Resumo:
This work is devoted to Study and discuss the main methods to solve the network cost allocation problem both for generators and demands. From the presented, compared and discussed methods, the first one is based on power injections, the second deals with proportional sharing factors, the third is based upon Equivalent Bilateral Exchanges, the fourth analyzes the power How sensitivity in relation to the power injected, and the last one is based on Z(bus) network matrix. All the methods are initially illustrated using a 4-bus system. In addition, the IEEE 24-bus RTS system is presented for further comparisons and analysis. Appropriate conclusions are finally drawn. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
This paper addresses the problem of allocating the cost of the transmission network to generators and demands. A physically-based network usage procedure is proposed. This procedure exhibits desirable apportioning properties and is easy to implement and understand. A case study based on the IEEE 24-bus system is used to illustrate the working of the proposed technique. Some relevant conclusions are finally drawn.
Resumo:
O losartano potássico é um agente anti-hipertensivo não peptídico, que exerce sua ação por bloqueio específico dos receptores da angiotensina II. Este trabalho propôs a validação e aplicação de métodos analíticos orientados ao controle de qualidade de losartano potássico 50 mg na forma farmacêutica cápsula, utilizando a espectrofotometria direta e derivada de primeira ordem na região do UV. Baseado nas características espectrofotométricas de losartano potássico, um sinal a 205 nm do espectro de ordem zero e um sinal a 234 nm do espectro de primeira derivada foram adequados para a quantificação. Os resultados foram usados para comparar essas duas técnicas instrumentais. O coeficiente de correlação entre as respostas e as concentrações de losartano potássico na faixa de 3,0-7,0 mg L-1 e 6,0-14,0 mg L-1 para espectrofotometria direta e derivada de primeira ordem em solução aquosa, respectivamente, foi de (r) of 0,9999 para ambos os casos. Os métodos foram aplicados para quantificação de losartano potássico em cápsulas obtidas de farmácias de manipulação locais e demonstraram ser eficientes, fáceis de aplicar e de baixo custo. Além disso, não necessitam de reagentes poluentes e requerem equipamentos economicamente viáveis.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Low flexibility and reliability in the operation of radial distribution networks make those systems be constructed with extra equipment as sectionalising switches in order to reconfigure the network, so the operation quality of the network can be improved. Thus, sectionalising switches are used for fault isolation and for configuration management (reconfiguration). Moreover, distribution systems are being impacted by the increasing insertion of distributed generators. Hence, distributed generation became one of the relevant parameters in the evaluation of systems reconfiguration. Distributed generation may affect distribution networks operation in various ways, causing noticeable impacts depending on its location. Thus, the loss allocation problem becomes more important considering the possibility of open access to the distribution networks. In this work, a graphic simulator for distribution networks with reconfiguration and loss allocation functions, is presented. Reconfiguration problem is solved through a heuristic methodology, using a robust power flow algorithm based on the current summation backward-forward technique, considering distributed generation. Four different loss allocation methods (Zbus, Direct Loss Coefficient, Substitution and Marginal Loss Coefficient) are implemented and compared. Results for a 32-bus medium voltage distribution network, are presented and discussed.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper considers the congestion effects on emission and consumers' allocated cost. In order to consider some environmental and operational effects of congestion, an environmental constrained active-reactive optimal power flow (AROPF) considering capability curve is presented. On outage conditions, the total cost of the system will increase. On the other hand in power systems, the operating cost and system emission have conflicted objectives, then it may be concluded that the outage in the system may lead to a total emission decrease. In this paper the famous Aumann-Shapley method is used as a pricing methodology. Two case studies such as 14-bus and US-bus IEEE test systems are conducted. Results demonstrate that, although the line outage in power systems leads to increase the total cost, the amount of emission depending on the place where the outage occurs can be more than, less than or equal to the normal conditions' emission. Also results show that although from power sellers' standpoint the well-known Aumann-Shapley method is a precise pricing method to cover the incurred cost with an acceptable error that can show the real effect of congestion on consumers' cost, from consumers' standpoint it is not a good method for cost allocation, because some consumers will face with an increase in cost and the others will face with a decrease on their cost.
Resumo:
Infecções por Haemonchus spp. são uma das principais causas de perda econômica nas criações de ruminantes devido à redução no ganho de peso e mortalidade de bovinos e pequenos ruminantes, especialmente em regiões com clima tropical e subtropical. A identificação precisa das diferentes espécies, bem como o conhecimento sobre a epidemiologia das gastroenterites parasitárias, são fundamentais para a elaboração de estratégias sustentáveis de profilaxia das parasitoses. Essa revisão tem por objetivo central, abordar os principais métodos parasitológicos utilizados na identificação morfológica das espécies, os quais se caracterizam pela facilidade e baixo custo. Na maioria dos estudos realizados no Brasil, a distinção entre as espécies Haemonchus contortus e Haemonchus placei não tem sido considerada. Vários relatos de H. contortus, particularmente em bovinos, podem se tratar na verdade da infecção dos animais por H. placei. A identificação correta das espécies é, portanto, fundamental. Além das medidas dos espículos dos exemplares machos, outros detalhes morfológicos, tais como a sínlofe, devem ser avaliados com o objetivo de auxiliar na diferenciação das espécies. Mensurações das larvas infectantes, obtidas em coproculturas, podem também indicar a espécie de Haemonchus presente. Esse procedimento pode ser útil especialmente em estudos que não envolvem a necropsia de animais, como é o caso de testes destinados a avaliar a resistência anti-helmíntica em rebanhos.
Resumo:
Nowadays, networks must support applications such as: distance learning, electronic commerce, access to Internet, Intranets and Extranets, voice over IP (Internet Protocol) and many others. These new applications, employing data, voice, and video traffic, require high bandwidth and Quality of Service (QoS). The ATM (Asynchronous Transfer Mode) technology, together with dynamic resource allocation methods, offers network connections that guarantee QoS parameters, such as minimum losses and delays. This paper presents a system that uses Network Management Functions together with dynamic resource allocation for provision of the end-to-end QoS parameters for rt-VBR connections.
Resumo:
Since the 80s huge efforts have been made to utilize renewable energy sources to generate electric power. An important issue about using renewable energy sources is a Distribution Management System (DMS) in presence of dispersed generators. This paper reports some aspects of integration of the dispersed generators in the DMS. Besides, an investigation of impact of the dispersed generators on the overall performances of the distribution systems in steady state is performed. In order to observe losses in the distribution networks with dispersed generators, several loss allocation methods are applied. Results obtained from case study using IEEE test network, are presented and discussed. © 2003 IEEE.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Obtaining accurate estimates of the volume of stacked wood is important in view of the increasing value of wood as raw material. Therefore, the forest companies have become increasingly concerned about the methods currently used to convert cubic meters for stereo. In this context, emerged the need of optimizing the measurement process and accuracy of the volume of stacked wood. For this, companies have been testing methods with greater efficiency, speed and low operating cost. Existing methods made through approximate equations, and also by determining the conversion factor, called the stacking factor (Fe), are questioned, due to errors and inaccuracies. The use of digital photographs is an alternative method that would minimize operator intervention, allowing greater control and speed the process, thus eliminating part of the imprecision of the traditional method. The use of the method is viable, due to present an error of about 10% while traditional methods showed an error of 17%