153 resultados para Clearance
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this paper a non-isothermal two-phase model for oil-R134a refrigerant mixture flow is presented to predict the R134a leakage through the radial clearance of rolling piston compressors. The flow is divided in a liquid single-phase region and in a two-phase region, in which the homogeneous model is used to simulate the flow. The refrigerant leakage is determined using the mixture mass flow rate and the refrigerant mass fraction variation along the flow. The results are obtained for inlet pressures varying from 200 to 700 kPa, inlet temperatures ranging from 40 to 60 degrees C, and minimal clearances between 10 and 60 mu m. The results are firstly compared to existing isothermal model data, showing that there is a significant difference between the leakage flow rates predicted by isothermal and non-isothermal models. Finally, a useful general equation for compressor designers is proposed to calculate the refrigerant leakage for a large range of operation conditions. (C) 2012 Elsevier Ltd and IIR. All rights reserved.
Resumo:
Many studies have demonstrated the relationship between dialysis dose and survival. Global mortality is similar among men and women; however, the influence of dialysis dose in the survival could be more intensive between women. Therefore, we conduct an observational study to evaluate the gender-related impact of single pool Kt/V (spKt/V) on the survival of patients submitted to hemodialysis in a university hospital. We found that survival was lower in groups with spKt/V smaller than 1.2 than in those with Kt/V between 1.2 and 1.4. Among female patients, spKt/V smaller than 1.2 had a more adverse effect in survival than among men with a comparable Kt/V. Otherwise, among women, the dialysis dose had an impact in survival even with Kt/V greater than 1.4. Thus, fractional urea clearance more heavily influenced the survival of females than males in hemodialysis patients.
Resumo:
To investigate functional changes in Trypanosoma cruzi parasites induced during their interaction with the vertebrate host, we compared the blood clearance profiles of blood forms isolated from infected normal mice (Reg-Tc) or from infected mice immunodepressed after treatment with cyclophosphamide (Cy-Tc). Parasite blood numbers were measured at various time intervals in animals injected intravenously (i.v.) with 1-2 x 10(6) T. cruzi of either isolate. In the absence of added immune sera (spontaneous clearance), Reg-Tc and Cy-Tc were cleared from blood at similar rates. However, when acute immune mouse serum (Ac-IMS) was injected i.v. 2 min after inoculation of parasites, a significant proportion of Cy-Tc only was cleared from the blood an hour later, whereas Reg-Tc were not, their clearance profile being identical to that observed in mice injected with normal mouse serum. Cy-Tc susceptibility to Ac-IMS was not the result of a toxic effect of cyclophosphamide over T. cruzi as parasites recovered from animals immunodepressed by irradiation before infection were cleared similarly by acute serum. Contrary to Ac-IMS, chronic immune mouse serum induced similar rates of disappearance of Reg-Tc and Cy-Tc from blood. Our results suggest the occurrence of T. cruzi selection or modification during the acute phase, which leads to an increased parasite resistance to the clearance properties of acute-phase antibodies.
Pharyngeal clearance and pharyngeal transit time determined by a biomagnetic method in normal humans
Resumo:
Clearance and transit time are parameters of great value in studies of digestive transit. Such parameters are nowadays obtained by means of scintigraphy and videofluoroscopy, with each technique having advantages and disadvantages. In this study we present a new, noninvasive method to study swallowing pharyngeal clearance (PC) and pharyngeal transit time (PTT). This new method is based on variations of magnetic flux produced by a magnetic bolus passing through the pharynx and detected by an AC biosusceptometer (ACB). These measurements may be performed in a simple way. cause no discomfort. and do not use radiation. We measured PC in 8 volunteers (7 males and I female. 23-33 years old) and PTT in 8 other volunteers (7 males and I female. 21-29 years old). PC was 0.82 +/- 0.10 s (mean +/- SD) and PTT was 0.75 +/- 0.03 s. The results were similar for PC but longer for PTT than those determined by means of other techniques. We conclude that the biomagnetic method can be used to evaluate PC and PTT.
Resumo:
Unsteady flow of oil and refrigerant gas through radial clearance in rolling piston compressors has been modeled as a heterogeneous mixture, where the properties are determined from the species conservation transport equation coupled with momentum and energy equations. Time variations of pressure, tangential velocity of the rolling piston and radial clearance due to pump setting have been included in the mixture flow model. Those variables have been obtained by modeling the compression process, rolling piston dynamics and by using geometric characteristics of the pump, respectively. An important conclusion concerning this work is the large variation of refrigerant concentration in the oil-filled radial clearance during the compression cycle. That is particularly true for large values of mass flow rates, and for those cases the flow mixture cannot be considered as having uniform concentration. In presence of low mass flow rates homogeneous flow prevail and the mixture tend to have a uniform concentration. In general, it was observed that for calculating the refrigerant mass flow rate using the difference in refrigerant concentration between compression and suction chambers, a time average value for the gas concentration should be used at the clearance inlet.
Resumo:
Background: Smoking impairs mucociliary clearance and increases respiratory infection frequency and severity in subjects with and without smoking-related chronic lung diseases. Objective: This study evaluated the effects of smoking intensity on mucociliary clearance in active smokers. Methods: Seventy-five active smokers were grouped into light (1-10 cigarettes/day; n = 14), moderate (11-20 cigarettes/day; n = 34) and heavy smokers (≥21 cigarettes/day; n = 27) before starting a smoking cessation programme. Smoking behaviour, nicotine dependence, pulmonary function, carbon monoxide in exhaled air (exCO), carboxyhaemoglobin (COHb) and mucociliary clearance measured by the saccharin transit time (STT) test were all evaluated. An age-matched non-smoker group (n = 24) was assessed using the same tests. Results: Moderate (49 ± 7 years) and heavy smokers (46 ± 8 years) had higher STT (p = 0.0001), exCO (p < 0.0001) and COHb (p < 0.0001) levels compared with light smokers (51 ± 15 years) and non-smokers (50 ± 11 years). A positive correlation was observed between STT and exCO (r = 0.4; p < 0.0001), STT and cigarettes/day (r = 0.3, p = 0.02) and exCO and cigarettes/day (r = 0.3, p < 0.01). Conclusion: Smoking impairs mucociliary clearance and is associated with cigarette smoking intensity. Copyright © 2013 S. Karger AG, Basel.
Resumo:
O presente trabalho compara os resultados obtidos da depuração da creatinina endógena de pacientes encaminhados por solicitação médica, realizados pelo Setor de Bioquímica Clínica do CRD-NAC Unesp com protocolo do procedimento de depuração implantado na rotina laboratorial, que utiliza dados da creatinina de sangue e urina (amostra de 24 horas), com os resultados obtidos, para os mesmos pacientes, a partir das fórmulas de Cockcroft-Gault, MDRD simplificada e CDK-EPI, onde não se utiliza os valores obtidos na amostra de urina de 24 horas. E, a partir dessa análise, verifica em que casos o resultado do exame sem a amostra de urina de 24 horas correlaciona-se com o resultado da depuração da creatinina endógena realizado como procedimento de rotina e quais seriam as prováveis variáveis interferentes na aplicação destas fórmulas utilizadas em casos específicos, conforme a necessidade na avaliação clínica.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)