. maximum were transplanted on the same box. The treatments consisted of 0, 4, 8, 12, 16 and 20 plants of P. maximum per m 2. The experimental design was the complete randomized design, with six treatments and eight replicates for P. maximum. One hundred and ten and 190 days after transplanting, Eucalyptus plants grown among P. maximum showed an average reduction of 30.80 and 46.55% stem diameter, 25.10 and 22.50 plant high, 40.18 and 31.29% stem dry weight, 61.32 and 54.06% branch dry weight, 53.72 and 51.82% root dry weight, 44.62 and 38.50% leaf dry weight, 22.51 and 23.16 branch number, 20.72 and 19.97% leaf number, and 33.88 and 17.05% leaf area, respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An ultrasonic densitometer is experimentally characterized as a function of temperature. The measurement of propagation velocity and density of several liquids is performed in the 15 to 40°C temperature range. Results are compared to tabulated values in the case of distilled water, showing accuracy of 0.07% for the propagation velocity. Density values are compared to those obtained with a pycnometer, showing 0.2% accuracy in density measurement for stabilized temperature and 0.4% under thermal gradient conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to examine the endothelial surface and to perform a morphometric analysis of the corneal endothelial cells in normal eyes of dogs using specular microscopy. Morphometric analysis with regard mean cell area and cell density was performed. Both eyes of ten mixed-breed, males and females, with 6 years of age, weighing about 15 kg euthanatized for reasons unrelated to this study were evaluated. Eyes were examined to determine that they did not have visible ocular disease and transported to the laboratory in moist chamber. Using a contact specular microscope the corneal endothelium was examined. Three images of the central corneal endothelium of each eye were obtained. The mean cell area and the cell density of the corneal endothelial cells were obtained using software for corneal endothelium analysis and density measurement. The mean cell area was 395 ± 36 μm 2 and the endothelial cell density was 2555 ± 240 cells/mm2. The present work demonstrates that the normal corneal endothelium of dog is similar to those described in human.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The goal of this research was to determine the density distribution in medium density fiberboard (MDF), manufactured with polyurethane derived from castor oil using, ultrasonic wave technique. The equipment used in this test is Steinkamp BP7 with plan and exponential transducers, both with 45 kHz frequencies, located in several zones on the plate in order to determine wave ultrasonic velocity. The Pinus caribaea and Eucalyptus grandis fiberboard were manufactured in the quality control and products development laboratory of Duratex with 500 mm long, 500 mm large, 8 and 15 mm of thickness. Three MDF for each fiber specimen and thickness were fabricated, totalizing twelve plates tested. The MDF were produced with 5% polyurethane addition, in temperature of 160°C, tension press of 53 bars and addition of moisture content of 12%. For determination of fiberboard density, samples were extracted from the same zones where the wave ultrasonic velocity was determined. In this case, DAX-Ray equipment was used. Statistical analysis shows good agreement with wave ultrasonic velocity and the density profile, validating the application of non-destructive technique in order to determine the density profile of MDF's.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes the use of a large aperture PVDF receiver in the measurement of density of liquids and elastic constants of composite materials. The density measurement of several liquids is obtained with the accuracy of less than 0.2% using a conventional NDT emitter transducer and a 70-mm diameter, 52-μm P(VDF-TrFE) membrane with gold electrodes. The determination of the elastic constants of composite materials is based in the measurement of phase velocity. It is shown that the diffraction can lead to errors around 1% in the velocity measurement when using a pair of ultrasonic transducers (1MHz and 19mm diameter) operating in transmission-reception mode separated by a distance of 100 mm. This effect is negligible when using a pair of 10-MHz transducers. On the other hand, the dispersion at 10 MHz can result in errors of about 0.5%, measuring the velocity in composite materials. The use of an 80-mm diameter, 52-μm thick PVDF membrane receiver allows measuring the phase velocity without the diffraction effects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The increasing demand for devices for solid state applications in many technological areas has resulted in a high demand for new materials. Among these material have the advantage of being manufactured with different chemical compositions, and may have physical properties equal to or higher than the corresponding crystalline material. The aim of this paper was to produce borate glass system 50B2O3 – 15CuO – 20Li2O – 15X (X = Na2O, K2O, RbCl e Cs2O) to analyze the influence of the atomic radius of alkali in the physical properties of this glass system. The glasses were synthesized by the process of melting and molding. The characteristic temperatures were determined by the technique of scanning calorimetry (DSC). The non-crystalline was determined by x-ray diffraction. In order to determine the molar volume a density measurement by using the Archimedes method was used. The structural characterization was carried out using the technique of infrared spectroscopy