11 resultados para Critical Incident Technique
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objectives: The lack of durability in resin-dentine bonds led to the use of chlorhexidine as MMP-inhibitor to prevent the degradation of hybrid layers. Biomimetic remineralisation is a concept-proven approach in preventing the degradation of resin-dentine bonds. The purpose of this study is to examine the integrity of aged resin-dentine interfaces created with a nanofiller-containing etch-and-rinse adhesive after the application of these two approaches.Methods: The more established MMP-inhibition approach was examined using a parallel in vivo and in vitro ageing design to facilitate comparison with the biomimetic remineralisation approach using an in vitro ageing design. Specimens bonded without chlorhexidine exhibited extensive degradation of the hybrid layer after 12 months of in vivo ageing.Results: Dissolution of nanofillers could be seen within a water-rich zone within the adhesive layer. Although specimens bonded with chlorhexidine exhibited intact hybrid layers, water-rich regions remained in those hybrid layers and degradation of nanofillers occurred within the adhesive layer. Specimens subjected to in vitro biomimetic remineralisation followed by in vitro ageing demonstrated intrafibrillar collagen remineralisation within hybrid layers and deposition of mineral nanocrystals in nanovoids within the adhesive.Conclusions: The impact was realized by understanding the lack of an inherent mechanism to remove water from resin-dentine interfaces as the critical barrier to progress in bonding with the etch-and-rinse technique. The experimental biomimetic remineralisation strategy offers a creative solution for incorporating a progressive hydration mechanism to achieve this goal, which warrants its translation into a clinically applicable technique. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The marsh deer (Blastocerus dichotomus) is an endangered species froth the marshlands of central South America. Its population has declined in several regions due to the loss of available habitat caused by human activities, especially the construction of hydroelectric darns. The capture of individual deer is critical for research programs and population management. This report describes a novel live-capture technique, which uses a helicopter to drive the animals into a terrain that restricts their movement such as thick vegetation or deep water (60-120 cm in depth). Following confinement, animals are manually restrained. The short pursuit time (median = 2 thin), low mortality rate (0.82-3.28%), and the absence of injury to both the capture team and animals suggest that this method is appropriate for the safe capture of this species. Body temperature correlated with the pursuit time (R-2 = 0.15) but was not significantly altered with pursuit times <3 min.
Resumo:
Digital radiography in the inspection of welded pipes to be installed under deep water offshore gas and oil pipelines, like a presalt in Brazil, in the paper has been investigated. The aim is to use digital radiography for nondestructive testing of welds as it is already in use in the medical, aerospace, security, automotive, and petrochemical sectors. Among the current options, the DDA (Digital Detector Array) is considered as one of the best solutions to replace industrial films, as well as to increase the sensitivity to reduce the inspection cycle time. This paper shows the results of this new technique, comparing it to radiography with industrial films systems. In this paper, 20 test specimens of longitudinal welded pipe joints, specially prepared with artificial defects like cracks, lack of fusion, lack of penetration, and porosities and slag inclusions with varying dimensions and in 06 different base metal wall thicknesses, were tested and a comparison of the techniques was made. These experiments verified the purposed rules for parameter definitions and selections to control the required digital radiographic image quality as described in the draft international standard ISO/DIS 10893-7. This draft is first standard establishing the parameters for digital radiography on weld seam of welded steel pipes for pressure purposes to be used on gas and oil pipelines.
Resumo:
This paper presents a new single-phase interleaved high power factor boost pre-regulator operating in critical conduction mode, where the switches and boost diode performing zero-current commutations during its turn-off, eliminating the disadvantages related to the reverse recovery losses and electromagnetic interference problems of the boost diode, when operating in the continuous conduction mode. The interleaving technique is applied in the power cell, providing a significant input current ripple reduction in comparison to discontinuous mode of operation, due to its input current continuous conduction operation. This paper presents a complete modeling for the converter operating in critical conduction mode, resulting in an improved design procedure for interleaved techniques with high input power factor, a complete design procedure, and main simulation results from a design example with two interleaved cells rated at 1kW, 400V output voltage and 220V rms input voltage.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Majority of biometric researchers focus on the accuracy of matching using biometrics databases, including iris databases, while the scalability and speed issues have been neglected. In the applications such as identification in airports and borders, it is critical for the identification system to have low-time response. In this paper, a graph-based framework for pattern recognition, called Optimum-Path Forest (OPF), is utilized as a classifier in a pre-developed iris recognition system. The aim of this paper is to verify the effectiveness of OPF in the field of iris recognition, and its performance for various scale iris databases. This paper investigates several classifiers, which are widely used in iris recognition papers, and the response time along with accuracy. The existing Gauss-Laguerre Wavelet based iris coding scheme, which shows perfect discrimination with rotary Hamming distance classifier, is used for iris coding. The performance of classifiers is compared using small, medium, and large scale databases. Such comparison shows that OPF has faster response for large scale database, thus performing better than more accurate but slower Bayesian classifier.
Resumo:
This paper presents a new pre-regulator boost operating in the boundary area between the continuous and discontinuous conduction modes of the boost inductor current, where the switches and boost diode performing zero-current commutations during its turn-off, eliminating the disadvantages related to the reverse recovery losses and electromagnetic interference problems of the boost diode when operating in the continuous conduction mode. Additionally, the interleaving technique is applied in the power cell, providing a significant input current ripple reduction. It should be noticed that the main objective of this paper is to present a complete modeling for the converter operating in the critical conduction mode, allowing an improved design procedure for interleaved techniques with high input power factor, a complete dynamic analysis of the structure, and the possibility of implementing digital control techniques in closed loop.
Resumo:
A good catheter implantation technique is important to allow effective peritoneal access function and long-term technique survival. Studies regarding results obtained by nephrologists in comparison with different techniques have been limited. The aim of this study was to investigate the rate of early catheter-related complications and catheter survival in two Brazilian centers, according to two different percutaneous methods of catheter implantation performed by nephrologist team. Adult incident patients recruited from January 2006 to July 2013 having undergone first peritoneal dialysis (PD) catheter implantation were included in the analysis. Mechanical and infectious early complication rates were defined as time to the first event occurring up to 3 months. Four hundred and forty-five consecutive Tenckhoff catheters were implanted by nephrologist team percutaneously after antibiotic prophylaxis in an operating room: trocar was used in 349 (78.4 %) and Seldinger technique (ST) in 99 (21.6 %). The ST was significantly associated with a lower rate of leak (16.3 vs 3 %, p = 0.03) and outflow failure due to tip catheter migration (22.6 vs 10.1 %, p = 0.04), while early infectious complication rates were similar between the two groups (p = 0.59). Long-term catheter survival was higher in Seldinger group (log-rank, p = 0.031). By Cox multivariate analysis, adjusted for age, sex, and diabetes, the ST remained independently associated with better catheter survival [HR 0.681 (0.462-0.910), p = 0.04]. As conclusion, our experience showed better PD outcomes with the ST than trocar method of catheter implantation by nephrologist.
Resumo:
Maxillary canine impaction is a common occurrence, especially in the palate, despite sufficient space in the arch for tooth alignment. A proper approach requires knowledge of different specialties of dentistry, such as orthodontics, surgery, radiology, and periodontology, which are generally not centered on a single professional. The causes for canine impaction may be either generalized or localized, and the diagnosis should be made through specific clinical and radiographic examination. The prognosis of surgical-orthodontic treatment depends on the position of the canine in relation to the neighboring teeth and height of the alveolar process, in addition to careful surgical technique, considering that there are risks involved, such as ankylosis, loss of tooth vitality, root resorption of the involved tooth and adjacent teeth, and damage to supporting tissues. Given the important role played by impacted maxillary canines, their traction is the treatment of choice in orthodontically treated patients. The present study reviews the literature on important factors to be considered when approaching impacted canines, such as therapeutic possibilities, their advantages and disadvantages.